Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails

被引:9
作者
Erden, Tunay [1 ]
Kapicioglu, Mehmet [1 ]
Demirtas, Abdullah [2 ]
Bilsel, Kerem [1 ]
Akpinar, Fuat [2 ]
Kuduz, Hacer [3 ]
机构
[1] Bezmialem Vakif Univ, Dept Orthopaed & Traumatol, Med Sch, Istanbul, Turkey
[2] Istanbul Medeniyet Univ, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Istanbul Tech Univ, Fac Mech Engn, Dept Biomech, Istanbul, Turkey
关键词
Humeral; Biomechanics; Intramedullary nail; Fracture; Distal locking; Axial and torsional stiffness; SHAFT FRACTURES; FIXATION; PLATE; SHOULDER;
D O I
10.1016/j.aott.2019.08.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. Methods: InSafeLOCK humeral nail system (group 1, TST, Istanbul, Turkey) and Expert humeral nail system (group 2, DePuy Synthes, Bettlach, Switzerland) of the same size (9 x 300 mm) were examined. In total, 24 fourth-generation humerus sawbones were used in the experiment. Osteotomy was performed at the humerus shaft, and a defect was created by removing 1 cm of bone. After pre-loading 5000 cycles at a frequency of 2 Hz and a force of 50-250 N for axial loading and 5000 torsion torques between 0.5 Nm and 6.5 Nm at a 2 Hz frequency for torsional loading, the failure load values of each load were recorded. Distal interlocking was performed with an endopin in group 1, while a double cortex screw was used in group 2. Results: All samples successfully passed the cyclic loading. The initial and final stiffness values were similar between the groups after axial loading (p = 0.873 and p = 0.522, respectively). The mean axial failure load values in groups 1 and 2 were 2627 +/- 164 N and 7141 +/- 1491 N, respectively. A significant difference was found in the axial failure load values (p = 0.004). Significant differences were observed between the initial and final torsional stiffness between the two groups (p = 0.004 and p = 0.004, respectively). No significant difference was found in the failure load values after torsional loading (11791 +/- 2055 N.mm and 16997 +/- 5440 N.mm) (p = 0.055). Conclusion: These results provide a biomechanical demonstration of the adequate stability of both nails after axial and rotational loading. The reliability of the newly developed InSafeLOCK humeral nail system, which does not require fluoroscopic control and an additional incision for distal locking, supports its use in the clinic. (C) 2019 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V.
引用
收藏
页码:490 / 496
页数:7
相关论文
共 29 条
[1]  
Augat P, 1996, CLIN ORTHOP RELAT R, P194
[2]   Complications after interlocking intramedullary nailing of humeral shaft fractures [J].
Baltov, Asen ;
Mihail, Rashkov ;
Dian, Enchev .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 :S9-S15
[3]   Shoulder function after surgical treatment of displaced fractures of the humeral shaft: a randomized trial comparing antegrade intramedullary nailing with minimally invasive plate osteosynthesis [J].
Benegas, Eduardo ;
Ferreira Neto, Arnaldo Amado ;
Conforto Gracitelli, Mauro Emilio ;
Malavolta, Eduardo Angeli ;
Assuncao, Jorge Henrique ;
Prada, Flavia De Santis ;
Bolliger Neto, Raul ;
Mattar, Rames, Jr. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (06) :767-774
[4]   Biomechanical comparison of bending and torsional properties in retrograde intramedullary nailing of humeral shaft fractures [J].
Blum, J ;
Machemer, H ;
Baumgart, F ;
Schlegel, U ;
Wahl, D ;
Rommens, PM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (05) :344-350
[5]  
Blum Jochen, 2005, J Orthop Trauma, V19, P535, DOI 10.1097/01.bot.0000164336.33272.2f
[6]   Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates [J].
Chapman, JR ;
Henley, MB ;
Agel, J ;
Benca, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (03) :162-166
[7]   A BIOMECHANICAL COMPARISON OF INTRAMEDULLARY NAILING SYSTEMS FOR THE HUMERUS [J].
DALTON, JE ;
SALKELD, SL ;
SATTERWHITE, YE ;
COOK, SD .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :367-374
[8]   DYNAMIC ELECTROMYOGRAPHIC ANALYSIS OF THE THROWING SHOULDER WITH GLENOHUMERAL INSTABILITY [J].
GLOUSMAN, R ;
JOBE, F ;
TIBONE, J ;
MOYNES, D ;
ANTONELLI, D ;
PERRY, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :220-226
[9]  
GOH JCH, 1986, PROSTHET ORTHOT INT, V10, P89
[10]   Humeral Shaft Fracture Fixation Incidence Rates and Complications as Reported by American Board of Orthopaedic Surgery Part II Candidates [J].
Gottschalk, Michael B. ;
Carpenter, William ;
Hiza, Elise ;
Reisman, William ;
Roberson, James .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (17) :e71