Biophysical Markers of Suspected Preeclampsia, Fetal Growth Restriction and The Two Combined-How Accurate They Are?

被引:2
作者
Sharabi-Nov, Adi [1 ]
Tul, Natasa [2 ,3 ]
Kumer, Kristina [4 ,5 ]
Srsen, Tanja Premru [2 ,6 ]
Vodusek, Vesna Fabjan [6 ]
Fabjan, Teja [4 ]
Osredkar, Josko [2 ,4 ,5 ]
Nicolaides, Kypros H. [7 ]
Meiri, Hamutal [8 ]
机构
[1] Safed & Tel Hai Coll, Ziv Med Ctr, IL-13100 Tel Hai, Israel
[2] Univ Ljubljana, Fac Med, Vrazov Trg 2, Ljubljana 1000, Slovenia
[3] Womens Hosp Med Ctr, Precna Ulica 4, Postojna 6230, Slovenia
[4] Univ Med Ctr, Inst Clin Chem & Biochem, Njegoseva 4, Ljubljana 1000, Slovenia
[5] Univ Ljubljana, Fac Pharm, Askerceva Cesta 7, Ljubljana 1000, Slovenia
[6] Univ Med Ctr, Dept Perinatol, Div Obstet & Gynecol, Zaloska Cesta 2, Ljubljana 1000, Slovenia
[7] Kings Coll Hosp London, Fetal Med Res Inst, 16-20 Windsor Walk, London SE5 8BB, England
[8] TeleMarpe Ltd, 41 Beit El St, Tel Aviv, Israel
来源
REPRODUCTIVE MEDICINE | 2022年 / 3卷 / 02期
关键词
preeclampsia; MAP-mean arterial blood pressure (mm Hg); PI-uterine artery pulsatility index; RHI-reactive hyperemia index; AIX (%)-augmentation index (percent); Endo PAT; multiple regression; area under the Receiver Operation Characteristic curve (ROC); fetal growth restriction; MEAN ARTERIAL-PRESSURE; ENDOTHELIAL FUNCTION; PREGNANCY COMPLICATIONS; DOPPLER; BLOOD; WOMEN; PREDICTION; ETIOLOGY; ASPIRIN; WEIGHT;
D O I
10.3390/reprodmed3020007
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives-To conduct a secondary analysis of prediction accuracy of biophysical markers for suspected Preeclampsia (PE), Fetal Growth Restriction (FGR) and the two combined near delivery in a Slovenian cohort. Methods-This was a secondary analysis of a database of a total 125 Slovenian pregnant women attending a high-risk pregnancy clinic due to suspected PE (n = 31), FGR (n = 16) and PE + FGR (n = 42) from 28-39 weeks gestation and their corresponding term (n = 21) and preterm (PTD, n = 15) controls. Data for Mean Arterial blood Pressure (MAP) and Uterine artery pulsatility index (UtA PI) estimated by Doppler sonography were extracted from the database of patients who were tested at admission to the high-risk clinic with the suspected complications. The reactive hyperemia index (RHI), and the Augmentation Index (AIX%) were extracted from the patient database using measured values obtained with the assistance of the Endo PAT, a device set to measure the signal of the peripheral arterial tone (PAT) from the blood vessels endothelium. Linear regression coefficients, Box and Whisker plots, Area under the Curve (AUC) of receiver Operation Characteristic (ROC) curves, and multiple regression were used to assess the marker accuracy using detection rate (DR) and false-positive rate (FPR) and previously reported cut-offs for estimating the positive and negative predictive value (NPV and PPV). The SPSS non-parametric statistics (Kruskal Wallis and Mann-Whitney) and Spearman's regression coefficient were used to assess marker accuracy; p < 0.05 was considered significant. Results-MAP values reached diagnostic accuracy (AUC = 1.00, DR = 100%) for early PE cases delivered < 34, whereas UtA Doppler PI values yielded such results for early FGR < 34 weeks and the two combined reached such accuracy for PE + FGR. To reach diagnostic accuracy for all cases of the complications, the Endo PAT markers with values for MAP and UtA Doppler PI were required for cases near delivery. Multiple regression analyses showed added value for advanced maternal age and gestational week in risk assessment for all cases of PE, FGR, and PE + FGR. Spearman's regression coefficient yielded r > 0.6 for UtA Doppler PI over GA for PE and FGR, whereas for RHI over BMI, the regression coefficient was r > 0.5 (p < 0.001 for each). Very high correlations were also found between UtA Doppler PI and sFlt-1/PlGF or PlGF (r = -0.495, p < 0.001), especially in cases of FGR. Conclusion-The classical biophysical markers MAP and UtA Doppler PI provided diagnostic accuracy for PE and FGR < 34 wks gestation. A multiple biophysical marker analysis was required to reach diagnostic accuracy for all cases of these complications. The UtA Doppler PI and maternal serum sFlt-1/PlGF or PlGF were equally accurate for early cases to enable the choice of the markers for the clinical use according to the more accessible method.
