Development of Chromium(III) Selective Potentiometric Sensors for Its Determination in Petroleum Water Samples Using Synthesized Nano Schiff Base Complex as an Ionophore

被引:6
作者
Ali, Tamer Awad [1 ]
Mohamed, Gehad G. [2 ]
机构
[1] Egyptian Petr Res Inst EPRI, Cairo 11727, Egypt
[2] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
关键词
WALLED CARBON NANOTUBES; SCREEN-PRINTED ELECTRODE; LIQUID-CHROMATOGRAPHY; ION; NANOPARTICLES; SURFACTANT; FRAMEWORK; BROMIDE;
D O I
10.1093/jaoacint/qsab166
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Many analytical techniques, such as X-ray fluorescence spectrometry, inductively coupled plasma-atomic emission spectrometry, and even traditional spectroscopic and fluorimetric methods, are used for the measurement of Cr(III) ions. These methods are sophisticated and very expensive, so the cheapest and low-cost ion selective electrodes were used. Objective The quantification of Cr(III) ions in various samples of petroleum water using ion selective electrodes was suggested. Nano chromium modified carbon paste sensor (MCPE) and nano chromium modified screen printed sensor (MSPE) based on Schiff base Cr(III) complex are developed. Method The developed nano Cr(III) Schiff base chelate was characterized using elemental, spectroscopic, and thermal analysis techniques. The proposed nano Cr(III) has good properties for antibacterial and antifungal activity. The modified carbon paste and screen-printed sensors were fabricated for determination of Cr(III) ion. Results The proposed MCPE (sensor I) and MSPE (sensor II) obeys Nernstian equation upon incorporating nano Cr(III) ionophore in the paste at 25 degrees C with a trivalent cationic slope of 18.8 +/- 0.2 and 20.0 +/- 0.4 mV/decade. They have showed fast response time around 8 and 5 s, and they may be used for at least 98 and 240 days without significant changes in MCPE and MSPE potential, respectively. The sensors I and II showed good selectivity for Cr(III) ion toward a wide variety of metal ions or anions as confirmed by potentiometric selectivity coefficients values. The detection and quantification limits were defined alongside the other process validation parameters. The results have been compared well to those obtained by atomic absorption spectrometry (AAS), and the data of F- and t-test indicated no significant difference between the proposed and AAS methods. Conclusions These sensors have been used to determine Cr(III) ions in genuine spiked different petroleum well water samples with satisfactory percentage recoveries, low standard, and relative standard deviation values using direct potentiometric and standard addition methods. The proposed method of producing nano Cr(III) complex as a sensor material possesses the distinct advantages of being simple, easily reproducible, appropriate for operation, and highly selective and sensitive.
引用
收藏
页码:727 / 738
页数:12
相关论文
共 54 条
[1]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[2]  
Abdou A.A., 2018, EGYPT J PET, V27, P739, DOI [10.1016/j.ejpe.2017.11.001, DOI 10.1016/J.EJPE.2017.11.001]
[3]   Highly sensitive potentiometric sensors for thorium ions detection using morpholine derivative self-assembled on silver nanoparticles [J].
Akl, Zeinab F. ;
Ali, Tamer Awad .
RSC ADVANCES, 2016, 6 (81) :77854-77862
[4]   A novel modified screen-printed electrode with triazole surfactant assembled on silver nanoparticles for potentiometric determination of uranium [J].
Akl, Zeinab Farouk ;
Ali, Tamer Awad .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 314 (03) :1865-1875
[5]   Screen printed ion selective electrodes based on self-assembled thiol surfactant-gold-nanoparticles for determination of Cu(II) in different water samples [J].
Ali, Tamer Awad ;
Abd-Elaal, Ali A. ;
Mohamed, Gehad G. .
MICROCHEMICAL JOURNAL, 2021, 160
[6]   Construction and characterization of nano iron complex ionophore for electrochemical determination of Fe(III) in pure and various real water samples [J].
Ali, Tamer Awad ;
Mahmoud, Walaa H. ;
Mohamed, Gehad G. .
APPLIED ORGANOMETALLIC CHEMISTRY, 2019, 33 (11)
[7]   Manufacture of Lead-Specific Screen-Printed Sensor Based on Lead Schiff Base Complex as Carrier and Multi-Walled Carbon Nanotubes for Detection of Pb(II) in Contaminated Water Tests [J].
Ali, Tamer Awad ;
Hassan, Abeer M. E. ;
Mohamed, Gehad G. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12) :10732-10747
[8]   Modified Screen-Printed Ion Selective Electrodes for Potentiometric Determination of Sodium Dodecylsulfate in Different Samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. .
JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (01) :116-123
[9]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P4932
[10]   Determination of Mn(II) ion by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) in different water samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 :699-707