Reliability of Measuring Insertion Depth in Cochlear Implanted Infants and Children Using Cochlear View Radiography

被引:3
作者
Noble, Anisha R. [1 ]
Christianson, Erin [2 ]
Norton, Susan J. [1 ,2 ,4 ]
Ou, Henry C. [1 ]
Phillips, Grace S. [3 ]
Khalatbari, Hedieh [3 ]
Friedman, Seth D. [3 ]
Horn, David L. [1 ,4 ]
机构
[1] Univ Washington, Dept Otolaryngol Head & Neck Surg, 1959 NE Pacific St,Suite 300, Seattle, WA 98195 USA
[2] Seattle Childrens Hosp, Childhood Commun Ctr, Seattle, WA USA
[3] Seattle Childrens Hosp, Dept Radiol, Seattle, WA USA
[4] Univ Washington, Dept Speech & Hearing Sci, Seattle, WA 98195 USA
关键词
cochlear implant; pediatric otology; insertion depth; PLACE-OF-STIMULATION; ELECTRODE INSERTION; BINAURAL FUSION; X-RAY; POSITION; LANGUAGE; SPEECH; RECOGNITION; PERFORMANCE; AGREEMENT;
D O I
10.1177/0194599820921857
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives Cochlear implant depth of insertion affects audiologic outcomes and can be measured in adults using plain films obtained in the "cochlear view." The objective of this study was to assess interrater and intrarater reliability of measuring depth of insertion using cochlear view radiography. Study Design Prospective, observational. Setting Tertiary referral pediatric hospital. Subjects and Methods Patients aged 11 months to 20 years (median, 4 years; interquartile range [IQR], 1-8 years) undergoing cochlear implantation at our institution were studied over 1 year. Children underwent cochlear view imaging on postoperative day 1. Films were deidentified and 1 image per ear was selected. Two cochlear implant surgeons and 2 radiologists evaluated each image and determined angular depth of insertion. Images were re-reviewed 6 weeks later by all raters. Inter- and intrarater reliability were calculated with intraclass correlation coefficients (ICCs). Results Fifty-seven ears were imaged from 42 children. Forty-nine ears (86%) had successful cochlear view x-rays. Median angular depth of insertion was 381 degrees (minimum, 272 degrees; maximum, 450 degrees; IQR, 360 degrees-395 degrees) during the first round of measurement. Measurements of the same images reviewed 6 weeks later showed median depth of insertion of 382 degrees (minimum, 272 degrees; maximum, 449 degrees; IQR, 360 degrees-397 degrees). Interrater and intrarater reliability ICCs ranged between 0.81 and 0.96, indicating excellent reliability. Conclusions Postoperative cochlear view radiography is a reliable tool for measurement of cochlear implant depth of insertion in infants and children. Further studies are needed to determine reliability of intraoperatively obtained cochlear view radiographs in this population.
引用
收藏
页码:822 / 828
页数:7
相关论文
共 42 条
[1]   Clinically Paired Electrodes Are Often Not Perceived as Pitch Matched [J].
Aronoff, Justin M. ;
Padilla, Monica ;
Stelmach, Julia ;
Landsberger, David M. .
TRENDS IN HEARING, 2016, 20
[2]   Quality control after insertion of the nucleus contour and contour advance electrode in adults [J].
Aschendorff, Antje ;
Kromeier, Jan ;
Klenzner, Thomas ;
Laszig, Roland .
EAR AND HEARING, 2007, 28 (02) :75S-79S
[3]   Interactions between cochlear implant electrode insertion depth and frequency-place mapping [J].
Baskent, D ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (03) :1405-1416
[4]  
Buchman CA, 2014, OTOL NEUROTOL, V35, P1773, DOI 10.1097/MAO.0000000000000541
[5]   Impact of Routine Plain X-ray on Postoperative Management in Cochlear Implantation [J].
Celik, Mehmet ;
Orhan, Kadir Serkan ;
Ozturk, Erkan ;
Avci, Hakan ;
Polat, Beldan ;
Guldiken, Yahya .
JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2018, 14 (03) :365-369
[6]  
Cohen LT, 1996, AM J OTOL, V17, P859
[7]   3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study [J].
De Seta, D. ;
Mancini, P. ;
Russo, F. Y. ;
Torres, R. ;
Mosnier, I. ;
Bensimon, J. L. ;
De Seta, E. ;
Heymann, D. ;
Sterkers, O. ;
Bernardeschi, D. ;
Nguyen, Y. .
ACTA OTORHINOLARYNGOLOGICA ITALICA, 2016, 36 (06) :499-505
[8]   Value of Routine Plain X-Ray Position Checks after Cochlear Implantation [J].
Dirr, Franziska ;
Hempel, John Martin ;
Krause, Eike ;
Mueller, Joachim ;
Berghaus, Alexander ;
Ertl-Wagner, Birgit ;
Braun, Thomas .
OTOLOGY & NEUROTOLOGY, 2013, 34 (09) :1666-1669
[9]   An electric frequency-to-place map for a cochlear implant patient with hearing in the nonimplanted ear [J].
Dorman, Michael F. ;
Spahr, Tony ;
Gifford, Rene ;
Loiselle, Louise ;
McKarns, Sharon ;
Holden, Timothy ;
Skinner, Margaret ;
Finley, Charles .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (02) :234-240
[10]   Effectiveness of skull X-RAY to determine cochlear implant insertion depth [J].
Fernandes, Vinay ;
Wang, Yiqiao ;
Yeung, Robert ;
Symons, Sean ;
Lin, Vincent .
JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2018, 47