Hip resurfacing generates a more physiological gait than total hip replacement: A case-control study

被引:10
作者
Maillot, Cedric [1 ]
Auvinet, Edouard [1 ]
Harman, Ciara [2 ]
Cobb, Justin [1 ]
Riviere, Charles [1 ,2 ]
机构
[1] Imperial Coll London, MSK Lab, Lab Block,White City Campus, London W12 0BZ, England
[2] South West London Elect Orthopaed Ctr, Dorking Rd, Epsom KT18 7EG, Surrey, England
关键词
Hip replacement; Hip resurfacing; Gait analysis; Symmetry index; Kinematic alignment; FEMORAL OFFSET; ARTHROPLASTY; THA; RESTORATION; ANTEVERSION; PARAMETERS; ALIGNMENT; PATTERNS; POSITION; IMPLANT;
D O I
10.1016/j.otsr.2019.12.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Restoration of the constitutional joint anatomy after hip replacement favours physiological peri-articular soft-tissue tension and kinematics, and is likely to be functionally beneficial. Hip resurfacing (HR) and conventional total hip replacement (THR) are two different options for replacing degenerated hips, and are likely to result in different anatomical reconstruction. We initiated this study to investigate the differences in gait performance between these two prosthetic options, and aimed to answer the following questions: (1) does HR result in better restoration of the frontal hip anatomical parameters, (2) and generate a more physiological gait compared to THR? (3) Does the quality of the anatomical restoration after THR influence gait performance? Hypotheses: Our hypothesis was that a better anatomical restoration using HR versus THR would produce more physiological (symmetric) gait. Methods: We retrospectively reviewed 52 patients who had unilateral primary osteoarthritis successfully treated by replacement (40 THRs and 12 HRs). Hip anatomical parameters were measured on standing pelvic radiographs on both the prosthetic and the contralateral healthy hips. Patients undertook gait assessment under both normal and stress conditions at a mean follow-up of 14 months (7 to 16 months). Gait performances were compared between HR and THR, and the relationship between gait performances and quality of frontal anatomical restoration (estimated on radiograph) were assessed. Results: Compared to the native contralateral side, the HR procedure tended to decrease all independent anatomical radiographic parameters with the exception of the vertical centre of rotation offset, whilst the THR procedure tended to increase them; the difference between HR and THR was only statistically significant for femoral offset and global horizontal offset (increased after THR while reduced after HR). Only 50% of THR and 25% of HR procedures closely anatomically (+/- 15%) recreated both global horizontal offset and global vertical offset. Under normal conditions (normal walking speed and flat ramp), the gait was fairly symmetric for both the HR and the THR patients with a symmetry index of 0.62% and 3.14% respectively. At high walking speed (stress conditions), the symmetry index degraded for both groups, but the gait remained more symmetric in the HR group (2.09%), compared to the THR group (5.74%); nevertheless, the difference remained not statistically significant (p = 0.159). We were unable to detect any significant relationship between gait performances and radiographically measured hip frontal anatomical parameters. Discussion/conclusions: HR procedure is more consistent than conventional THR in generating a more physiological gait under stress conditions. Radiographic estimation of the quality of the frontal anatomical hip restoration is of poor value to predict gait performances of THR patients. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:527 / 534
页数:8
相关论文
共 50 条
  • [31] Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing
    Matthies, A.
    Underwood, R.
    Cann, P.
    Ilo, K.
    Nawaz, Z.
    Skinner, J.
    Hart, A. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03): : 307 - 314
  • [32] Total hip replacement: A case history
    Keston, VJ
    Enthoven, AC
    HEALTH CARE MANAGEMENT REVIEW, 1998, 23 (01) : 7 - 17
  • [33] European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing
    Hannemann, F.
    Hartmann, A.
    Schmitt, J.
    Luetzner, J.
    Seidler, A.
    Campbell, P.
    Delaunay, C. P.
    Drexler, H.
    Ettema, H. B.
    Garcia-Cimbrelo, E.
    Huberti, H.
    Knahr, K.
    Kunze, J.
    Langton, D. J.
    Lauer, W.
    Learmonth, I.
    Lohmann, C. H.
    Morlock, M.
    Wimmer, M. A.
    Zagra, L.
    Guenther, K. P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (03) : 263 - 271
  • [34] Comparison of revision risks and complication rates between total HIP replacement and HIP resurfacing within the similar age group
    Eethakota, Veera Venkata Satyanarayana
    Vaishnav, Vinod
    Johnston, Linda
    Abboud, Rami
    Wang, Weijie
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2018, 16 (06): : 339 - 349
  • [35] Is There Safety Outside the "Safe Zone" in Total Hip Replacement? A Retrospective Observational Study
    Stepinski, Piotr
    Jegierski, Dawid
    Maciag, Grzegorz
    Maciag, Bartosz
    Adamska, Olga
    Stolarczyk, Artur
    MEDICINA-LITHUANIA, 2024, 60 (05):
  • [36] Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
    Aminian, K
    Trevisan, C
    Najafi, B
    Dejnabadi, H
    Frigo, C
    Pavan, E
    Telonio, A
    Cerati, F
    Marinoni, EC
    Robert, P
    Leyvraz, PF
    GAIT & POSTURE, 2004, 20 (01) : 102 - 107
  • [37] A comparison of leg length and femoral offset discrepancies in hip resurfacing, large head metal-on- metal and conventional total hip replacement: a case series
    Katie A Herman
    Alan J Highcock
    John D Moorehead
    Simon J Scott
    Journal of Orthopaedic Surgery and Research, 6
  • [38] Patient-reported outcome following metal-on-metal resurfacing of the hip and total hip replacement
    Hall, David P.
    Srikantharajah, Del
    Anakwe, Raimond E.
    Gaston, Paul
    Howie, Colin R.
    HIP INTERNATIONAL, 2009, 19 (03) : 245 - 250
  • [39] Total knee replacement on more than 20° valgus: A case control study
    Putman, Sophie
    Ehlinger, Matthieu
    Tillie, Bruno
    Puliero, Benjamin
    Ramdane, Nassima
    Remy, Franck
    Pasquier, Gilles
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (04) : 613 - 617
  • [40] Relative Importance of Gait vs. Joint Positioning on Hip Contact Forces after Total Hip Replacement
    Foucher, Kharma C.
    Hurwitz, Debra E.
    Wimmer, Markus A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (12) : 1576 - 1582