Temperature monitoring in radiofrequency catheter ablation of atrial flutter using the linear ablation technique

被引:12
|
作者
Wen, ZC
Chen, SA
Tai, CT
Chiang, CE
Lee, SH
Chen, YJ
Yu, WC
Huang, JL
Chang, MS
机构
[1] VET GEN HOSP,DIV CARDIOL,TAIPEI,TAIWAN
[2] NATL YANG MING UNIV,SCH MED,DEPT MED,DIV CARDIOL,TAIPEI 112,TAIWAN
[3] SHIN KONG MEM HOSP,DEPT MED,TAIPEI,TAIWAN
[4] VET GEN HOSP,DEPT MED,DIV CARDIOL,TAICHUNG,TAIWAN
关键词
atrial flutter; temperature control; radiofrequency; catheter ablation;
D O I
10.1111/j.1540-8167.1996.tb00480.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Information about temperature and impedance monitoring during radiofrequency catheter linear ablation of atrial flutter has not been reported. We proposed that a radiofrequency catheter ablation system using a closed-loop temperature control model could decrease the incidence of coagulum formation and shorten the radiation exposure and procedure times compared with those found in a power control model. Methods and Results: Forty patients (8 women and 32 men; mean age 64 +/- 7 years) with atrial flutter were referred for radiofrequency ablation. The patients were randomized into two groups: group I patients underwent radiofrequency catheter linear ablation of atrial flutter using a power control of energy output model; and group II patients underwent the closed-loop temperature control model with a target electrode temperature of 70 degrees C. As compared with group II, group I patients had a higher incidence of coagulum formation (12% vs 2%, P < 0.05), temperature shutdown (11% vs 0%, P < 0.01), and impedance shutdown (16% vs 3%, P < 0.01), more radiofrequency applications (7 +/- 3 vs 4 +/- 2, P < 0.01), and longer procedure time (100 +/- 25 vs 75 +/- 23 minutes, P < 0.05) and radiation exposure time (31 +/- 10 vs 20 +/- 7 minutes, P < 0.05) required for successful ablation. Larger deviations of temperature (9.0 degrees +/- 2.4 degrees C vs 5.0 degrees +/- 1.2 degrees C, P < 0.0001) and impedance (9.2 +/- 2.6 Ohm vs 5.3 +/- 1.6 Ohm, P < 0.0001) were also found in group I patients compared with those in group II. Conclusions: This study demonstrated that a closed-loop temperature control model could facilitate the effects of radiofrequency catheter ablation of the atrial flutter circuit by decreasing coagulum formation, temperature and impedance shutdown, and procedure and radiation exposure times.
引用
收藏
页码:1050 / 1057
页数:8
相关论文
共 50 条
  • [21] Acute Myocardial Infarction after Radiofrequency Catheter Ablation of Typical Atrial Flutter
    Yune, Sehyo
    Lee, Woo Joo
    Hwang, Ji-won
    Kim, Eun
    Ha, Jung Min
    Kim, June Soo
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (02) : 292 - 295
  • [22] Transvenous radiofrequency catheter ablation for atrial flutter and atrial fibrillation - The end of the beginning?
    Wyse, D. George
    CIRCULATION, 2006, 114 (16) : 1670 - 1672
  • [23] Radiofrequency catheter ablation of atrial tachycardias
    Llorens, JLM
    Maiz, AA
    PerezVillacastin, J
    Garrote, JA
    Peinado, RP
    Moreno, OM
    Monedero, CM
    Dominguez, JLD
    REVISTA ESPANOLA DE CARDIOLOGIA, 1997, 50 (04): : 239 - 247
  • [24] Bipolar Radiofrequency Ablation of Typical Atrial Flutter
    Futyma, Piotr
    Futyma, Marian
    Maciolek, Marcin
    Kulakowski, Piotr
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (07) : 874 - 875
  • [25] TYPICAL ATRIAL FLUTTER: RADIOFREQUENCY CATHETER ABLATION OF CAVOTRICUSPID ISTHMUS WITH COOLED-TIP CATHETER
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (01): : 21 - 26
  • [26] Catheter inversion: A technique to complete isthmus ablation and cure atrial flutter
    Sporton, SC
    Davies, DW
    Earley, MJ
    Markides, V
    Nathan, AW
    Schilling, RJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 775 - 778
  • [27] Radiofrequency catheter ablation for atrial flutter following orthotopic heart transplantation
    Pitt, MPI
    Bosner, RS
    Griffith, MJ
    HEART, 1998, 79 (04) : 412 - 413
  • [28] Electrophysiologic characteristics and radiofrequency catheter ablation in patients with clockwise atrial flutter
    Tai, CT
    Chen, SA
    Chiang, CE
    Lee, SH
    Ueng, KC
    Wen, ZC
    Chen, YJ
    Yu, WC
    Huang, JL
    Chiou, CW
    Chang, MS
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (01) : 24 - 34
  • [29] RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF COMMON ATRIAL-FLUTTER IN HUMANS
    YANG, XC
    WATANABE, I
    KOJIMA, T
    TAKAHASHI, Y
    KANDA, A
    KUNIMOTO, S
    KONDO, K
    KASAMAKI, Y
    SAITO, S
    OZAWA, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1995, 59 (02): : 68 - 79
  • [30] Radiofrequency catheter ablation of common atrial flutter: Role of the Eustachian valve
    Halimi, F
    Hidden-Lucet, F
    Tonet, J
    Fontaine, G
    Frank, R
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (02) : 169 - 172