Microfluidic Immunoassays

被引:120
作者
Lin, Chun-Che [1 ]
Wang, Jung-Hao [1 ]
Wu, Hui-Wen [1 ]
Lee, Gwo-Bin [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
来源
JALA | 2010年 / 15卷 / 03期
关键词
microfluidics; immunoassay; immobilization; lab-on-a-chip; MEMS; TOTAL ANALYSIS SYSTEMS; LINKED-IMMUNOSORBENT-ASSAY; BETA-LACTAM ANTIBIOTICS; COLLOIDAL CRYSTAL BEADS; ON-CHIP IMMUNOASSAY; AUTOMATED IMMUNOASSAY; MAGNETIC PARTICLES; BILAYER-MEMBRANES; ALPHA-FETOPROTEIN; VIRUS DETECTION;
D O I
10.1016/j.jala.2010.01.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunoassays have long been widely used in a variety of applications, such as for medical diagnostics, pharmaceutical analysis, environmental, food safety testing, and for basic scientific investigations because of its simplicity, sensitivity, and specificity. Microfluidic systems, also well known as a "lab-on-a-chip" or a "micro-total-analysis-system" have attracted a lot of attention in the past two decades because of advantages associated with miniaturization, integration, and automation. A promising platform for the combination of these two technologies, microfluidic immunoassays, has been extensively explored in recent years. The aim of this article is to review recent advancements in microfluidic immunoassays. A brief introduction to immunoassays and microfluidic devices will include a literature review, followed by an in-depth discussion of essential techniques in designing a microfluidic-based immunoassay from different perspectives, including device substrates, sample/reagent transportation, surface modification, immobilization, and detection schemes. Finally, future perspectives on microfluidic immunoassays will be provided. These developments with microfluidic immunoassays may provide a promising tool for automatic, sensitive, and selective measurements in practical applications. (JALA 2010; 15:253-74)
引用
收藏
页码:253 / 274
页数:22
相关论文
共 110 条
[1]   Bulk and surface modification of silicone rubber for biomedical applications [J].
Abbasi, F ;
Mirzadeh, H ;
Katbab, AA .
POLYMER INTERNATIONAL, 2002, 51 (10) :882-888
[2]   A multianalyte ELISA for immunochemical screening of sulfonamide, fluoroquinolone and β-lactam antibiotics in milk samples using class-selective bioreceptors [J].
Adrian, Javier ;
Pinacho, Daniel G. ;
Granier, Benoit ;
Diserens, Jean-Marc ;
Sanchez-Baeza, Francisco ;
Marco, M. -Pilar .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1703-1712
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]   Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeria monocytogenes in food [J].
Blazkova, Martina ;
Koets, Marjo ;
Rauch, Pavel ;
van Amerongen, Aart .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2009, 229 (06) :867-874
[5]  
Ramírez NB, 2009, BRAZ J CHEM ENG, V26, P227
[6]   Cholera toxin subunit B detection in microfluidic devices [J].
Bunyakul, Natinan ;
Edwards, Katie A. ;
Promptmas, Chamras ;
Baeumner, Antje J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :177-186
[7]   Circulating polymerase chain reaction chips utilizing multiple-membrane activation [J].
Chih-Hao Wang ;
Chen, Yi-Yu ;
Liao, Chia-Sheng ;
Hsieh, Tsung-Min ;
Luo, Ching-Hsing ;
Wu, Jiunn-Jong ;
Lee, Huei-Huang ;
Lee, Gwo-Bin .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (02) :367-375
[8]   Label-free highly sensitive detection of (small) molecules by wavelength interrogation of integrated optical chips [J].
Cottier, K ;
Wiki, M ;
Voirin, G ;
Gao, H ;
Kunz, RE .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :241-251
[9]   Antibody immobilization on to polystyrene substrate-on-chip immunoassay for horse IgG based on fluorescence [J].
Darain, Farzana ;
Gan, Kai Ling ;
Tjin, Swee Chuan .
BIOMEDICAL MICRODEVICES, 2009, 11 (03) :653-661
[10]   On-chip detection of myoglobin based on fluorescence [J].
Darain, Farzana ;
Yager, Paul ;
Gan, Kai Ling ;
Tjin, Swee Chuan .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1744-1750