Metamaterial microbolometers for multi-spectral infrared polarization imaging

被引:24
作者
Jiang, Shun [1 ]
Li, Jinzhao [1 ]
Li, Junyu [2 ]
Lai, Jianjun [3 ]
Yi, Fei [1 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China
[2] Yantai Raytron Technol Co Ltd, Yantai 264006, Peoples R China
[3] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect WNLO, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
PERFECT ABSORBERS; THIN-FILM; SENSOR; POLARIMETRY; DIVISION; OXIDE;
D O I
10.1364/OE.452981
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Vanadium oxide (VOx) microbolometers enable the construction of high-performance yet low-cost and uncooled imaging detectors in the mid-infrared spectrum. Typical microbolometers are broadband sensors with no polarization selectivity. Thus, imaging detectors based on microbolometers have to use separate spectral and polarization filters to select the target spectral bands and polarization states, and the resulting systems are complicated and bulky. Here we demonstrate that by using metamaterial absorbers (MAs), which are arrays of optical resonators with sub-wavelength dimensions and spacing, we simultaneously tailor the VOx microbolometers' spectral and polarization responses, the need for separate spectral filters and polarizers can be mitigated. The MAs selectively absorb the TM polarization component of the incident light in a spectral band with tunable central wavelength and bandwidth while rejecting the TE polarization component. Two MAs with average TM absorption of 0.8322 in the 5.150 mu m - 6.422 mu m band and 0.7720 in the 5.867 mu m - 7.467 mu m band are fabricated, and the polarization extinction ratio (PER) are 42.24 and 42.65, respectively. The MAs are applied to VOx micro-bolometers, and the measured detector responses agree well with the absorption spectra of the MAs. The achieved peak responsivities of two fabricated detectors are 1.0 V/W at 6.0 mu m and 1.46 V/W at 6.8 mu m, respectively. And the two detectors achieve a D* of 6.94x10(5) cm.Hz(1/2)W(-1) at 11 Hz and 9.95x10(5) cm.Hz(1/2)W(-1) at 36Hz, respectively. Our work paved the way towards large format room temperature multi-spectral infrared polarization imaging detector. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing
引用
收藏
页码:9065 / 9087
页数:23
相关论文
共 67 条
  • [1] Measurement of the polarization state of light using an integrated plasmonic polarimeter
    Afshinmanesh, Farzaneh
    White, Justin S.
    Cai, Wenshan
    Brongersma, Mark L.
    [J]. NANOPHOTONICS, 2012, 1 (02) : 125 - 129
  • [2] Photodetection Using Atomically Precise Graphene Nanoribbons
    Alavi, Seyed Khalil
    Senkovskiy, Boris, V
    Hertel, Dirk
    Haberer, Danny
    Ando, Yoichi
    Meerholz, Klaus
    Fischer, Felix R.
    Grueneis, Alexander
    Lindfors, Klas
    [J]. ACS APPLIED NANO MATERIALS, 2020, 3 (08): : 8343 - 8351
  • [3] Polarization Imaging: Principles and Integrated Polarimeters
    Andreou, Andreas G.
    Kalayjian, Zaven Kevork
    [J]. IEEE SENSORS JOURNAL, 2002, 2 (06) : 566 - 576
  • [4] Large scale infrared imaging of tissue micro arrays (TMAs) using a tunable Quantum Cascade Laser (QCL) based microscope
    Bassan, Paul
    Weida, Miles J.
    Rowlette, Jeremy
    Gardner, Peter
    [J]. ANALYST, 2014, 139 (16) : 3856 - 3859
  • [5] Charles M. H., 1992, PROCSPIE, V1735, P1
  • [6] Pyxis® handheld polarimetric imager
    Chenault, David B.
    Pezzaniti, J. Larry
    Vaden, Justin P.
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XLII, 2016, 9819
  • [7] A thin film broadband absorber based on multi-sized nanoantennas
    Cui, Yanxia
    Xu, Jun
    Fung, Kin Hung
    Jin, Yi
    Kumar, Anil
    He, Sailing
    Fang, Nicholas X.
    [J]. APPLIED PHYSICS LETTERS, 2011, 99 (25)
  • [8] Hole Array Perfect Absorbers for Spectrally Selective Midwavelength Infrared Pyroelectric Detectors
    Dao, Thang Duy
    Ishii, Satoshi
    Yokoyama, Takahiro
    Sawada, Tomomi
    Sugavaneshwar, Ramu Pasupathi
    Chen, Kai
    Wada, Yoshiki
    Nabatame, Toshihide
    Nagao, Tadaaki
    [J]. ACS PHOTONICS, 2016, 3 (07): : 1271 - 1278
  • [9] Dennis H. G., 2002, PROCSPIE
  • [10] Dmitry V., 2014, PROCSPIE