Intervertebral measurement of lumbar segmental motion with a new measuring device

被引:4
作者
Zhang, YM [1 ]
Voor, MJ [1 ]
Wang, M [1 ]
Johnson, JR [1 ]
机构
[1] Univ Louisville, Sch Med, Dept Orthopaed Surg, Louisville, KY 40292 USA
关键词
lumbar spine; fusion; intervertebral motion; spinal instrumentation; motion segment;
D O I
10.1016/S1350-4533(97)00053-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new Intervertebral Motion Device (IMD) was developed in this study. Depending on its configuration, the TMD was used to measure motion in the sagittal, frontal, and transverse planes. Calibration results showed that the root-mean-square (RMS) error of the IMD was 0.092 mm in axial translation, 0.065 mm in shear translation, and 0.091 degrees in rotation. Using the IMD, nine intact human lumbosacral spine specimens (L3-S1) were tested under a simulated physiological load on an MTS (Model 858 Bionix, MTS System Corporation, Minneapolis, MN). The ranges of motion (ROMs) of intact and instrumented specimens were measured in terms of angular motion (main motion) and coupled translation in the sagittal plane, frontal plane, and angular motion in the transverse plane. The results demonstrated that simulated fusion with CD instrumentation at the level of L4-L5 significantly decreased the ROMs of L4-L5 for all main and coupled motions (P < 0.03). The application of CD rods had less influence on the angular ROM in L/R axial rotation compared to the angular ROMs in Flex/Ext and L/R lateral bending. (C) 1998 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 32 条
[1]   Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments [J].
Chow, DHK ;
Luk, KDK ;
Evans, JH ;
Leong, JCY .
SPINE, 1996, 21 (05) :549-555
[2]  
DVORAK J, 1991, SPINE, V16, P562
[3]   BIOMECHANICS OF POSTERIOR LUMBAR FIXATION - ANALYSIS OF TESTING METHODOLOGIES [J].
EDWARDS, WT .
SPINE, 1991, 16 (10) :1224-1232
[4]   Kinematic evaluation of lumbar fusion techniques [J].
Esses, SI ;
Doherty, BJ ;
Crawford, MJ ;
Dreyzin, V .
SPINE, 1996, 21 (06) :676-684
[5]   SYMPOSIUM - THE ROLE OF SPINE FUSION [J].
FARFAN, HF .
SPINE, 1981, 6 (03) :278-278
[6]   MOTION OF LUMBOSACRAL SPINE AFTER LAMINECTOMY AND SPINE FUSION - CORRELATION OF MOTION WITH RESULT [J].
FRONING, EC ;
FROHMAN, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1968, A 50 (05) :897-&
[7]   L-4-5 ISTHMIC SPONDYLOLISTHESIS - A BIOMECHANICAL ANALYSIS COMPARING STABILITY IN L4-5 AND L5-S1 ISTHMIC SPONDYLOLISTHESIS [J].
GROBLER, LJ ;
NOVOTNY, JE ;
WILDER, DG ;
FRYMOYER, JW ;
POPE, MH .
SPINE, 1994, 19 (02) :222-227
[8]   CLINICAL AND RADIOLOGICAL EVALUATION OF LUMBOSACRAL MOTION BELOW FUSION LEVELS IN IDIOPATHIC SCOLIOSIS [J].
HAYES, MA ;
TOMPKINS, SF ;
HERNDON, WA ;
GRUEL, CR ;
KOPTA, JA ;
HOWARD, TC .
SPINE, 1988, 13 (10) :1161-1167
[9]   LARGE COMPRESSIVE PRELOADS DECREASE LUMBAR MOTION SEGMENT FLEXIBILITY [J].
JANEVIC, J ;
ASHTONMILLER, JA ;
SCHULTZ, AB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :228-236
[10]   EXPERIMENTAL INSTABILITY IN THE LUMBAR SPINE [J].
KAIGLE, AM ;
HOLM, SH ;
HANSSON, TH .
SPINE, 1995, 20 (04) :421-430