Design and analysis of cementless hip-joint system using functionally graded material

被引:2
|
作者
Asiri, Saeed [1 ]
机构
[1] Engn Coll King Abdulaziz Univ, Mech Engn Dept, Jeddah, Saudi Arabia
关键词
functionally graded material; cementless hip-joint system; natural frequency; harmonic response; fatigue analysis; finite element analysis; modal analysis; MATERIAL SELECTION; PRODUCT DESIGN; BEHAVIOR; COMPONENT; IMPLANT;
D O I
10.24425/ame.2021.139804
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Functionally Graded Materials (FGM) are extensively employed for hip plant component material due to their certain properties in a specific design to achieve the requirements of the hip-joint system. Nevertheless, if there are similar properties, it doesn't necessarily indicate that the knee plant is efficiently and effectively working. Therefore, it is important to develop an ideal design of functionally graded material femoral components that can be used for a long period. A new ideal design of femoral prosthesis can be introduced using functionally graded fiber polymer (FGFP) which will reduce the stress shielding and the corresponding stresses present over the interface. Herein, modal analysis of the complete hip plant part is carried out, which is the main factor and to date, very few research studies have been found on it. Moreover, this enhances the life of hip replacement, and the modal, harmonic, and fatigue analysis determines the pre-loading failure phenomena due to the vibrational response of the hip. This study deals with the cementless hip plant applying the finite element analysis (FEA) model in which geometry is studied, and the femoral bone model is based in a 3D scan.
引用
收藏
页码:129 / 146
页数:18
相关论文
共 50 条
  • [1] Improved Stress Shielding on a Cementless Tibia Tray using Functionally Graded Material
    Hedia, Hassan S.
    Fouda, Noha
    MATERIALS TESTING, 2013, 55 (11-12) : 845 - 851
  • [2] Functionally graded materials for knee and hip arthroplasty; an update on design, optimization, and manufacturing
    Najibi, Amir
    Mokhtari, Tahmineh
    COMPOSITE STRUCTURES, 2023, 322
  • [3] A Method of Material Optimization of Cementless Stem Through Functionally Graded Material
    H.S. Hedia
    M.A.N. Shabara
    T.T. El-Midany
    N. Fouda
    International Journal of Mechanics and Materials in Design, 2004, 1 (4) : 329 - 346
  • [4] Improving the performance of cementless knee prosthesis coating through functionally graded material
    Asiri, Saeed A.
    Hedia, Hassan S.
    Fouda, Noha
    MATERIALS TESTING, 2016, 58 (11-12) : 939 - 945
  • [5] Material optimization of a cemented tibia tray using functionally graded material
    Hedia, Hassan S.
    Aldousari, Saad M.
    Fouda, Noha
    MATERIALS TESTING, 2016, 58 (03) : 260 - 268
  • [6] Development of cementless metal-backed acetabular cup prosthesis using functionally graded material
    Hedia H.S.
    El-Midany T.T.
    Shabara M.A.N.
    Fouda N.
    International Journal of Mechanics and Materials in Design, 2005, 2 (3-4) : 259 - 267
  • [7] Finite element analysis of laser ultrasonic in functionally graded material
    Zhang, Enda
    Zhang, Jinping
    Chen, Bohui
    Liu, Changsheng
    Zhan, Yu
    APPLIED ACOUSTICS, 2023, 204
  • [8] Failure Analysis of Cementless Hip Joint Prosthesis
    Dhandapani, N.
    Babu, A. Gnanavel
    Sivasankar, M.
    MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING RESEARCH ADVANCES 1.1, 2014, 845 : 403 - 407
  • [9] Design of new generation femoral prostheses using functionally graded materials: A finite element analysis
    Oshkour, A. A.
    Abu Osman, N. A.
    Yau, Y. H.
    Tarlochan, F.
    Abas, W. A. B. Wan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H1) : 3 - 17
  • [10] Experimental Analysis of Welded Rods with a Functionally Graded Material Approach
    Basmaci, Ayse Nihan
    Filiz, Seckin
    Sahin, Mumin
    APPLIED SCIENCES-BASEL, 2020, 10 (11):