High-speed RNA microextraction technology using magnetic oligo-dT beads and lateral magnetophoresis

被引:39
作者
Lee, Hwanyong [1 ]
Jung, Jinhee [1 ]
Han, Song-I [1 ]
Han, Ki-Ho [1 ]
机构
[1] Inje Univ, Sch Nano Engn, Gimhae 621749, Gyongnam, South Korea
关键词
MESSENGER-RNA; SOLID-PHASE; PURIFICATION; BLOOD; SYSTEM; SEPARATION; DIAGNOSIS; SILICA; CELLS; DNA;
D O I
10.1039/c005145d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a high-speed RNA microextractor for the direct isolation of RNA from peripheral blood lysate using magnetic oligo-dT beads. The extraction is achieved through lateral magnetophoresis, generated by a ferromagnetic wire array inlaid on a glass substrate. This RNA microextractor separated more than 80% of magnetic beads with a flow rate up to 20 ml h(-1), and the overall extraction procedure was completed within 1 min. The absorbance ratio of RNA to protein (A(260)/A(280)) was > 1.7, indicating that the extraction technology yielded nearly pure RNA. The feasibility of this technique was evaluated further for its applicability to reverse transcription polymerase chain reaction (RT-PCR) procedures by performing cDNA synthesis and PCR. The analysis verified that the RNA microextractor is a practical method for easy, rapid, and high-precision RT-PCR using minimal reagent volumes without requiring highly trained personnel. In addition, it can be readily incorporated into genetic analysis procedures for realizing automated on-chip genetic platforms in a micro format.
引用
收藏
页码:2764 / 2770
页数:7
相关论文
共 31 条
[1]   Multitarget magnetic activated cell sorter [J].
Adams, Jonathan D. ;
Kim, Unyoung ;
Soh, H. Tom .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (47) :18165-18170
[2]   Electrokinetically controlled microfluidic analysis systems [J].
Bousse, L ;
Cohen, C ;
Nikiforov, T ;
Chow, A ;
Kopf-Sill, AR ;
Dubrow, R ;
Parce, JW .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 2000, 29 :155-181
[3]   Microchip-based purification of DNA from biological samples [J].
Breadmore, MC ;
Wolfe, KA ;
Arcibal, IG ;
Leung, WK ;
Dickson, D ;
Giordano, BC ;
Power, ME ;
Ferrance, JP ;
Feldman, SH ;
Norris, PM ;
Landers, JP .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1880-1886
[4]   DETECTION OF EPITHELIAL CANCER-CELLS IN PERIPHERAL-BLOOD BY REVERSE-TRANSCRIPTASE POLYMERASE CHAIN-REACTION [J].
BURCHILL, SA ;
BRADBURY, MF ;
PITTMAN, K ;
SOUTHGATE, J ;
SMITH, B ;
SELBY, P .
BRITISH JOURNAL OF CANCER, 1995, 71 (02) :278-281
[5]   Nucleic acid purification using microfabricated silicon structures [J].
Cady, NC ;
Stelick, S ;
Batt, CA .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (01) :59-66
[6]   A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability [J].
Easley, Christopher J. ;
Karlinsey, James M. ;
Bienvenue, Joan M. ;
Legendre, Lindsay A. ;
Roper, Michael G. ;
Feldman, Sanford H. ;
Hughes, Molly A. ;
Hewlett, Erik L. ;
Merkel, Tod J. ;
Ferrance, Jerome P. ;
Landers, James P. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (51) :19272-19277
[7]   Characterisation of Dynabeads® by magnetization measurements and Mossbauer spectroscopy [J].
Fonnum, G ;
Johansson, C ;
Molteberg, A ;
Morup, S ;
Aksnes, E .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :41-47
[8]   Microchip-Based Solid-Phase Purification of RNA from Biological Samples [J].
Hagan, Kristin A. ;
Bienvenue, Joan M. ;
Moskaluk, Christopher A. ;
Landers, James P. .
ANALYTICAL CHEMISTRY, 2008, 80 (22) :8453-8460
[9]   Chitosan-Coated Silica as a Solid Phase for RNA Purification in a Microfluidic Device [J].
Hagan, Kristin A. ;
Meier, Whitney L. ;
Ferrance, Jerome P. ;
Landers, James P. .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5249-5256
[10]  
Hämäläinen MM, 1999, CLIN CHEM, V45, P465