Optimizing Pulsed-Chemical Exchange Saturation Transfer Imaging Sequences

被引:102
作者
Zu, Zhongliang [2 ]
Li, Ke [2 ]
Janve, Vaibhav A. [3 ]
Does, Mark D. [2 ,4 ]
Gochberg, Daniel F. [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Med Ctr N, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
关键词
magnetic resonance imaging; chemical exchange magnetization transfer; pulsed-CEST; MAGNETIZATION-TRANSFER; CONTRAST AGENTS; MRI CONTRAST; QUANTITATIVE INTERPRETATION; PARACEST AGENTS; HUMAN BRAIN; CEST AGENT; IN-VIVO; MODEL;
D O I
10.1002/mrm.22884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical exchange saturation transfer (CEST) provides a new imaging contrast mechanism sensitive to labile proton exchange. Pulsed-CEST imaging is better suited to the hardware constraints on clinical imaging systems when compared with traditional continuous wave-CEST imaging methods. However, designing optimum pulsed-CEST imaging sequences entails complicated and time-consuming numerical integrations. In this work, a simplified and computationally efficient technique is provided to optimize the pulsed-CEST imaging sequence. An analysis was performed of the optimal average irradiation power and the optimal irradiation flip angle as a function of the acquisition parameters and sample properties in both a two-pool model and a three-pool model of endogenous amine exchange. Key simulated and experimental results based on a creatine/agar tissue phantom show that (1) the average irradiation power is a more meaningful sequence metric than is the average irradiation field amplitude, (2) the optimal average powers for continuous wave and pulsed-CEST imaging are approximately equal to each other for a relevant range of solute frequency offsets, exchange rates, and concentrations, (3) an irradiation flip angle of 180 degrees is optimal or near optimal, independent of the other acquisition parameters and the sample properties, and (4) higher duty cycles yield higher CEST contrast. Magn Reson Med 66: 1100-1108, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1100 / 1108
页数:9
相关论文
共 27 条
[1]  
Aime S, 2002, ANGEW CHEM INT EDIT, V41, P4334, DOI 10.1002/1521-3773(20021115)41:22<4334::AID-ANIE4334>3.0.CO
[2]  
2-1
[3]   Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications [J].
Aime, S ;
Barge, A ;
Delli Castelli, D ;
Fedeli, F ;
Mortillaro, A ;
Nielsen, FU ;
Terreno, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :639-648
[4]   A paramagnetic MRI-CEST agent responsive to lactate concentration [J].
Aime, S ;
Delli Castelli, D ;
Fedeli, F ;
Terreno, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (32) :9364-9365
[5]   QUANTITATIVE INTERPRETATION OF MAGNETIZATION-TRANSFER [J].
HENKELMAN, RM ;
HUANG, XM ;
XIANG, QS ;
STANISZ, GJ ;
SWANSON, SD ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :759-766
[6]   Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain [J].
Hua, Jun ;
Jones, Craig K. ;
Blakeley, Jaishri ;
Smith, Seth A. ;
van Zijl, Peter C. M. ;
Zhou, Jinyuan .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) :786-793
[7]   Amide proton transfer imaging of human brain tumors at 3T [J].
Jones, Craig K. ;
Schlosser, Michael J. ;
van Zijl, Peter C. M. ;
Pomper, Martin G. ;
Golay, Xavier ;
Zhou, Jinyuan .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) :585-592
[8]   Polymeric nanomedicine for cancer MR imaging and drug delivery [J].
Khemtong, Chalermchai ;
Kessinger, Chase W. ;
Gao, Jinming .
CHEMICAL COMMUNICATIONS, 2009, (24) :3497-3510
[9]   PARACEST MRI With Improved Temporal Resolution [J].
Liu, Guanshu ;
Ali, M. Meser ;
Yoo, Byunghee ;
Griswold, Mark A. ;
Tkach, Jean A. ;
Pagel, Mark D. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :399-408
[10]   A MODEL FOR MAGNETIZATION-TRANSFER IN TISSUES [J].
MORRISON, C ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :475-482