Three-dimensional measurement of intervertebral kinematics in vitro using optical motion analysis

被引:7
|
作者
Holt, CA
Evans, SL
Dillon, D
Ahuja, S
机构
[1] Univ Wales Coll Cardiff, Sch Engn, Cardiff CF24 0YF, S Glam, Wales
[2] Univ Wales Hosp, Spinal Unit, Cardiff, Wales
关键词
three-dimensional kinematics; intervertebral kinematics; spine; spinal construct stiffness; anterior and posterior spine instrumentation; vertebrectomy;
D O I
10.1243/095441105X34374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Measurement of the stiffness of spinal motion segments is widely used for evaluating the stability of spinal implant constructs. A three-dimensional motion analysis technique has been developed that allows accurate measurement of the relative movement of the vertebral bodies about a well-defined anatomical axis system. The position of marker clusters on each vertebra is tracked using digital infrared cameras (Qualisys AB, Gothenburg). Landmarks are identified using a marked pointer, and an anatomical coordinate system is defined for each vertebra. The transformation relating the upper and lower vertebrae is calculated, using the joint coordinate system approach of Grood and Suntay to find the rotations and translations in each anatomical plane. The stiffness of vertebrectomy constructs was investigated using a Synex vertebral body replacement and an anterior rod with one or two screws in each vertebral body, with or without damage to the posterior longitudinal ligament (PLL). A moment of 2 N in was applied about each anatomical axis, and the range of motion about each axis was calculated. The range of motion in flexion-extension and lateral bending was significantly greater with only one screw. When the PLL was cut, there was no significant increase in the range of motion.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [31] Three-dimensional optical data storage using three-dimensional optics
    Kawata, Y
    Nakano, M
    Lee, SC
    OPTICAL ENGINEERING, 2001, 40 (10) : 2247 - 2254
  • [32] Three-Dimensional in Situ Temperature Measurement in Microsystems Using Brownian Motion of Nanoparticles
    Chung, Kwanghun
    Cho, Jae Kyu
    Park, Edward S.
    Breedveld, Victor
    Lu, Hang
    ANALYTICAL CHEMISTRY, 2009, 81 (03) : 991 - 999
  • [33] Three-dimensional motion analysis to assess cervical spine function - Measurement and reliability
    Schreiber, TU
    Smolenski, UC
    Seidel, EJ
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2001, 11 (04) : 113 - 122
  • [34] Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    Banks, SA
    Hodge, WA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 638 - 649
  • [35] Three-dimensional measurement of lumbar spine kinematics for fast bowlers in cricket
    Burnett, AF
    Barrett, CJ
    Marshall, RN
    Elliott, BC
    Day, RE
    CLINICAL BIOMECHANICS, 1998, 13 (08) : 574 - 583
  • [36] Capturing Three-Dimensional In Vivo Lumbar Intervertebral Joint Kinematics Using Dynamic Stereo-X-Ray Imaging
    Aiyangar, Ameet K.
    Zheng, Liying
    Tashman, Scott
    Anderst, William J.
    Zhang, Xudong
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [37] Motion Analysis of the Trapeziometacarpal Joint Using Three-dimensional Computed Tomography
    Kimura, Tetsuya
    Takai, Hiroaki
    Azuma, Tatsuo
    Sairyo, Koichi
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (01): : 78 - 84
  • [38] Three-Dimensional Target Motion Analysis Using Azimuth/Elevation Angles
    Badriasl, Laleh
    Dogancay, Kutluyil
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2014, 50 (04) : 3178 - 3194
  • [39] Analysis of three-dimensional motion of an object using a fixed monocular camera
    Quang, H
    Sato, M
    Tanaka, HT
    2ND INTERNATIONAL SYMPOSIUM ON 3D DATA PROCESSING, VISUALIZATION, AND TRANSMISSION, PROCEEDINGS, 2004, : 223 - 230
  • [40] Three-dimensional target motion analysis using angle and frequency measurements
    Becker, K
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2005, 41 (01) : 284 - 301