Accelerometer based motion noise analysis of ECG signal

被引:0
|
作者
Han, D. K. [1 ,2 ]
Hong, J. H. [1 ]
Shin, J. Y. [1 ]
Lee, T. S. [1 ]
机构
[1] Chungbuk Natl Univ, Coll Med, Dept Biomed Engn, Cheongju, South Korea
[2] Eluji Univ, Dept Radiol Sci, Sungnam, South Korea
关键词
ECG; Motion noise; Accelerometer; Ubiquitous healthcares; ARTIFACT;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Continuous monitoring of an ECG signal is an important method to evaluate the subject's health state. However, there are many distortion factors in ECG signals, such as motion, respiration, and 60 Hz power noise, and EMI noise. Above all, motion is the most important factor in ECG signal distortion of moving subject and the baseline drift not only causes the estimation error of R-R interval, but changes ST segment level and results in diagnostic errors. The baseline drift removal algorithms without original ECG signal degradation are difficult to develop, because they affect the low frequency components in general. The accurate evaluation of ECG baseline drift must precede its removal. The main cause of baseline drift is the subject's motion, which can be evaluated by using small 3-axial accelerometer with accuracy and convenience. In this paper, baseline drift in ECG signal caused by motion artifact was quantitatively analyzed and evaluated by using 3-axial accelerometer and classifying gesture, posture, and dynamic motion. The baseline drift was influenced by respiration in static state and motion in dynamic state and the correlation between ECG and acceleration signal can be identified. The low frequency component of ECG baseline drift and high frequency component of acceleration signal were increased by motion and the facts were verified by correlation analysis. These results can be used to minimize the analysis error caused by motion. In addition, to apply baseline drift removal algorithm or not can be decided by the motion detection and the diagnostic error caused by the loss of low frequency component can be minimized. When this result is applied to the portable ECG device with a built-in accelerometer, subject's motion context information can be known and used to manage emergent situation.
引用
收藏
页码:198 / +
页数:2
相关论文
共 50 条
  • [21] Multidimensional Approaches for Noise Cancellation of ECG signal
    Bhoi, Akash Kumar
    Sherpa, Karma Sonam
    Phurailatpam, Devakishore
    Tamang, Jitendra Singh
    Giri, Pankaj Kumar
    2015 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2015, : 66 - 70
  • [22] A suppression of an impulsive noise in ECG signal processing
    Pander, TP
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 596 - 599
  • [23] Noise rejection method of wavelets for ECG signal
    Zhao, Guo-Liang
    Yang, Jun-Chun
    Sun, Shen
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2004, 25 (05): : 631 - 634
  • [24] SIGNAL-TO-NOISE RATIO OF RECORDED ECG
    KIRSNER, RLG
    MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (01): : 111 - &
  • [25] ECG signal denoising based on deep factor analysis
    Wang, Ge
    Yang, Lin
    Liu, Ming
    Yuan, Xin
    Xiong, Peng
    Lin, Feng
    Liu, Xiuling
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [26] Driving Fatigue Classified Analysis Based on ECG Signal
    Wu, Qun
    Zhao, Yangyang
    Bi, Xiangang
    2012 FIFTH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID 2012), VOL 2, 2012, : 544 - 547
  • [27] Analysis and Systematization of Noise Arising by Long-Term Recording of ECG Signal
    Altay, Yeldos A.
    Kremlev, Artem S.
    PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 1053 - 1057
  • [28] Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis
    Berwal, Deepak
    Vandana, C. R.
    Dewan, Sourya
    Jiji, C., V
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 12432 - 12442
  • [29] Kurtosis-based noise estimation and multiscale energy to denoise ECG signal
    Sharma, L. N.
    Dandapat, S.
    Mahanta, A.
    SIGNAL IMAGE AND VIDEO PROCESSING, 2013, 7 (02) : 235 - 245
  • [30] Kurtosis-based noise estimation and multiscale energy to denoise ECG signal
    L. N. Sharma
    S. Dandapat
    A. Mahanta
    Signal, Image and Video Processing, 2013, 7 : 235 - 245