引用
收藏
页码:62 / 84
页数:23
相关论文
共 59 条
  • [1] The Use of Sex-Specific Factors in the Assessment of Women's Cardiovascular Risk
    Agarwala, Anandita
    Michos, Erin D.
    Samad, Zainab
    Ballantyne, Christie M.
    Virani, Salim S.
    [J]. CIRCULATION, 2020, 141 (07) : 592 - 599
  • [2] Gestational Hypertension and Preeclampsia
    Espinoza, Jimmy
    Vidaeff, Alex
    Pettker, Christian M.
    Simhan, Hyagriv
    [J]. OBSTETRICS AND GYNECOLOGY, 2020, 135 (06) : E237 - E260
  • [3] [Anonymous], Managing Complications in Pregnancy and Childbirth
  • [4] Arrebola-Moreno AL, 2012, REV ESP CARDIOL, V65, P80, DOI [10.1016/j.rec.2011.10.004, 10.1016/j.recesp.2011.09.012]
  • [5] Accuracy of Blood Pressure Measurement Devices in Pregnancy A Systematic Review of Validation Studies
    Bello, Natalie A.
    Woolley, Jonathan J.
    Cleary, Kirsten Lawrence
    Falzon, Louise
    Alpert, Bruce S.
    Oparil, Suzanne
    Cutter, Gary
    Wapner, Ronald
    Muntner, Paul
    Tita, Alan T.
    Shimbo, Daichi
    [J]. HYPERTENSION, 2018, 71 (02) : 326 - 335
  • [6] Peripheral arterial tone: assessment of microcirculatory function in pregnancy
    Carty, David M.
    Anderson, Lesley A.
    Duncan, Catherine N.
    Baird, David P.
    Rooney, Laura K.
    Dominiczak, Anna F.
    Delles, Christian
    [J]. JOURNAL OF HYPERTENSION, 2012, 30 (01) : 117 - 123
  • [7] Diagnostic Accuracy of Placental Growth Factor in Women With Suspected Preeclampsia A Prospective Multicenter Study
    Chappell, Lucy C.
    Duckworth, Suzy
    Seed, Paul T.
    Griffin, Melanie
    Myers, Jenny
    Mackillop, Lucy
    Simpson, Nigel
    Waugh, Jason
    Anumba, Dilly
    Kenny, Louise C.
    Redman, Christopher W. G.
    Shennan, Andrew H.
    [J]. CIRCULATION, 2013, 128 (19) : 2121 - 2131
  • [8] Prediction of small for gestational age neonates: screening by maternal factors, fetal biometry, and biomarkers at 35-37 weeks' gestation
    Ciobanu, Anca
    Rouvali, Angeliki
    Syngelaki, Argyro
    Akolekar, Ranjit
    Nicolaides, Kypros H.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2019, 220 (05) : 486.e1 - 486.e11
  • [9] ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
    Salomon L.J.
    Alfirevic Z.
    Da Silva Costa F.
    Deter R.L.
    Figueras F.
    Ghi T.
    Glanc P.
    Khalil A.
    Lee W.
    Napolitano R.
    Papageorghiou A.
    Sotiradis A.
    Stirnemann J.
    Toi A.
    Yeo G.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (06) : 715 - 723
  • [10] Accuracy of mean arterial pressure and blood pressure measurements in predicting pre-eclampsia: systematic review and meta-analysis
    Cnossen, Jeltsje S.
    Vollebregt, Karlijn C.
    de Vrieze, Nynke
    ter Riet, Gerben
    Mol, Ben W. J.
    Franx, Arie
    Khan, Khalid S.
    van der Post, Joris A. M.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2008, 336 (7653): : 1117 - 1120