Hip resurfacing generates a more physiological gait than total hip replacement: A case-control study

被引:10
作者
Maillot, Cedric [1 ]
Auvinet, Edouard [1 ]
Harman, Ciara [2 ]
Cobb, Justin [1 ]
Riviere, Charles [1 ,2 ]
机构
[1] Imperial Coll London, MSK Lab, Lab Block,White City Campus, London W12 0BZ, England
[2] South West London Elect Orthopaed Ctr, Dorking Rd, Epsom KT18 7EG, Surrey, England
关键词
Hip replacement; Hip resurfacing; Gait analysis; Symmetry index; Kinematic alignment; FEMORAL OFFSET; ARTHROPLASTY; THA; RESTORATION; ANTEVERSION; PARAMETERS; ALIGNMENT; PATTERNS; POSITION; IMPLANT;
D O I
10.1016/j.otsr.2019.12.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Restoration of the constitutional joint anatomy after hip replacement favours physiological peri-articular soft-tissue tension and kinematics, and is likely to be functionally beneficial. Hip resurfacing (HR) and conventional total hip replacement (THR) are two different options for replacing degenerated hips, and are likely to result in different anatomical reconstruction. We initiated this study to investigate the differences in gait performance between these two prosthetic options, and aimed to answer the following questions: (1) does HR result in better restoration of the frontal hip anatomical parameters, (2) and generate a more physiological gait compared to THR? (3) Does the quality of the anatomical restoration after THR influence gait performance? Hypotheses: Our hypothesis was that a better anatomical restoration using HR versus THR would produce more physiological (symmetric) gait. Methods: We retrospectively reviewed 52 patients who had unilateral primary osteoarthritis successfully treated by replacement (40 THRs and 12 HRs). Hip anatomical parameters were measured on standing pelvic radiographs on both the prosthetic and the contralateral healthy hips. Patients undertook gait assessment under both normal and stress conditions at a mean follow-up of 14 months (7 to 16 months). Gait performances were compared between HR and THR, and the relationship between gait performances and quality of frontal anatomical restoration (estimated on radiograph) were assessed. Results: Compared to the native contralateral side, the HR procedure tended to decrease all independent anatomical radiographic parameters with the exception of the vertical centre of rotation offset, whilst the THR procedure tended to increase them; the difference between HR and THR was only statistically significant for femoral offset and global horizontal offset (increased after THR while reduced after HR). Only 50% of THR and 25% of HR procedures closely anatomically (+/- 15%) recreated both global horizontal offset and global vertical offset. Under normal conditions (normal walking speed and flat ramp), the gait was fairly symmetric for both the HR and the THR patients with a symmetry index of 0.62% and 3.14% respectively. At high walking speed (stress conditions), the symmetry index degraded for both groups, but the gait remained more symmetric in the HR group (2.09%), compared to the THR group (5.74%); nevertheless, the difference remained not statistically significant (p = 0.159). We were unable to detect any significant relationship between gait performances and radiographically measured hip frontal anatomical parameters. Discussion/conclusions: HR procedure is more consistent than conventional THR in generating a more physiological gait under stress conditions. Radiographic estimation of the quality of the frontal anatomical hip restoration is of poor value to predict gait performances of THR patients. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:527 / 534
页数:8
相关论文
共 50 条
  • [41] Short stems reproduce femoral offset better than standard stems in total hip arthroplasty: a case-control study
    Roger Erivan
    Anne-Sophie Muller
    Guillaume Villatte
    Stéphane Millerioux
    Aurélien Mulliez
    Stéphane Boisgard
    Stéphane Descamps
    International Orthopaedics, 2020, 44 : 45 - 51
  • [42] Short stems reproduce femoral offset better than standard stems in total hip arthroplasty: a case-control study
    Erivan, Roger
    Muller, Anne-Sophie
    Villatte, Guillaume
    Millerioux, Stephane
    Mulliez, Aurelien
    Boisgard, Stephane
    Descamps, Stephane
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (01) : 45 - 51
  • [43] Complications and mid to long term outcomes for hip resurfacing versus total hip replacement: a systematic review and meta-analysis
    Kumar, Prasoon
    Ksheersagar, Vivek
    Aggarwal, Sameer
    Jindal, Karan
    Dadra, Ankit
    Kumar, Vishal
    Patel, Sandeep
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (05) : 1495 - 1504
  • [44] GAIT ANALYSIS IN THE ASSESSMENT OF PATIENTS UNDERGOING A TOTAL HIP REPLACEMENT
    Regazzoni, Daniele
    Vitali, Andrea
    Zefinetti, Filippo Colombo
    Rizzi, Caterina
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 14, 2020,
  • [45] Direct anterior approach with conventional instruments versus robotic posterolateral approach in elective total hip replacement for primary osteoarthritis: a case-control study
    Alessio-Mazzola, Mattia
    Colombo, Pietro
    Barducci, Niccolo'
    Ghezzi, Elena
    Zagra, Luigi
    Caldora, Patrizio
    Ometti, Marco
    Placella, Giacomo
    Salini, Vincenzo
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [46] Is the economic and social cost of one-stage bilateral hip resurfacing lower than two-stage procedures? Retrospective case-control study of 260 hips
    Hoestlandt, Antoine
    Dartus, Julien
    Delay, Cyril
    Martinot, Pierre
    Girard, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (03) : 535 - 542
  • [47] Postural control in patients with total hip replacement
    Calo, L.
    Rabini, A.
    Picciotti, P. M.
    Laurino, S.
    Passali, G. C.
    Ferrara, P. E.
    Maggi, L.
    Piazzini, D. B.
    Specchia, A.
    Frasca, G.
    Ronconi, G.
    Bertolini, C.
    Scarano, E.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2009, 45 (03) : 327 - 333
  • [48] Hip resurfacing requires larger acetabular cups than conventional hip replacement: A comparative analysis of 100 hips, based on radiographic templating
    Schmidutz, Florian
    Fottner, Andreas
    Wanke-Jellinek, Lorenz
    Steinbrueck, Arnd
    Jansson, Volkmar
    Mazzochian, Farhad
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (04): : 484 - 491
  • [49] Cost-Utility of Metal-on-Metal Hip Resurfacing Compared to Conventional Total Hip Replacement in Young Active Patients with Osteoarthritis
    Heintzbergen, Sanne
    Kulin, Nathalie A.
    IJzerman, Maarten J.
    Steuten, Lotte M. G.
    Werle, Jason
    Khong, Hoa
    Marshall, Deborah A.
    VALUE IN HEALTH, 2013, 16 (06) : 942 - 952
  • [50] Changes in bone mineral density in the proximal femur after hip resurfacing and uncemented total hip replacement A PROSPECTIVE RANDOMISED CONTROLLED STUDY
    Smolders, J. M. H.
    Hol, A.
    Rijnders, T.
    van Susante, J. L. C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11): : 1509 - 1514