Temperature monitoring in radiofrequency catheter ablation of atrial flutter using the linear ablation technique

被引:12
|
作者
Wen, ZC
Chen, SA
Tai, CT
Chiang, CE
Lee, SH
Chen, YJ
Yu, WC
Huang, JL
Chang, MS
机构
[1] VET GEN HOSP,DIV CARDIOL,TAIPEI,TAIWAN
[2] NATL YANG MING UNIV,SCH MED,DEPT MED,DIV CARDIOL,TAIPEI 112,TAIWAN
[3] SHIN KONG MEM HOSP,DEPT MED,TAIPEI,TAIWAN
[4] VET GEN HOSP,DEPT MED,DIV CARDIOL,TAICHUNG,TAIWAN
关键词
atrial flutter; temperature control; radiofrequency; catheter ablation;
D O I
10.1111/j.1540-8167.1996.tb00480.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Information about temperature and impedance monitoring during radiofrequency catheter linear ablation of atrial flutter has not been reported. We proposed that a radiofrequency catheter ablation system using a closed-loop temperature control model could decrease the incidence of coagulum formation and shorten the radiation exposure and procedure times compared with those found in a power control model. Methods and Results: Forty patients (8 women and 32 men; mean age 64 +/- 7 years) with atrial flutter were referred for radiofrequency ablation. The patients were randomized into two groups: group I patients underwent radiofrequency catheter linear ablation of atrial flutter using a power control of energy output model; and group II patients underwent the closed-loop temperature control model with a target electrode temperature of 70 degrees C. As compared with group II, group I patients had a higher incidence of coagulum formation (12% vs 2%, P < 0.05), temperature shutdown (11% vs 0%, P < 0.01), and impedance shutdown (16% vs 3%, P < 0.01), more radiofrequency applications (7 +/- 3 vs 4 +/- 2, P < 0.01), and longer procedure time (100 +/- 25 vs 75 +/- 23 minutes, P < 0.05) and radiation exposure time (31 +/- 10 vs 20 +/- 7 minutes, P < 0.05) required for successful ablation. Larger deviations of temperature (9.0 degrees +/- 2.4 degrees C vs 5.0 degrees +/- 1.2 degrees C, P < 0.0001) and impedance (9.2 +/- 2.6 Ohm vs 5.3 +/- 1.6 Ohm, P < 0.0001) were also found in group I patients compared with those in group II. Conclusions: This study demonstrated that a closed-loop temperature control model could facilitate the effects of radiofrequency catheter ablation of the atrial flutter circuit by decreasing coagulum formation, temperature and impedance shutdown, and procedure and radiation exposure times.
引用
收藏
页码:1050 / 1057
页数:8
相关论文
共 50 条
  • [41] THE BIOPHYSICS OF RADIOFREQUENCY CATHETER ABLATION IN THE HEART - THE IMPORTANCE OF TEMPERATURE MONITORING
    HAINES, DE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03): : 586 - 591
  • [42] Successful radiofrequency catheter ablation of common atrial flutter at the bottom of a coronary sinus diverticulum
    Miyako Igarashi
    Hiroshi Tada
    Yukio Sekiguchi
    Kazutaka Aonuma
    Heart and Vessels, 2012, 27 : 643 - 647
  • [43] Apparent bidirectional conduction block following radiofrequency catheter ablation of typical atrial flutter
    Quintos, RF
    Barakat, T
    Mecca, A
    Olshansky, B
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (01) : 109 - 118
  • [44] Radiofrequency catheter ablation of focal atrial fibrillation
    Peinado, RP
    Llorens, JLM
    Guindal, JAG
    Daza, JAS
    REVISTA ESPANOLA DE CARDIOLOGIA, 1998, 51 (06): : 494 - 497
  • [45] Typical atrial flutter : History, mechanisms and radiofrequency "ablation"
    Saoudi, Nadir
    Ricard, Philippe
    Rinaldi, Jean-Paul
    Anselme, Frederic
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2006, 190 (01): : 139 - 151
  • [46] Safety and efficacy of cryothermal and radiofrequency catheter ablation in treatment of typical atrial flutter
    Wang Fang
    Huang Cong-xin
    Chen Gang
    Zhang Feng
    Meng Wei-dong
    Sun Bao-gui
    CHINESE MEDICAL JOURNAL, 2007, 120 (11) : 1007 - 1009
  • [47] Rapid Linear Ventricular Ablation Using a Novel Irrigated Multipolar Radiofrequency Ablation Catheter
    Nazer, Babak
    Walters, Tomos E.
    Duggirala, Srikant
    Gerstenfeld, Edward P.
    CIRCULATION, 2016, 134
  • [48] Safety and efficacy of cryothermal and radiofrequency catheter ablation in treatment of typical atrial flutter
    WANG Fang HUANG Cong-xin CHEN Gang ZHANG Feng MENG Wei-dong SUN Bao-gui Wuhan Renmin Hospital Wuhan University
    中华医学杂志(英文版), 2007, (11) : 1007 - 1009
  • [49] Electrophysiologic study and radiofrequency catheter ablation of isthmus-independent atrial flutter
    Lai, LP
    Lin, JL
    Tseng, CD
    Huang, SKS
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (05) : 728 - 735
  • [50] Atrial flutter and myotonic dystrophy in a male adolescent treated with radiofrequency catheter ablation
    Halawa, Ahmad
    Iskandar, Said B.
    Brahmbhatt, Vipul
    Fahrig, Stephen A.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2007, 8 (02) : 118 - 122