Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation

被引:77
作者
Goncalves, Alexandra [1 ,2 ]
Almeria, Carlos [1 ]
Marcos-Alberca, Pedro [1 ]
Feltes, Gisela [1 ]
Hernandez-Antolin, Rosana [1 ]
Rodriguez, Enrique [1 ]
Silva Cardoso, Jose C. [2 ]
Macaya, Carlos [1 ]
Luis Zamorano, Jose [1 ]
机构
[1] Univ Complutense, Hosp Clin San Carlos, Cardiovasc Inst, E-28040 Madrid, Spain
[2] Univ Porto, Sch Med, Dept Cardiol, P-4100 Oporto, Portugal
关键词
3D transthoracic echocardiography; Paravalvular aortic regurgitation; Transcatheter aortic valve implantation; Vena contracta; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VALVULAR REGURGITATION; EUROPEAN-ASSOCIATION; FOLLOW-UP; STENOSIS; AREA; RECOMMENDATIONS; FEASIBILITY; REPLACEMENT; EXPERIENCE;
D O I
10.1016/j.echo.2011.08.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Paravalvular aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is common, but the evaluation of its severity by two-dimensional (2D) transthoracic echocardiography (TTE) presents several constrains. The aim of this study was to assess the usefulness of a new methodology, using three-dimensional (3D) TTE, for better assessment of paravalvular AR after TAVI. Methods: Two-dimensional and 3D TTE was performed in 72 patients, 5 months after TAVI, using the X5-1 PureWave microbeamforming xMATRIX probe. The position and severity of the paravalvular AR jets were described using 2D and 3D TTE, and a model was designed for paravalvular AR systematic location description. Vena contracta width was measured using 2D transthoracic echocardiographic views, and the planimetry of the vena contracta was assessed after the perfect alignment plane was obtained using the multiplanar 3D transthoracic echocardiographic reconstruction tool. AR volume was calculated as the difference between 3D TTE-derived total left ventricular stroke volume and right ventricular stroke volume estimated using 2D TTE. Diagnostic efficiency for moderate AR was assessed using receiver operating characteristic curve analysis. Results: Forty-three patients (57.4%) presented with AR; 10 (13.3%) had central AR, and 33 (44.0%) had paravalvular AR jets. Vena contracta widths were similar between patients with moderate and mild AR (2.1 +/- 0.53 vs 1.9 +/- 0.16 mm, P = .16), but vena contracta planimetry was larger in patients with moderate AR than in those with mild AR (0.30 +/- 0.12 vs 0.09 +/- 0.07 cm(2), P = .001). Vena contracta planimetry on 3D TTE was better correlated with AR volume than vena contracta width on 2D TTE (Kendall's tau = 0.82 [P < .001] vs 0.66 [P < .001]). The areas under the receiver operating characteristic curves were 0.96 for vena contracta planimetry and 0.35 for vena contracta width. Conclusions: This study proposes an alternative methodology for paravalvular AR assessment after TAVI. Using vena contracta planimetry on 3D TTE, an accurate methodology for paravalvular AR jet evaluation and moderate AR classification is described. (J Am Soc Echocardiogr 2012;25:47-55.)
引用
收藏
页码:47 / 55
页数:9
相关论文
共 26 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Matthews, Peter B. ;
Ge, Liang ;
Guy, T. Sloane ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
ANNALS OF THORACIC SURGERY, 2009, 88 (06) :1857-1863
[3]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[4]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[5]   Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence [J].
Detaint, Delphine ;
Lepage, Laurent ;
Himbert, Dominique ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Iung, Bernard ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :821-827
[6]   QUANTITATIVE DOPPLER ASSESSMENT OF VALVULAR REGURGITATION [J].
ENRIQUEZSARANO, M ;
BAILEY, KR ;
SEWARD, JB ;
TAJIK, AJ ;
KROHN, MJ ;
MAYS, JM .
CIRCULATION, 1993, 87 (03) :841-848
[7]   Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: Usefulness and validation [J].
Fang, LG ;
Hsiung, MC ;
Miller, AP ;
Nanda, NC ;
Yin, WH ;
Young, MS ;
Velayudhan, DE .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (09) :775-781
[8]   Aortic regurgitation: disease progression and management [J].
Goldbarg, Seth H. ;
Halperin, Jonathan L. .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (05) :269-279
[9]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[10]   Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies [J].
Gutiérrez-Chico, JL ;
Zamorano, JL ;
de Isla, LP ;
Orejas, M ;
Almería, C ;
Rodrigo, JL ;
Ferreirós, J ;
Serra, V ;
Macaya, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (06) :809-813