Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification

被引:47
作者
Jin, X. [1 ]
Yan, H. [1 ]
Han, C. [1 ]
Zhou, Y. [1 ]
Yi, J. [1 ]
Xie, C. [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 1, Dept Radiotherapy & Chemotherapy, Wenzhou, Peoples R China
关键词
QUALITY-ASSURANCE; PER-BEAM; IMRT; VMAT; QA; TOMOTHERAPY; PHANTOM; CANCER; BOOST;
D O I
10.1259/bjr.20140577
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate comparatively the percentage gamma passing rate (% GP) of two-dimensional (2D) and three-dimensional (3D) pre-treatment volumetric modulated arc therapy (VMAT) dosimetric verification and their correlation and sensitivity with percentage dosimetric errors (% DE). Methods: % GP of 2D and 3D pre-treatment VMAT quality assurance (QA) with different acceptance criteria was obtained by ArcCHECK (R) (Sun Nuclear Corporation, Melbourne, FL) for 20 patients with nasopharyngeal cancer (NPC) and 20 patients with oesophageal cancer. % DE were calculated from planned dose-volume histogram (DVH) and patients' predicted DVH calculated by 3DVH (R) software (Sun Nuclear Corporation). Correlation and sensitivity between % GP and % DE were investigated using Pearson's correlation coefficient (r) and receiver operating characteristics (ROCs). Results: Relatively higher % DE on some DVH-basedmetrics were observed for both patients with NPC and oesophageal cancer. Except for 2%/2mm criterion, the average % GPs for all patients undergoing VMAT were acceptablewith average rates of 97.11% +/- 1.54% and 97.39% +/- 1.37% for 2D and 3D 3%/3mm criteria, respectively. The number of correlations for 3D was higher than that for 2D (21 vs 8). However, the general correlation was still poor for all the analysed metrics (9 out of 26 for 3D 3%/3mm criterion). The average area under the curve (AUC) of ROCs was 0.66 +/- 0.12 and 0.71 +/- 0.21 for 2D and 3D evaluations, respectively. Conclusions: There is a lack of correlation between % GP and % DE for both 2D and 3D pre-treatment VMAT dosimetric evaluation. DVH-based dose metrics evaluation obtained from 3DVH will provide more useful analysis. Advances in knowledge: Correlation and sensitivity of % GP with % DE for VMAT QA were studied for the first time.
引用
收藏
页数:8
相关论文
共 24 条
[1]   Statistical variability and confidence intervals for planar dose QA pass rates [J].
Bailey, Daniel W. ;
Nelms, Benjamin E. ;
Attwood, Kristopher ;
Kumaraswamy, Lalith ;
Podgorsak, Matthew B. .
MEDICAL PHYSICS, 2011, 38 (11) :6053-6064
[2]   Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study [J].
Bedford, James L. ;
Hansen, Vibeke Nordmark ;
Mcnair, Helen A. ;
Aitken, Alexandra H. ;
Brock, Juliet E. C. ;
Warrington, Alan P. ;
Brada, Michael .
ACTA ONCOLOGICA, 2008, 47 (07) :1438-1443
[3]   3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification [J].
Carrasco, Pablo ;
Jornet, Nuria ;
Latorre, Artur ;
Eudaldo, Teresa ;
Ruiz, Agusti ;
Ribas, Montserrat .
MEDICAL PHYSICS, 2012, 39 (08) :5040-5049
[4]   IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 [J].
Ezzell, Gary A. ;
Burmeister, Jay W. ;
Dogan, Nesrin ;
LoSasso, Thomas J. ;
Mechalakos, James G. ;
Mihailidis, Dimitris ;
Molineu, Andrea ;
Palta, Jatinder R. ;
Ramsey, Chester R. ;
Salter, Bill J. ;
Shi, Jie ;
Xia, Ping ;
Yue, Ning J. ;
Xiao, Ying .
MEDICAL PHYSICS, 2009, 36 (11) :5359-5373
[5]   Experimental verification of the planned dose perturbation algorithm in an anthropomorphic phantom [J].
Feygelman, V. ;
Opp, D. ;
Zhang, G. ;
Stevens, C. ;
Nelms, B. .
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
[6]  
Feygelman Vladimir, 2010, J Appl Clin Med Phys, V11, P3169
[7]   A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy [J].
Gagne, I. M. ;
Ansbacher, W. ;
Zavgorodni, S. ;
Popescu, C. ;
Beckham, W. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24) :7167-7185
[8]   Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer [J].
Jin, Xiance ;
Yi, Jinling ;
Zhou, Yongqiang ;
Yan, Huawei ;
Han, Ce ;
Xie, Congying .
MEDICAL DOSIMETRY, 2013, 38 (04) :418-423
[9]   CRT combined with a sequential VMAT boost in the treatment of upper thoracic esophageal cancer [J].
Jin, Xiance ;
Yi, Jinling ;
Zhou, Yongqiang ;
Yan, Huawei ;
Han, Ce ;
Xie, Congying .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05) :153-161
[10]   Dosimetric verification of RapidArc treatment delivery [J].
Korreman, Stine ;
Medin, Joakim ;
Kjaer-Kristoffersen, Flemming .
ACTA ONCOLOGICA, 2009, 48 (02) :185-191