Accurate quantification of width and density of bone structures by computed tomography

被引:31
作者
Hangartner, Thomas N.
Short, David F.
机构
[1] Wright State Univ, BioMed Imaging Lab, Dayton, OH 45409 USA
[2] Miami Valley Hosp, Dayton, OH 45409 USA
关键词
computed tomography; quantitative computed tomography; bone; bone width; bone density;
D O I
10.1118/1.2769102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In computed tomography (CT), the representation of edges between objects of different densities is influenced by the limited spatial resolution of the scanner. This results in the misrepresentation of density of narrow objects, leading to, errors of up to 70% and more. Our interest is in the imaging and measurement of narrow bone structures, and the issues are the same for imaging with clinical CT scanners, peripheral quantitative CT scanners or micro CT scanners. Mathematical models, phantoms and tests with patient data led to the following procedures: (i) extract density profiles at one-degree increments from the CT images at right angles to the bone boundary; (ii) consider the outer and inner edge of each profile separately due to different adjacent soft tissues; (iii) measure the width of each profile based on a threshold at fixed percentage of the difference between the soft-tissue value and a first approximated bone value; (iv) correct the underlying material density of bone for each profile based on the measured width with the help of the density-versus-width curve obtained from computer simulations and phantom measurements. This latter curve is specific to a certain scanner and is not dependent on the densities of the tissues within the range seen in patients. This procedure allows the calculation of the material density of bone. Based on phantom measurements, we estimate the density error to be below 2% relative to the density of normal bone and the bone-width error about one tenth of a pixel size. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3777 / 3784
页数:8
相关论文
共 50 条
  • [31] Validation of Thoracic Quantitative Computed Tomography as a Method to Measure Bone Mineral Density
    M. Wong
    A. Papa
    T. Lang
    H. N. Hodis
    L. LaBree
    R. Detrano
    Calcified Tissue International, 2005, 76 (1) : 7 - 10
  • [32] Regional bone mineral density differences measured by quantitative computed tomography in patients undergoing anterior cervical
    Salzmann, Stephan N.
    Okano, Ichiro
    Miller, Courtney Ortiz
    Chiapparelli, Erika
    Reisener, Marie-Jacqueline
    Winter, Fabian
    Shue, Jennifer
    Carrino, John A.
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    Hughes, Alexander P.
    SPINE JOURNAL, 2020, 20 (07) : 1056 - 1064
  • [33] Assessment of the bone mineral density in the lumbar vertebrae of newborns by quantitative computed tomography
    Braillon, PM
    Lapillonne, A
    Ho, PS
    Bouvier, R
    Bochu, M
    Salle, BL
    SKELETAL RADIOLOGY, 1996, 25 (08) : 711 - 715
  • [34] Evaluation of Bone Mineral Density by Computed Tomography in Patients with Obstructive Sleep Apnea
    Hamada, Satoshi
    Ikezoe, Kohei
    Hirai, Toyohiro
    Oguma, Tsuyoshi
    Tanizawa, Kiminobu
    Inouchi, Morito
    Handa, Tomohiro
    Oga, Toru
    Mishima, Michiaki
    Chin, Kazuo
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2016, 12 (01): : 25 - 34
  • [35] Computed tomography revealed that bone density in lambs was affected by Trichostrongylus colubriformis infection
    Dias-Silva, Tairon Pannunzio
    Abdalla, Adibe L.
    Bompadre, Thiago F. V.
    Fonseca-Pinto, Ana Carolina B. C.
    Amarante, Alessandro F. T.
    Louvandini, Helder
    SMALL RUMINANT RESEARCH, 2023, 227
  • [36] Evaluation of bone mineral density after instrumented lumbar fusion with computed tomography
    Wanderman, Nathan
    Glassman, Steven D.
    Mkorombindo, Tino
    Dimar II, John R.
    Gum, Jeffrey L.
    Carreon, Leah Y.
    SPINE JOURNAL, 2022, 22 (06) : 951 - 956
  • [37] Evaluation of Bone Mineral Density in Lung Transplant Recipients by Chest Computed Tomography
    Mori, Ryobu
    Handa, Tomohiro
    Ohsumi, Akihiro
    Ikezoe, Kohei
    Tanizawa, Kiminobu
    Uozumi, Ryuji
    Tanabe, Naoya
    Oguma, Tsuyoshi
    Sakamoto, Ryo
    Hamaji, Masatsugu
    Nakajima, Daisuke
    Yutaka, Yojiro
    Tanaka, Satona
    Yamada, Yoshito
    Oshima, Yohei
    Sato, Susumu
    Fukui, Motonari
    Date, Hiroshi
    Hirai, Toyohiro
    RESPIRATION, 2024, 103 (01) : 1 - 9
  • [38] The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis
    Suttapreyasri, Srisurang
    Suapear, Pradipat
    Leepong, Narit
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2026 - 2031
  • [39] Influence of reconstruction parameters of micro -computed tomography on the analysis of bone mineral density
    Gaeta-Araujo, Hugo
    Nascimento, Eduarda Helena Leandro
    Brasil, Danieli Moura
    Madlum, Daniela Verardi
    Haiter-Neto, Francisco
    Oliveira-Santos, Christiano
    IMAGING SCIENCE IN DENTISTRY, 2020, 50 (02) : 153 - 159
  • [40] Vertebral bone density after hip rearthroplasty assessed by quantitative computed tomography
    Adolphson, P
    JOURNAL OF ARTHROPLASTY, 1996, 11 (07) : 869 - 872