Improving the follow up after EVAR by using ultrasound image fusion of CEUS and MS-CT

被引:29
作者
Clevert, D. A. [1 ]
Helck, A.
D'Anastasi, M.
Guertler, V.
Sommer, W. H.
Meimarakis, G. [2 ]
Weidenhagen, R. [2 ]
Reiser, M.
机构
[1] Univ Munich, Dept Clin Radiol, Interdisciplinary Ultrasound Ctr, D-81377 Munich, Germany
[2] Univ Munich, Dept Surg, D-81377 Munich, Germany
关键词
Aortic aneurysm; EVAR; ultrasonography; CEUS; image fusion; ENDOVASCULAR ANEURYSM REPAIR; CONTRAST-ENHANCED ULTRASOUND; ABDOMINAL AORTIC-ANEURYSM; ENDOLEAKS; SURVEILLANCE; SONOVUE;
D O I
10.3233/CH-2011-1460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate whether the image fusion with contrast enhanced ultrasound (CEUS) and CT affects the diagnosis of endoleaks in unclear cases. Methods and materials: 35 patients with follow-up examinations after enodvascular aneurysm repair (EVAR) were included in this retrospective study. Mean patient age was 73 years (range 54-83 y). B-scan, colour doppler and CEUS (1.2 ml SonoVue (R), Bracco Imaging Germany) were performed in all patients by an experienced examiner using two different high-end ultrasound system (Siemens ACUSON S2000 (TM), Siemens Healthcare, Erlangen, Germany or Logic E9, GE Healthcare, Milwaukee, WI, USA) with a multifrequency curved array transducer. The examiner was initially blinded to the CT results. Additional image fusion with CT-angiography (CTA) was then performed. The ultrasound examinations were later read by two blinded unbiased investigators with more than five years of clinical ultrasound in consensus. Results: All patients were examined using all diagnostic ultrasound tools of the study. The results show that image fusion is easy and convenient to perform. Conventional ultrasound examination with B-scan and colour Doppler examination detected one Type I and one Type II endoleak, contrast enhanced ultrasound detected one Type I and three Type II endoleaks after EVAR whereas CTA depicted one Type I and two Type II endoleaks. Ultrasound image fusion with CT-angiography confirmed one Type I and three Type II endoleaks. Conclusion: In comparison to conventional ultrasound and CTA the use of CEUS improved the visualization and classification of endoleaks. CEUS shows even small blood flow which can be depicted due to the real time imaging of endoleaks. In unclear cases additional ultrasound image fusion with CEUS and CT angiography improves the visualisation of small endoleaks and this may cause a change in the follow-up interval. CEUS is a good alternative to CT in the detection and follow-up of endoleaks, especially in patients with contraindications to CT contrast agents due to allergies or renal failure, enabling reduced additional costs and exposure to radiation.
引用
收藏
页码:91 / 104
页数:14
相关论文
共 31 条
  • [2] Arko FR, 2001, J ENDOVASC THER, V8, P503, DOI 10.1583/1545-1550(2001)008<0503:TIEFEA>2.0.CO
  • [3] 2
  • [4] Ultrasound imaging with SonoVue: Low mechanical index real-time imaging
    Bauer, A
    Solbiati, L
    Weissman, N
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S282 - S284
  • [5] Baum R A, 2001, Tech Vasc Interv Radiol, V4, P222, DOI 10.1053/tvir.2001.31536
  • [6] Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms:: Preliminary experience
    Carrafiello, Gianpaolo
    Lagana, Domenico
    Recaldini, Chiara
    Mangini, Monica
    Bertolotti, Elena
    Caronno, Roberto
    Tozzi, Matteo
    Piffaretti, Gabriele
    Genovese, Eugenio Annibale
    Fugazzola, Carlo
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) : 969 - 974
  • [7] Endoleak after endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    Faruqi, RM
    Sawhney, R
    Reilly, LM
    Kerlan, RB
    Canto, CJ
    Lukaszewicz, GC
    LaBerge, JM
    Wilson, MW
    Gordon, RL
    Wall, SD
    Rapp, J
    Messina, LM
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 34 (01) : 98 - 105
  • [8] Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair
    Clevert, D. -A.
    Minaifar, N.
    Weckbach, S.
    Kopp, R.
    Meimarakis, G.
    Clevert, D. -A.
    Reiser, M.
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2008, 39 (1-4) : 121 - 132
  • [9] Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS). A pictorial comparison with CTA
    Clevert, D. -A.
    Minaifar, N.
    Kopp, R.
    Stickel, M.
    Meimarakis, G.
    Sommer, W.
    Reiser, M.
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (03) : 151 - 168
  • [10] Clevert D.A., 2011, GEFASSCHIRU IN PRESS