Commutability and interchangeability of commercial quality control materials with feline plasma for common biochemical analytes

被引:10
作者
Baral, Randolph M. [1 ,2 ]
Dhand, Navneet K. [2 ]
Freeman, Kathleen P. [3 ]
机构
[1] Paddington Cat Hosp, 210 Oxford St, Paddington, NSW 2021, Australia
[2] Univ Sydney, Fac Vet Sci, Sydney, NSW, Australia
[3] IDEXX Labs Ltd, Wetherby, England
关键词
Biochemistry analyzer; clinical chemistry; linear regression; Passing-Bablok; reference materials; residuals; REFERENCE INTERVALS; CLINICAL-CHEMISTRY; VALUES; SPECIFICATIONS; LABORATORIES; STRATEGIES; GUIDELINES; BREEDS;
D O I
10.1111/vcp.12357
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundSpecies-specific plasma or serum pools are considered the ideal standard material for quality control materials (QCM) instead of commercially available human QCM. However, using plasma or serum pools is limited by volume restrictions, degradation over time, and a narrow range of analyte concentrations. Concentrations of QCM analytes should be consistent or commutable with those from species-specific plasma/serum samples, and the precision from plasma pools should be comparable or interchangeable with commercial human QCM. ObjectivesThe aims of this study were to determine the commutability and interchangeability of 2 levels of commercial QCM (MAS chemTRAK-H [CT]) with feline plasma pools (PP) from normal and renal disease cats measured using a commercial laboratory analyzer and a veterinary in-house analyzer. MethodsAgreement between the 2 analyzers was assessed for 16 analytes by correlation and Passing-Bablok regression analyses of feline plasma samples. The difference between each CT data point and the regression line (residuals) was determined and standardized, and CT were considered commutable' with PP if the standardized residual was within a range of -3 to 3. Coefficients of variation (CVs) for CT and PP for 16 analytes on 2 analyzers were compared by bootstrap analysis to determine interchangeability. ResultsMost CT analytes were within the range of patient plasma sample analytes, thus commutable. Only 2 analytes had equivalent precision for both levels of CT and both levels of PP, and 5 additional analytes had similar precision for at least one level of CT compared to at least one level of PP. ConclusionsThe QCM assessed is commutable to feline PP within the tested ranges for 2 particular analyzers. Commutability does not grant interchangeability.
引用
收藏
页码:300 / 310
页数:11
相关论文
共 30 条
[1]   Assessing the coefficient of variations of chemical data using bootstrap method [J].
Amiri, Saeid ;
Zwanzig, Silvelyn .
JOURNAL OF CHEMOMETRICS, 2011, 25 (06) :295-300
[2]  
[Anonymous], TIETZ TXB CLIN CHEM
[3]   Towards common reference intervals in clinical chemistry -: An attempt at harmonization between three hospital laboratories in Skane, Sweden [J].
Bäck, SE ;
Nilsson, JE ;
Fex, G ;
Jeppson, JO ;
Rosén, U ;
Tryding, N ;
von Schenck, H ;
Norlund, L .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1999, 37 (05) :573-592
[4]   Biological variation and reference change values of feline plasma biochemistry analytes [J].
Baral, Randolph M. ;
Dhand, Navneet K. ;
Freeman, Kathleen P. ;
Krockenberger, Mark B. ;
Govendir, Merran .
JOURNAL OF FELINE MEDICINE AND SURGERY, 2014, 16 (04) :317-325
[5]   Pathology Harmony; a pragmatic and scientific approach to unfounded variation in the clinical laboratory [J].
Berg, Jonathan ;
Lane, Vanessa .
ANNALS OF CLINICAL BIOCHEMISTRY, 2011, 48 :195-197
[6]   Lack of commutability between a quality control material and plasma samples in a troponin I measurement system [J].
Candas-Estebanez, Beatriz ;
Cano-Corres, Ruth ;
Dot-Bach, Dolors ;
Valero-Politi, Jose .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (12) :2237-2238
[7]  
Ceriotti Ferruccio, 2007, Clin Biochem Rev, V28, P115
[8]  
Flatland B., 2013, ASVCP GUIDELINES QUA
[9]   ASVCP quality assurance guidelines: control of general analytical factors in veterinary laboratories [J].
Flatland, Bente ;
Freeman, Kathy P. ;
Friedrichs, Kristen R. ;
Vap, Linda M. ;
Getzy, Karen M. ;
Evans, Ellen W. ;
Harr, Kendal E. .
VETERINARY CLINICAL PATHOLOGY, 2010, 39 (03) :264-277
[10]   Impact of reference materials on accuracy in clinical chemistry [J].
Franzini, C ;
Ceriotti, F .
CLINICAL BIOCHEMISTRY, 1998, 31 (06) :449-457