In this study, we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Carlo simulations, supported by experimental data, are presented and the main advantages and drawbacks for applications of potential interest are discussed. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 18 条
[1]  
Adam LE, 2001, J NUCL MED, V42, P1821
[2]   The multigap resistive plate chamber as a time-of-flight detector [J].
Akindinov, A ;
Anselmo, F ;
Basile, M ;
Zeballos, EC ;
Cifarelli, L ;
Cindolo, F ;
Choi, J ;
Cozzoni, B ;
De Caro, A ;
De Pasquale, S ;
Kim, DW ;
Kim, NY ;
Klempt, W ;
Kluge, A ;
Laurenti, G ;
Lee, SC ;
Golovine, V ;
Hatzifotiadou, D ;
Martemiyanov, A ;
Martinengo, P ;
Pesci, A ;
Platner, E ;
Roberts, J ;
Seganti, A ;
Semak, A ;
Smirnitski, A ;
Spegel, M ;
Szymanski, P ;
Valenti, G ;
Vicinanza, D ;
Williams, MCS ;
Zichichi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 456 (1-2) :16-22
[3]   An educational tool for demonstrating the TOF-PET technique [J].
Bäck, T ;
Cederkäll, J ;
Cederwall, B ;
Johnson, A ;
Kerek, A ;
Klamra, W ;
van der Marel, J ;
Molnár, J ;
Novák, D ;
Sohler, D ;
Steèn, M ;
Uhlèn, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) :200-204
[4]   The effect of camera geometry on singles flux, scatter fraction and trues and randoms sensitivity for cylindrical 3D PET - A simulation study. [J].
Badawi, RD ;
Kohlmyer, SG ;
Harrison, RL ;
Vannoy, SD ;
Lewellen, TK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :1228-1232
[6]   Development of large area and of position-sensitive timing RPCs [J].
Blanco, A ;
Marques, RF ;
Finck, C ;
Fonte, P ;
Gobbi, A ;
Mendiratta, SK ;
Monteiro, J ;
Policarpo, A ;
Rozas, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2) :170-175
[7]  
BUDINGER TF, 1983, J NUCL MED, V24, P73
[8]  
CROSETTO DB, 2000, IEEE NUCL SCI S MED
[9]  
DERENZO SE, 1993, INT CONGR SER, V1030, P25
[10]   THE HIGH-DENSITY AVALANCHE CHAMBER FOR POSITRON EMISSION TOMOGRAPHY [J].
JEAVONS, A ;
HOOD, K ;
HERLIN, G ;
PARKMAN, C ;
TOWNSEND, D ;
MAGNANINI, R ;
FREY, P ;
DONATH, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) :640-645