Ethyl Glucuronide, Ethyl Sulfate, and Ethanol in Urine after Sustained Exposure to an Ethanol-Based Hand Sanitizer

被引:50
|
作者
Reisfield, Gary M. [1 ]
Goldberger, Bruce A. [1 ,2 ]
Crews, Bridgit O. [3 ]
Pesce, Amadeo J. [3 ]
Wilson, George R. [4 ]
Teitelbaum, Scott A. [1 ]
Bertholf, Roger L. [5 ]
机构
[1] Univ Florida, Coll Med, Dept Psychiat, Gainesville, FL 32606 USA
[2] Univ Florida, Coll Med, Dept Pathol Immunol & Lab Med, Gainesville, FL 32606 USA
[3] Millennium Res Inst, San Diego, CA USA
[4] Univ Florida, Hlth Sci Ctr, Dept Community Hlth & Family Med, Jacksonville, FL 32209 USA
[5] Univ Florida, Hlth Sci Ctr, Dept Pathol, Jacksonville, FL 32209 USA
关键词
ETHYLGLUCURONIDE; BIOMARKER; HUMANS;
D O I
10.1093/anatox/35.2.85
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To assess the degree of ethanol absorption and subsequent formation of urinary ethyl glucuronide (EtG) and ethyl sulfate (EtS) following sustained application of hand sanitizer, 11 volunteers cleansed their hands with Purell™ hand sanitizer (62% ethanol) every 5 min for 10 h on three consecutive days. Urine specimens were obtained at the beginning and end of each day of the study, and on the morning of the fourth day. Urinary creatinine, ethanol, EtG, and EtS concentrations were measured. EtG was undetectable in all pre-study urine specimens, but two pre-study specimens had detectable EtS (73 and 37 ng/mL). None of the pre-study specimens had detectable ethanol. The maximum EtG and EtS concentrations over the course of the study were 2001 and 84 ng/mL, respectively, and nearly all EtG- and EtS-positive urine specimens were collected at the conclusion of the individual study days. Only two specimens had detectable EtG at the beginning of any study day (96 and 139 ng/mL), and only one specimen had detectable EtS at the beginning of a study day (64 ng/mL), in addition to the two with detectable EtS prior to the study. Creatinine-adjusted maximum EtG and EtS concentrations were 1998 and 94 μg/g creatinine, respectively. In patients being monitored for ethanol use by urinary EtG concentrations, currently accepted EtG cutoffs do not distinguish between ethanol consumption and incidental exposures, particularly when urine specimens are obtained shortly after sustained use of ethanol-containing hand sanitizer. Our data suggest that EtS may be an important complementary biomarker in distinguishing ethanol consumption from dermal exposure. © 2010 Publishing Technology.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [31] Development and Validation of Seven Phosphatidylethanol Homologues in Dried Blood Spots Including Preliminary Results after Excessive Use of an Ethanol-Based Hand Sanitizer
    Herzog, Josefine
    Skopp, Gisela
    Musshoff, Frank
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2023, 47 (03) : 245 - 252
  • [32] The influence of ethanol containing cosmetics on ethyl glucuronide concentration in hair
    Ferreira, Liliane Martins
    Binz, Tina
    Yegles, Michel
    FORENSIC SCIENCE INTERNATIONAL, 2012, 218 (1-3) : 123 - 125
  • [33] Validation of a novel method to identify in utero ethanol exposure: simultaneous meconium extraction of fatty acid ethyl esters, ethyl glucuronide, and ethyl sulfate followed by LC-MS/MS quantification
    Himes, Sarah K.
    Concheiro, Marta
    Scheidweiler, Karl B.
    Huestis, Marilyn A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (07) : 1945 - 1955
  • [34] Ethyl glucuronide and ethyl sulfate in autopsy samples 27 years after death
    Lucia Politi
    Luca Morini
    Francesco Mari
    Angelo Groppi
    Elisabetta Bertol
    International Journal of Legal Medicine, 2008, 122 : 507 - 509
  • [35] Validation of a novel method to identify in utero ethanol exposure: simultaneous meconium extraction of fatty acid ethyl esters, ethyl glucuronide, and ethyl sulfate followed by LC-MS/MS quantification
    Sarah K. Himes
    Marta Concheiro
    Karl B. Scheidweiler
    Marilyn A. Huestis
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1945 - 1955
  • [36] Ethyl glucuronide - the direct ethanol metabolite on the threshold from science to routine use
    Wurst, FM
    Skipper, GE
    Weinmann, W
    ADDICTION, 2003, 98 : 51 - 61
  • [37] Ethyl glucuronide and ethanol concentrations in femoral blood, urine and vitreous humor from 117 autopsy cases
    Neumann, Jasna
    Keller, Thomas
    Monticelli, Fabio
    Beck, Olof
    Boettcher, Michael
    FORENSIC SCIENCE INTERNATIONAL, 2021, 318
  • [38] A novel and an effective analytical approach for the LC-MS determination of ethyl glucuronide and ethyl sulfate in urine
    Donata Favretto
    Alessandro Nalesso
    Giampietro Frison
    Guido Viel
    Pietro Traldi
    Santo Davide Ferrara
    International Journal of Legal Medicine, 2010, 124 : 161 - 164
  • [39] Phosphatidylethanol, ethyl glucuronide and ethanol in blood as complementary biomarkers for alcohol consumption
    Neumann, Jasna
    Beck, Olof
    Boettcher, Michael
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2021, 22 : 3 - 7
  • [40] False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer
    Arndt, Torsten
    Gruener, Joachim
    Schroefel, Stefanie
    Stemmerich, Karsten
    FORENSIC SCIENCE INTERNATIONAL, 2012, 223 (1-3) : 359 - 363