Experimental study on solving the blocking for the direct contact mobilized thermal energy storage container

被引:36
作者
Guo, Shaopeng [1 ,2 ]
Zhao, Jun [2 ]
Wang, Weilong [3 ]
Jin, Guang [1 ]
Wang, Xiaotong [1 ]
An, Qingsong [2 ]
Gao, Wei [2 ]
机构
[1] Inner Mongolia Univ Sci & Technol, Sch Energy & Environm, Baotou 014010, Peoples R China
[2] Tianjin Univ, MOE, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300072, Peoples R China
[3] Sun Yat Sen Univ, Sch Engn, Guangzhou 510640, Guangdong, Peoples R China
关键词
Direct contact; Mobilized thermal energy storage system; Blocking; Electric heating; Phase change behavior; CHARGING PROCESS; PERFORMANCE; SIMULATION; BEHAVIORS; SYSTEM;
D O I
10.1016/j.applthermaleng.2014.12.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
As a promising technique of the waste heat recovery, the mobilized thermal energy storage (M-TES) can reduce the energy consumption and meet the heat demand for distributed users. With the convective heat transfer in the container, the direct contact M-TES shows a good charging and discharging performance except the blocking by the deposited phase change material (PCM) at the initial stage of the charging process. This paper studied a solution on forming the quick channels (QC) with electric heaters to solve the blocking issue. Phase change behaviors of PCM in the container with and without QC were analyzed and compared. With the QC formed with electric heaters, the charging time at the early and middle stage is obviously shortened compared with that of the experiment without electric heating. However, the solution is not suitable at later stage of charging because of the fading away of QC. The formation of QC takes about 90 s and covers around 5% of the thermal energy stored in the container. The results present that it is a good method to solve the blocking issue for the direct contact M-TES system especially with a low rate of heat release. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 18 条
[11]   Impact of phase change materials types and positioning on hot water tank thermal performance: Using measured water demand profile [J].
Nkwetta, Dan Nchelatebe ;
Vouillamoz, Pierre-Edouard ;
Haghighat, Fariborz ;
El-Mankibi, Mohamed ;
Moreau, Alain ;
Daoud, Ahmed .
APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) :460-468
[12]  
Wang W., 2010, Mobilized Thermal Energy Storage for Heat Recovery for Distributed Heating
[13]  
Wang W.L, 2011, INT C APPL EN PER IT
[14]   Preparation and performance of form-stable polyethylene glycol/silicon dioxide composites as solid-liquid phase change materials [J].
Wang, Weilong ;
Yang, Xiaoxi ;
Fang, Yutang ;
Ding, Jing .
APPLIED ENERGY, 2009, 86 (02) :170-174
[15]   A combined experimental and simulation study on charging process of Erythritol-HTO direct-blending based energy storage system [J].
Wang, Weilong ;
He, Shiquan ;
Guo, Shaopeng ;
Yan, Jinyue ;
Ding, Jing .
ENERGY CONVERSION AND MANAGEMENT, 2014, 83 :306-313
[16]   Experimental study on the direct/indirect contact energy storage container in mobilized thermal energy system (M-TES) [J].
Wang, Weilong ;
Guo, Shaopeng ;
Li, Hailong ;
Yan, Jinyue ;
Zhao, Jun ;
Li, Xun ;
Ding, Jing .
APPLIED ENERGY, 2014, 119 :181-189
[17]   Preparation and thermal properties of polyethylene glycol/expanded graphite blends for energy storage [J].
Wang, Weilong ;
Yang, Xiaoxi ;
Fang, Yutang ;
Ding, Jing ;
Yan, Jinyue .
APPLIED ENERGY, 2009, 86 (09) :1479-1483
[18]   Combined heat and power plant integrated with mobilized thermal energy storage (M-TES) system [J].
Wang W. ;
Hu Y. ;
Yan J. ;
Nyström J. ;
Dahlquist E. .
Frontiers of Energy and Power Engineering in China, 2010, 4 (4) :469-474