共 50 条
Experimental study of air-water two-phase flow in an 8 x 8 rod bundle under pool condition for one-dimensional drift-flux analysis
被引:59
|作者:
Chen, Shao-Wen
[1
]
Liu, Yang
[1
]
Hibiki, Takashi
[1
]
Ishii, Mamoru
[1
]
Yoshida, Yoshitaka
[2
]
Kinoshita, Ikuo
[2
]
Murase, Michio
[2
]
Mishima, Kaichiro
[2
]
机构:
[1] Purdue Univ, Sch Nucl Engn, W Lafayette, IN 47907 USA
[2] Inst Nucl Safety Syst Inc, Mihama, Fukui 9191205, Japan
关键词:
Scale effect;
Rod bundles;
Two-phase flow;
Pool conditions;
Void fraction;
LARGE-DIAMETER PIPE;
GAS-LIQUID FLOW;
VOID FRACTION;
NEURAL-NETWORKS;
VERTICAL TUBES;
MODEL;
INSTRUMENTATION;
D O I:
10.1016/j.ijheatfluidflow.2011.09.012
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
In order to establish a reliable rod bundle database under pool conditions and to benchmark the existing models, a well-scaled 8 x 8 rod bundle test loop was designed based on the scaling criteria and a series of experiments was carried out with adiabatic air-water two-phase flow. Experiments for pool conditions covered the area-averaged void fraction <alpha > range of 0.12-0.93. Existing models and experimental data including boiling and air-water two-phase flow were compared and analyzed. Experimental results show that differences exist between large and small casing rod bundles as the flow structure changes with the casing scale. In addition, traditional drift-flux models for pipes may reflect the casing scale effect, but cannot be directly applied to the rod bundle geometry in pool conditions. Among the existing models for rod bundles, the Murase's model (1986), Kamei's model (2008) and lshizuka's model (1995) give relatively better predictions in most regions. All benchmark results of existing models are tabulated in terms of void fraction prediction error for the present database. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:168 / 181
页数:14