Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine

被引:41
作者
Nguyen, Lee S. [1 ]
Squara, Pierre [1 ]
机构
[1] CMC Ambroise Pare, Crit Care Med Dept, Neuilly Sur Seine, France
关键词
non-invasive monitoring; cardiac output; hemodynamics; critical care medicine; bioreactance; THORACIC ELECTRICAL BIOIMPEDANCE; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; ILL PATIENTS; PULSE-WAVE; TRANSTHORACIC BIOIMPEDANCE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER ULTRASOUND; THERMODILUTION; ACCURACY;
D O I
10.3389/fmed.2017.00200
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.
引用
收藏
页数:8
相关论文
共 71 条
[1]   Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure [J].
Albert, NM ;
Hail, MD ;
Li, JB ;
Young, JB .
AMERICAN JOURNAL OF CRITICAL CARE, 2004, 13 (06) :469-479
[2]   Accuracy of Noninvasive Estimated Continuous Cardiac Output (esCCO) Compared to Thermodilution Cardiac Output: A Pilot Study in Cardiac Patients [J].
Ball, Timothy R. ;
Tricinella, Anthony P. ;
Kimbrough, Alex ;
Luna, Sarah ;
Gloyna, David F. ;
Villamaria, Frank J. ;
Culp, William C., Jr. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) :1128-1132
[3]   Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization [J].
Barin, E ;
Haryadi, DG ;
Schookin, SI ;
Westenskow, DR ;
Zubenko, VG ;
Beliaev, KR ;
Morozov, AA .
CRITICAL CARE MEDICINE, 2000, 28 (03) :698-702
[4]   Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients [J].
Ben N Barry ;
Abhiram Mallick ;
Andrew R Bodenham ;
Michael Vucevic .
Critical Care, 1 (2)
[5]   USE OF ISO-SHUNT LINES FOR CONTROL OF OXYGEN-THERAPY [J].
BENATAR, SR ;
HEWLETT, AM ;
NUNN, JF .
BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (07) :711-718
[6]   Ability of esCCO to track changes in cardiac output [J].
Biais, M. ;
Berthezene, R. ;
Petit, L. ;
Cottenceau, V. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) :403-410
[7]   Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients [J].
Biais, Matthieu ;
Cottenceau, Vincent ;
Petit, Laurent ;
Masson, Francoise ;
Cochard, Jean-Francois ;
Sztark, Francois .
CRITICAL CARE, 2011, 15 (04)
[8]   Noninvasive monitoring of cardiac output in critically ill patients with thoracocardiography [J].
Bloch, KE ;
Baumann, PC ;
Stocker, R ;
Russi, EW .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) :26-31
[9]   Thoracocardiography: Noninvasive monitoring of left ventricular stroke volume [J].
Bloch, KE ;
Jugoon, S ;
de Socarraz, H ;
Manning, K ;
Sackner, MA .
JOURNAL OF CRITICAL CARE, 1998, 13 (03) :146-157
[10]  
Boyle M, 2009, CRIT CARE RESUSC, V11, P198