Stent Implantation Influence Wall Shear Stress Evolution

被引:0
|
作者
Bernad, S. I. [1 ]
Totorean, A. F. [2 ]
Bosioc, A. I. [2 ]
Petre, I. [3 ]
Bernad, E. S. [3 ]
机构
[1] Romanian Acad, Timisoara Branch, Mihai Viteazul Str 24, RO-300223 Timisoara, Romania
[2] Univ Politehn Timisoara, Dept Hydraul Machinery, Mihai Viteazul Str 1, RO-300222 Timisoara, Romania
[3] Univ Med & Pharm Victor Babes Timisoara, P Ta Eftimie Murgu 2, Timisoara, Romania
来源
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2015 (ICNAAM-2015) | 2016年 / 1738卷
关键词
coronary stent; secondary flow; wall shear stress; recirculation;
D O I
10.1063/1.4951783
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Wall shear stress in accelerating pipe flows
    He, S
    Jackson, JD
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 442 - 448
  • [42] In Vitro Comparison of the Effect of Stent Configuration on Wall Shear Stress Using Time-resolved Particle Image Velocimetry
    John Charonko
    Satyaprakash Karri
    Jaime Schmieg
    Santosh Prabhu
    Pavlos Vlachos
    Annals of Biomedical Engineering, 2010, 38 : 889 - 902
  • [43] In Vitro Comparison of the Effect of Stent Configuration on Wall Shear Stress Using Time-resolved Particle Image Velocimetry
    Charonko, John
    Karri, Satyaprakash
    Schmieg, Jaime
    Prabhu, Santosh
    Vlachos, Pavlos
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 889 - 902
  • [44] INFLUENCE OF VESSEL ROUGHNESS ON WALL SHEAR STRESS IN IMAGE-BASED BLOOD FLOW MODELING
    Xiong, Guanglei
    Taylor, Charles A.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 33 - 36
  • [45] Influence of fluid distribution on the wall shear stress in a plane ultrafiltration module using an electrochemical method
    Gaucher, C
    Legentilhomme, P
    Jaouen, P
    Comiti, J
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2002, 80 (A1): : 111 - 120
  • [46] Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula
    Krishnamoorthy, Mahesh K.
    Banerjee, Rupak K.
    Wang, Yang
    Zhang, Jianhua
    Roy, Abhijit Sinha
    Khoury, Saeb F.
    Arend, Lois J.
    Rudich, Steve
    Roy-Chaudhury, Prabir
    KIDNEY INTERNATIONAL, 2008, 74 (11) : 1410 - 1419
  • [47] Influence of Vasoactive Drugs on Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation: An In Vitro Study
    C. S. Lee
    John M. Tarbell
    Annals of Biomedical Engineering, 1998, 26 : 200 - 212
  • [48] Influence of vasoactive drugs on wall shear stress distribution in the abdominal aortic bifurcation: An in vitro study
    Lee, CS
    Tarbell, JM
    ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (02) : 200 - 212
  • [49] Wall shear stress measurements and parametric analysis of impinging wall jets
    Loureiro, J. B. R.
    Silva Freire, A. P.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (23-24) : 6400 - 6409
  • [50] Optimization of multiplane μPIV for wall shear stress and wall topography characterization
    Massimiliano Rossi
    Ralph Lindken
    Jerry Westerweel
    Experiments in Fluids, 2010, 48 : 211 - 223