Metal-free keratin modified poly(pyrrole-co-aniline)-reduced graphene oxide based nanocomposite materials: A promising cathode catalyst in microbial fuel cell application

被引:32
|
作者
Pattanayak, Prasanta [1 ]
Pramanik, Nilkamal [2 ]
Papiya, Farhan [1 ]
Kumar, Vikash [3 ]
Kundu, Patit Paban [1 ,4 ]
机构
[1] Univ Calcutta, Dept Polymer Sci & Technol, Adv Polymer Lab, 92 APC Rd, Kolkata 700009, India
[2] Indian Inst Sci IISc, Dept Biosyst Sci & Engn, Bengaluru, India
[3] Indian Inst Technol, Dept Civil & Environm Engn, Patna, Bihar, India
[4] Indian Inst Technol, Dept Chem Engn, Roorkee 247667, Uttar Pradesh, India
来源
关键词
Keratin (K); Reduced graphene oxide (rGO); S; N doped copolymer composites; Metal-free cathode catalyst; Oxygen reduction reaction (ORR); Microbial fuel cells (MFC); OXYGEN REDUCTION REACTION; DOPED CARBON NANOTUBES; HIGH-PERFORMANCE; FREE ELECTROCATALYSTS; MESOPOROUS CARBON; ELECTROCHEMICAL SUPERCAPACITORS; ELECTRODE MATERIALS; POWER-GENERATION; BLACK COMPOSITE; HUMAN HAIR;
D O I
10.1016/j.jece.2020.103813
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A metal-free N/S codoped carbon material "keratin" with poly(pyrrole-co-aniline) and reduced graphene oxide (rGO) is used as cathode catalyst in microbial fuel cells (MFCs). Experimentally, a waste material like keratin has been utilized to fabricate a cost-effective metal-free solid nanocomposite with higher electron conductivity. Poly (pyrrole-co-aniline) has been physisorbed over rGO via oxidative polymerization followed by keratinisation. The enhancements in catalytical active sites were observed due to the intrinsic nitrogen-sulfur (N/S) present in keratin backbone that indicated higher redox activity in the process. The three components i.e., keratin, poly (pyrrole-co-aniline) and rGO, synergistically enhanced the domain functionalities, e.g. electrical conductivity, path traversed for electron and ion transport for higher reduction currents in ORR. The novelty of this work has been underscored by different characterizations, where an enhanced cathodic current of - 0.676 mA at a potential 0.41 V were noted in cyclic voltamettric (CV)-ORR experiments. The electrochemical results revealed superior catalytic activity and higher stability of K-(PPy-Co-PANI)-rGO catalyst over other synthetic catalysts and Pt/C catalyst. In addition, these were tested in MFCs as cathode catalyst that showed an enhanced current density of 2062 mA/m(2) at a corresponding maximum power density of similar to 763 +/- 38 mW/m(2). In comparison, a superior power efficiency of about similar to 37, 32, 25 and 13 % were observed over Pt/C, (PPy-Co-PANI), K-(PPy-CoPANI) and (PPy-Co-PANI)-rGO catalyst, confirming the potential application of K-(PPy-Co-PANI)-rGO catalyst in MFCs. In a nutshell, the study describes the efficacy of K-(PPy-Co-PANI)-rGO nanocomposite as a cathode catalyst that can serve well than the commercially available Pt/C catalyst in MFCs.
引用
收藏
页数:15
相关论文
共 6 条
  • [1] Performance evaluation of poly(aniline-co-pyrrole) wrapped titanium dioxide nanocomposite as an air-cathode catalyst material for microbial fuel cell
    Pattanayak, Prasanta
    Papiya, Farhan
    Kumar, Vikash
    Singh, Amandeep
    Kundu, Patit Paban
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 118
  • [2] N/B Co-doped carbon as metal-free cathode catalyst for high-performance asymmetric neutral-alkaline microbial fuel cell
    Hu, Xi
    Chen, Kai
    Guo, Kexin
    Xiang, Lijuan
    Wen, Zhenhai
    Ci, Suqin
    ELECTROCHIMICA ACTA, 2021, 389
  • [3] Transition metal sulfide/oxide nanoflowers decorated on poly (aniline-2-sulfonic acid) modified polyacrylamide derived carbon cathode catalyst for bioenergy generation in microbial fuel cells
    Dhillon, Simran Kaur
    Kundu, Patit Paban
    ELECTROCHIMICA ACTA, 2023, 461
  • [4] A Review of Graphene-Based Nanostructural Materials for Both Catalyst Supports and Metal-Free Catalysts in PEM Fuel Cell Oxygen Reduction Reactions
    Zhou, Xuejun
    Qiao, Jinli
    Yang, Lin
    Zhang, Jiujun
    ADVANCED ENERGY MATERIALS, 2014, 4 (08)
  • [5] Label-free impedimetric immunosensor based on one-step co-electrodeposited poly-(pyrrole-co-pyrrole-1-propionic acid) and reduced graphene oxide polymer modified layer for the determination of melamine
    Gu, Ying
    Wang, Junping
    Pan, Mingfei
    Li, Shijie
    Fang, Guozhen
    Wang, Shuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 571 - 578
  • [6] Synthesis and Evaluation of Reduced Graphene Oxide (rGO) Supported on Ni3O4 as Spinel-Based Cathode Catalyst for the Effective Anion-Exchange Membrane Fuel Cell Application
    Santhosh Kumar, Ramasamy
    Gokulapriyan, Ramasamy
    Sakthivel, Venkitesan
    Sayfiddinov, Dilmurod
    Kim, Ae Rhan
    Arunkumar, Iyappan
    Yoo, Dong Jin
    CHEMCATCHEM, 2024, 16 (23)