Accurate quantification of width and density of bone structures by computed tomography

被引:31
作者
Hangartner, Thomas N.
Short, David F.
机构
[1] Wright State Univ, BioMed Imaging Lab, Dayton, OH 45409 USA
[2] Miami Valley Hosp, Dayton, OH 45409 USA
关键词
computed tomography; quantitative computed tomography; bone; bone width; bone density;
D O I
10.1118/1.2769102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In computed tomography (CT), the representation of edges between objects of different densities is influenced by the limited spatial resolution of the scanner. This results in the misrepresentation of density of narrow objects, leading to, errors of up to 70% and more. Our interest is in the imaging and measurement of narrow bone structures, and the issues are the same for imaging with clinical CT scanners, peripheral quantitative CT scanners or micro CT scanners. Mathematical models, phantoms and tests with patient data led to the following procedures: (i) extract density profiles at one-degree increments from the CT images at right angles to the bone boundary; (ii) consider the outer and inner edge of each profile separately due to different adjacent soft tissues; (iii) measure the width of each profile based on a threshold at fixed percentage of the difference between the soft-tissue value and a first approximated bone value; (iv) correct the underlying material density of bone for each profile based on the measured width with the help of the density-versus-width curve obtained from computer simulations and phantom measurements. This latter curve is specific to a certain scanner and is not dependent on the densities of the tissues within the range seen in patients. This procedure allows the calculation of the material density of bone. Based on phantom measurements, we estimate the density error to be below 2% relative to the density of normal bone and the bone-width error about one tenth of a pixel size. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3777 / 3784
页数:8
相关论文
共 50 条
  • [21] Bone Mineral Density Measurements of Lumbar Vertebrae by Quantitative Computed Tomography
    Riaz, Hassan
    Khan, Obaid Ullah
    Akram, Hamid
    RAWAL MEDICAL JOURNAL, 2009, 34 (01): : 4 - +
  • [22] Addressing Challenges of Opportunistic Computed Tomography Bone Mineral Density Analysis
    Bott, Kirsten N.
    Matheson, Bryn E.
    Smith, Ainsley C. J.
    Tse, Justin J.
    Boyd, Steven K.
    Manske, Sarah L.
    DIAGNOSTICS, 2023, 13 (15)
  • [23] Computed tomography assisted, chemical and biomechanical studies on bone density and breaking strength in laying hens
    Streubel, R
    Bartels, T
    Krautwald-Junghanns, ME
    ARCHIV FUR GEFLUGELKUNDE, 2005, 69 (05): : 206 - 212
  • [24] Measurement of thickness and density of thin structures by computed tomography: A simulation study
    Dougherty, G
    Newman, D
    MEDICAL PHYSICS, 1999, 26 (07) : 1341 - 1348
  • [25] Thoracic bone mineral density measured by quantitative computed tomography in patients undergoing spine surgery
    Salzmann, Stephan N.
    Okano, Ichiro
    Jones, Conor
    Basile, Eric
    Iuso, Anthony
    Zhu, Jiaqi
    Reisener, Marie -Jacqueline
    Chiapparelli, Erika
    Shue, Jennifer
    Carrino, John A.
    Girardi, Federico P.
    Cammisa, Frank P.
    Sama, Andrew A.
    Hughes, Alexander P.
    SPINE JOURNAL, 2021, 21 (11) : 1866 - 1872
  • [26] Relations between bone density from computed tomography and bone regeneration after reduction mandibuloplasty
    Gu, Tianyi
    Xia, Songxia
    Huang, Yuanliang
    Yu, Panxi
    Zhao, Minghao
    Lu, Jianjian
    Teng, Li
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2025, 126 (02)
  • [27] Correlation of Bone Density Values of Quantitative Computed Tomography and Hounsfield Units Measured in Native Computed Tomography in 902 Vertebral Bodies
    Buenger, Fabian
    Eckardt, Niklas
    Sakr, Yasser
    Senft, Christian
    Schwarz, Falko
    WORLD NEUROSURGERY, 2021, 151 : E599 - E606
  • [28] QUANTIFICATION OF IMPORTANT MEASUREMENTS OF THE PETROUS BONE IN COMPUTED-TOMOGRAPHY PRECEDING COCHLEAR IMPLANT
    MAHER, N
    BECKER, H
    LASZIG, R
    LARYNGO-RHINO-OTOLOGIE, 1995, 74 (06) : 337 - 342
  • [29] Highly Precise Peripheral Quantitative Computed Tomography for the Evaluation of Bone Density, Loss of Bone Density and StructuresConsequences for Prophylaxis and Treatment
    Maximilian A. Dambacher
    Maurus Neff
    Ruedi Kissling
    Ling Qin
    Drugs & Aging, 1998, 12 : 15 - 24
  • [30] Computed tomography of the alveolar bone
    Schuller, H
    RADIOLOGE, 1996, 36 (03): : 221 - 225