Improved current regulation of three-phase grid-connected voltage-source inverters for distributed generation systems

被引:55
作者
Guo, X. Q. [1 ]
Wu, W. Y. [1 ]
机构
[1] Yanshan Univ, Key Lab Power Elect Energy Conservat & Motor Dr H, Dept Elect Engn, Qinhuangdoa, Peoples R China
基金
中国国家自然科学基金;
关键词
STEADY-STATE-ERROR; CURRENT CONTROLLER; PWM INVERTERS; FILTERS; INTEGRATORS; HARMONICS; MODEL; RISE;
D O I
10.1049/iet-rpg.2009.0044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Stationary frame linear proportional integral (PI) control has been widely used for current regulation of three-phase voltage-source inverters for a long time, but it has disadvantages of steady-state errors for ac quantities regulation. An attractive solution to eliminate these errors is P + Resonant (PR) control. However, one of its limitations is slow transient response in the startup. So far, no literature has explicitly explained the reason for its slow response phenomena. Therefore this study reveals, for the first time, a clear description of its nature by using classical control theory. To improve the current regulation performance of PR control, a novel proportional complex integral (PCI) control is proposed in this study. Unlike PR control based on the internal model principle, the proposed PCI control is derived from the concept of infinity gain to achieve zero steady-state error. A straightforward well-formulated design procedure for the PCI controller is presented based on system bandwidth criterion. In addition, practical issues such as control delay effects and digital roundoff error mitigations are discussed. Theoretical analysis, continuous-domain simulations in the MATLAB/Simulink environment and discrete-domain digital control experiments based on TMS320F2812 DSP are carried out from the viewpoint of steady-state and dynamic performance comparisons among stationary frame PI, PR and PCI control strategies. In agreement with theoretical analysis, simulation and experimental results indicate that PCI control is the best solution among three strategies to achieve fast and accurate current regulation for three-phase grid-connected voltage-source inverters.
引用
收藏
页码:101 / 115
页数:15
相关论文
共 41 条
[1]   Suppression of line voltage related distortion in current controlled grid connected inverters [J].
Abeyasekera, T ;
Johnson, CM ;
Atkinson, DJ ;
Armstrong, M .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1393-1401
[2]  
ALAOUI A, 2007, IEEE T CIRCUITS SYST, V54, P338
[3]  
[Anonymous], 15472003 IEEE
[4]   A new mathematical model and control of a three-phase AC-DC voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :116-123
[5]   Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame [J].
Bojoi, RI ;
Griva, G ;
Bostan, V ;
Guerriero, M ;
Farina, F ;
Profumo, F .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1402-1412
[6]   Voltage control with inverter-based distributed generation [J].
Bollen, MHJ ;
Sannino, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) :519-520
[7]   Comparison of current control techniques for active filter applications [J].
Buso, S ;
Malesani, L ;
Mattavelli, P .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) :722-729
[8]   Distributed reactive power generation control for voltage rise mitigation in distribution networks [J].
Carvalho, Pedro M. S. ;
Correia, Pedro F. ;
Ferreira, Luis A. F. M. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :766-772
[9]   Linear current control scheme with series resonant harmonic compensator for single-phase grid-connected photovoltaic inverters [J].
Castilla, Miguel ;
Miret, Jaume ;
Matas, Jose ;
de Vicuna, Luis Garcia ;
Guerrero, Josep M. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (07) :2724-2733
[10]   A three-phase four-wire inverter control technique for a single distributed generation unit in island mode [J].
Dai, Min ;
Marwali, Mohammad Nanda ;
Jung, Jin-Woo ;
Keyhani, Ali .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) :322-331