Treatment of posttraumatic sternal non-union with a locked sternum-osteosynthesis plate (TiFix)

被引:14
作者
Queitsch, Christian [2 ]
Kienast, Benjamin [1 ]
Voigt, Christine [3 ]
Gille, Justus [4 ]
Juergens, Christian [1 ,4 ]
Schulz, Arndt P. [1 ,4 ]
机构
[1] BG Trauma Hosp Hamburg, Dept Trauma & Orthopaed Surg, D-21033 Hamburg, Germany
[2] Regio Klin, Dept Trauma & Orthopaed Surg, Wedel, Germany
[3] Diakoniekrankenhaus, Dept Trauma & Orthopaed Surg, Hannover, Germany
[4] Univ Hosp Luebeck, Dept Trauma & Orthopaed Surg, Lubeck, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2011年 / 42卷 / 01期
关键词
Fracture sternum; Non-union; Locked bone plate; Angular stability; Internal fixator; CHEST-WALL FRACTURES; SURGICAL-MANAGEMENT; UNDERUSED PROCEDURE; OPERATIVE FIXATION; STERNOTOMY; SYSTEM;
D O I
10.1016/j.injury.2010.08.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Only a minority of sternal fractures require osteosynthesis. Unstable non-union of the sternum is a very disabling condition which often requires treatment. The method most often used is tension-wiring. Due to loosening of the tensile strength or wire cut-out, this method often fails. We report the results of locked plate osteosynthesis of sternal non-union and displaced fractures. Over a five-year period, 12 patients have been treated using this method in a multicentre trial. Mean age at trauma was 32.8 years, the implant used in all cases was an 8-hole titanium plate, the fixation of the screws is based on the principles of angular stable fixation. In all cases the index procedure was possible, in all cases there was bony healing at follow-up examination. Multidirectional locked plating offers a reliable method for the successful treatment of sternal nonunion and displaced fractures. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 46
页数:3
相关论文
共 22 条
[1]  
BADELLINOM, 1988, Parhambands J Card S, V3, P235
[2]   Surgical Management of the Symptomatic Unstable Sternum with Pectoralis Major Muscle Flaps [J].
Cabbabe, Edmond B. ;
Cabbabe, Samer W. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 123 (05) :1495-1498
[3]   Sternal wound reconstruction with transverse plate fixation [J].
Cicilioni, OJ ;
Stieg, FH ;
Papanicolaou, G .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 115 (05) :1297-1303
[4]  
Coons DA, 2002, ORTHOPEDICS, V25, P89
[5]   Assessment of the radial artery and hand circulation by computed tomography angiography: A pilot study [J].
Dogan, OF ;
Karcaaltincaba, M ;
Duman, U ;
Akata, D ;
Besim, A ;
Boke, E .
HEART SURGERY FORUM, 2005, 8 (01) :E28-E33
[6]   Successful surgical management of a double-chambered left ventricle in a 13-year-old girl: A report of a rare case [J].
Dogan, OF ;
Alehan, D ;
Duman, U .
HEART SURGERY FORUM, 2004, 7 (03) :E198-E200
[7]   A wire-cutting clamp designed to reduce complications during sternotomy closure [J].
Drake, Daniel H. .
ANNALS OF THORACIC SURGERY, 2006, 82 (04) :1494-1496
[8]   Nonunion of comminuted transverse sternal fracture involving manubrio-sternal joint fixed with metal plates and autogenous bone graft [J].
Ebraheim, Nabil A. ;
Shafiq, Qaiser ;
Liu, Jiayong .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (01) :227-230
[9]   Treatment of sternal nonunion with the Dall-Miles cable system [J].
Eich, BS ;
Heinz, TR .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 106 (05) :1075-1078
[10]  
Fabian TC, 2007, AM SURGEON, V73, P596