Electrochemical hematocrit determination in a direct current microfluidic device

被引:20
作者
Lee, Hwi Yong [1 ]
Barber, Cedrick [1 ]
Rogers, Jessika A. [1 ]
Minerick, Adrienne R. [1 ]
机构
[1] Michigan Technol Univ, Dept Chem Engn, Houghton, MI 49931 USA
基金
美国国家科学基金会;
关键词
Hematocrit; Medical diagnostics; Microdevice; Platinum electrodes; Red blood cell; ERYTHROCYTE-MEMBRANE; HUMAN-BLOOD; TRITON X-100; BODY-TISSUES; RESISTANCE; CELL; RESISTIVITY; HEMOGLOBIN; HEMOLYSIS; SOLUBILIZATION;
D O I
10.1002/elps.201400466
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hematocrit (HCT) tests are widely performed to screen blood donors and to diagnose medical conditions. Current HCT test methods include conventional microhematocrit, Coulter counter, CuSO4 specific gravity, and conductivity-based point-of-care (POC) HCT devices, which can be either expensive, environmentally inadvisable, or complicated. In the present work, we introduce a new and simple microfluidic system for a POC HCT determination. HCT was determined by measuring current responses of blood under 100V DC for 1 min in a microfluidic device containing a single microchannel with dimensions of 180m by 70m and 10mm long. Current responses of red blood cell (RBC) suspensions in PBS or separately plasma at HCT concentrations of 10, 20, 25, 30, 35, 40, 45, 50, 55, 60, and 70 vol% were measured to show feasibility of the microfluidic system for HCT determination. Key parameters affecting current responses included electrolysis bubbles and irreversible RBC adsorption; parameters were optimized via addition of nonionic surfactant Triton X-100 into sample solution and carbonizing electrode surfaces. The linear trend line of current responses over a range of RBC concentrations were obtained in both PBS and plasma. This work suggested that a simple microfluidic device could be a promising platform for a new POC HCT device.
引用
收藏
页码:978 / 985
页数:8
相关论文
共 53 条
  • [1] 2-TYPES OF HEMOLYTIC-ACTIVITY OF DETERGENTS
    BIELAWSKI, J
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1035 (02) : 214 - 217
  • [2] Monitoring of the Zeta Potential of Human Cells upon Reduction in Their Viability and Interaction with Polymers
    Bondar, O. V.
    Saifullina, D. V.
    Shakhmaeva, I. I.
    Mavlyutova, I. I.
    Abdullin, T. I.
    [J]. ACTA NATURAE, 2012, 4 (01): : 78 - 81
  • [3] SPECIFIC ELECTRIC RESISTANCE OF BODY TISSUES
    BURGER, HC
    VANDONGEN, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1961, 5 (04) : 431 - &
  • [4] Burger HC, 1943, ACTA MED SCAND, V114, P584
  • [5] HEMOGLOBIN DETERMINATION IN BLOOD-DONORS
    CABLE, RG
    [J]. TRANSFUSION MEDICINE REVIEWS, 1995, 9 (02) : 131 - 144
  • [6] Commercialization of microfluidic point-of-care diagnostic devices
    Chin, Curtis D.
    Linder, Vincent
    Sia, Samuel K.
    [J]. LAB ON A CHIP, 2012, 12 (12) : 2118 - 2134
  • [7] Cole S. C., 1972, Membranes, Ions and Impulses A Chapter of Classical Biophysics
  • [8] ENGSTROM RC, 1983, J AM CHEM SOC, V105, P7211
  • [9] Fernandes Heloise Pöckel, 2011, Rev. Bras. Hematol. Hemoter., V33, P297, DOI 10.5581/1516-8484.20110080
  • [10] Fernandez A J, 1985, Spec Care Dentist, V5, P264, DOI 10.1111/j.1754-4505.1985.tb00591.x