Clinical outcomes and cost-utility after sirolimus-eluting versus bare metal stent implantation

被引:4
|
作者
Zhao Fu-hai [1 ]
Lue Shu-zheng [1 ]
Li Hui [2 ]
Ning Shang-qiu [1 ]
Yuan Fei [1 ]
Song Xian-tao [1 ]
Jin Ze-ning [1 ]
Zhou Yuan [1 ]
Chen Xin [1 ]
Liu Hong [1 ]
Tian Rui [1 ]
Meng Kang [1 ]
Li Hong [1 ]
Han Feng [2 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China
[2] China Res Assoc Med Insurance Fund, Beijing 100029, Peoples R China
关键词
sirolimus-eluting stent; bare metal stent; clinical outcomes; cost-utility; health-related quality of life; QUALITY-OF-LIFE; BYPASS GRAFT-SURGERY; TRIAL; THROMBOSIS; ANGIOPLASTY; RESTENOSIS; LESIONS; EVENTS; ANGINA; RISK;
D O I
10.3760/cma.j.issn.0366-6999.2010.20.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Randomized studies have shown beneficial effects of drug-eluting stent (DES) in reducing the risk of repeated revascularization. Other studies have shown higher proportion of death, myocardial infarction (MI) and increased cost concerning DES. However the long term safety and effectiveness of DES have been questioned recently. Methods To compare long term clinical outcomes, health-related quality of life (HRQOL) and cost-utility after sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation in angina patients in China, 1241 patients undergoing percutaneous coronary revascularization (PCI) with either SES (n=632) or BMS (n=609) were enrolled continuously in this prospective, nonrandomized, multi-center registry study. Results Totally 1570 stents were implanted for 1334 lesions. Follow-up was completed in 1205 (97.1%) patients at 12 months. Rates of MI, all causes of death were similar between the two groups. Significant differences were found at rate of cardiovascular re-hospitalization (136 (22.4%) in BMS group vs. 68 (10.8%) in SES group, P=0.001) and recurrent angina (149 (24.5%) vs. 71 (11.3%), P=0.001). Dramatic difference was observed when compared the baseline and 9-month HRQOL scores intra-group (P < 0.001). However no significant difference was found inter-group either in baseline or follow-up HRQOL. Compared with SES, the total cost in BMS was significantly lower on discharge (62 546.0 vs. 78 245.0 Yuan, P=0.001). And follow-up expenditure was remarkably higher in the BMS group than that in the SES group (13 412.0 vs. 8 812.0 Yuan, P=0.0001). Conclusions There were no significant differences on death, in-stent thrombosis, MI irrespective of stent type. SES was superior to BMS on improvement of life quality. SES was with higher cost-utility compared to BMS. Chin Med J 2010;123(20):2797-2802
引用
收藏
页码:2797 / 2802
页数:6
相关论文
共 50 条
  • [1] Repeated Sirolimus-Eluting Stent Implantation to Treat Sirolimus-Eluting Stent and Bare-Metal Stent Restenosis
    Nishihira, Kensaku
    Shibata, Yoshisato
    Ishikawa, Tetsunori
    Nomura, Katsumasa
    Nakama, Tatsuya
    Mine, Daigo
    Inoue, Yohei
    Ashikaga, Keiichi
    Kuriyama, Nehiro
    Matsuyama, Akihiko
    Imamura, Takuroh
    Asada, Yujiro
    Kitamura, Kazuo
    CIRCULATION JOURNAL, 2010, 74 (11) : 2329 - 2333
  • [2] Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions
    Jorgensen, Erik
    Kelbaek, Henning
    Klovgaard, Lene
    Thuesen, Leif
    Krusell, Lars R.
    Botker, Hans E.
    Saunamaki, Kari
    Lassen, Jens F.
    Helqvist, Steffen
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (01) : 162 - 163
  • [3] Late Progression After Sirolimus-Eluting Stent Implantation for de Novo Lesions - Comparison With Bare Metal Stent Implantation
    Shiode, Nobuo
    Shirota, Kinya
    Tsunoda, Fumiyo
    Kato, Yasuko
    Fujiwara, Mai
    Mimura, Asao
    CIRCULATION JOURNAL, 2010, 74 (06) : 1104 - 1110
  • [4] Long-term Clinical Outcomes After Sirolimus-Eluting Stent Implantation in Dialysis Patients
    Ichimoto, Eiji
    Kobayashi, Yoshio
    Iijima, Yoshihiro
    Kuroda, Nakabumi
    Kohno, Yukinori
    Komuro, Issei
    INTERNATIONAL HEART JOURNAL, 2010, 51 (02) : 92 - 97
  • [5] Long-term clinical outcomes after sirolimus-eluting Stent implantation for treatment of restenosis within bare-metal versus drug-eluting stents
    Lee, Cheol Whan
    Kim, Sang-Hyun
    Suh, Jon
    Park, Duk-Woo
    Lee, Seung-Hwan
    Kim, Young-Hak
    Hong, Myeong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (05) : 594 - 598
  • [6] Fifteen-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation
    Nishiura, Naoki
    Kubo, Shunsuke
    Fujii, Chihiro
    Shima, Yuki
    Ikuta, Akihiro
    Osakada, Kohei
    Tada, Takeshi
    Fuku, Yasushi
    Tanaka, Hiroyuki
    Kadota, Kazushige
    CIRCULATION JOURNAL, 2024, 88 (06) : 938 - 943
  • [7] 5-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation Insights From a Patient-Level Pooled Analysis of 4 Randomized Trials Comparing Sirolimus-Eluting Stents With Bare-Metal Stents
    Caixeta, Adriano
    Leon, Martin B.
    Lansky, Alexandra J.
    Nikolsky, Eugenia
    Aoki, Jiro
    Moses, Jeffrey W.
    Schofer, Joachim
    Morice, Marie-Claude
    Schampaert, Erick
    Kirtane, Ajay J.
    Popma, Jeffrey J.
    Parise, Helen
    Fahy, Martin
    Mehran, Roxana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (10) : 894 - 902
  • [8] Clinical characteristics of stent fracture after sirolimus-eluting stent implantation
    Yang, Tae-Hyun
    Kim, Doo-Il
    Park, Seong-Gill
    Seo, Jeong-Sook
    Cho, Hwan-Jin
    Seol, Sang-Hoon
    Kim, Seong-Man
    Kim, Dae-Kyeong
    Kim, Dong-Soo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 131 (02) : 212 - 216
  • [9] Late Restenosis Following Sirolimus-Eluting Stent Implantation
    Kuriyama, Nehiro
    Kobayashi, Yoshio
    Nakama, Tatsuya
    Mine, Daigo
    Nishihira, Kensaku
    Shimomura, Mitsuhiro
    Nomura, Katsumasa
    Ashikaga, Keiichi
    Matsuyama, Akihiko
    Shibata, Yoshisato
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 123 - 128
  • [10] Retrospective Comparison of Clinical and Angiographic Outcomes After Sirolimus-Eluting and Bare-Metal Stent Implantation in 312 Consecutive, Nonrandomized Severely Calcified Lesions Using a Rotablator
    Kubota, Takeyuki
    Ishikawa, Tetsuya
    Nakano, Yosuke
    Endoh, Akira
    Suzuki, Teruhiko
    Sakamoto, Hiroshi
    Hasuda, Toshio
    Imai, Kamon
    Yoshimura, Michihiro
    Mutoh, Makoto
    INTERNATIONAL HEART JOURNAL, 2011, 52 (02) : 65 - 71