Brain MR Image Restoration Using an Automatic Trilateral Filter With GPU-Based Acceleration

被引:13
作者
Chang, Herng-Hua [1 ]
Li, Cheng-Yuan [1 ]
Gallogly, Audrey Haihong [2 ]
机构
[1] Natl Taiwan Univ, Dept Engn Sci & Ocean Engn, Computat Biomed Engn Lab, Taipei 10617, Taiwan
[2] Univ Southern Calif, Keck Sch Med, Dept Radiat Oncol, Los Angeles, CA 90089 USA
关键词
Automation; GPU; image restoration; MRI; neural networks; SVM; texture feature; trilateral filter; RICIAN NOISE-REDUCTION; ANISOTROPIC DIFFUSION; SPATIAL-RESOLUTION; TEXTURAL FEATURES; EXTRACTION; ALGORITHM; VARIANCE; REMOVAL; MOTION; SNR;
D O I
10.1109/TBME.2017.2772853
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Noise reduction in brain magnetic resonance (MR) images has been a challenging and demanding task. This study develops a new trilateral filter that aims to achieve robust and efficient image restoration. Methods: Extended from the bilateral filter, the proposed algorithm contains one additional intensity similarity function, which compensates for the unique characteristics of noise in brain MR images. An entropy function adaptive to intensity variations is introduced to regulate the contributions of the weighting components. To hasten the computation, parallel computing based on the graphics processing unit (GPU) strategy is explored with emphasis on memory allocations and thread distributions. To automate the filtration, image texture feature analysis associated with machine learning is investigated. Among the 98 candidate features, the sequential forward floating selection scheme is employed to acquire the optimal texture features for regularization. Subsequently, a two-stage classifier that consists of support vector machines and artificial neural networks is established to predict the filter parameters for automation. Results: A speedup gain of 757 was reached to process an entire MR image volume of 256 x 256 x 256 pixels, which completed within 0.5 s. Automatic restoration results revealed high accuracy with an ensemble average relative error of 0.53 +/- 0.85% in terms of the peak signal-to-noise ratio. Conclusion: This self-regulating trilateral filter outperformed many state-of-the-art noise reduction methods both qualitatively and quantitatively. Significance: We believe that this new image restoration algorithm is of potential in many brain MR image processing applications that require expedition and automation.
引用
收藏
页码:400 / 413
页数:14
相关论文
共 62 条
  • [1] Aja-Fernández S, 2008, IEEE T MED IMAGING, V27, P1389, DOI 10.1109/TMI.2008.920609
  • [2] Noise and signal estimation in magnitude MRI and Rician distributed images:: A LMMSE approach
    Aja-Fernandez, Santiago
    Alberola-Lopez, Carlos
    Westin, Carl-Fredrik
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (08) : 1383 - 1398
  • [3] Noise estimation in single- and multiple-coil magnetic resonance data based on statistical models
    Aja-Fernandez, Santiago
    Tristan-Vega, Antonio
    Alberola-Lopez, Carlos
    [J]. MAGNETIC RESONANCE IMAGING, 2009, 27 (10) : 1397 - 1409
  • [4] [Anonymous], 1975, Comput. Graph. Image Process.
  • [5] Denoising of Contrast-Enhanced Ultrasound Cine Sequences Based on a Multiplicative Model
    Bar-Zion, Avinoam David
    Tremblay-Darveau, Charles
    Yin, Melissa
    Adam, Dan
    Foster, F. Stuart
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1969 - 1980
  • [6] AUTOMATIC DETECTION OF BRAIN CONTOURS IN MRI DATA SETS
    BRUMMER, ME
    MERSEREAU, RM
    EISNER, RL
    LEWINE, RRJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) : 153 - 166
  • [7] An Approach to Rapid Calculation of Temperature Change in Tissue Using Spatial Filters to Approximate Effects of Thermal Conduction
    Carluccio, Giuseppe
    Erricolo, Danilo
    Oh, Sukhoon
    Collins, Christopher M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1735 - 1741
  • [8] Restoration algorithm for image noise removal using double bilateral filtering
    Chang, Herng-Hua
    Chu, Woei-Chyn
    [J]. JOURNAL OF ELECTRONIC IMAGING, 2012, 21 (02)
  • [9] Chang HH, 2011, I S BIOMED IMAGING, P1823, DOI 10.1109/ISBI.2011.5872761
  • [10] Chaudhari A., 2016, DENOISING MAGNETIC R