Steady state magnetic sensors for ITER and beyond: Development and final design (invited)

被引:20
作者
Kocan, M. [1 ]
Duran, I. [2 ]
Entler, S. [2 ]
Vayakis, G. [1 ]
Agostinetti, P. [3 ]
Brombin, M. [3 ]
Carmona, J. M. [4 ]
Gambetta, G. [3 ]
Jirman, T. [5 ]
Marconato, N. [3 ]
Moreau, P. [6 ]
Peruzzo, S. [3 ]
Spuig, P. [6 ]
Walsh, M. [1 ]
机构
[1] ITER Org, Route Vinon Sur Verdon,CS 90 046, F-13067 St Paul Les Durance, France
[2] CAS, Inst Plasma Phys, Za Slovankou 3, Prague 18200, Czech Republic
[3] Consorzio RFX, Corso Stati Uniti 4, I-35137 Padua, Italy
[4] AVS, Pol Ind Sigma Xixil Kalea 2,Bajo Pabellon 10, Elgoibar 20870, Spain
[5] Imperial Coll London, Dept Phys, South Kensington Campus, London SW7 2AZ, England
[6] CEA, IRFM, F-13108 St Paul Les Durance, France
基金
欧盟地平线“2020”;
关键词
HALL SENSORS;
D O I
10.1063/1.5038871
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The measurements of the magnetic field in tokamaks such as ITER and DEMO will be challenging due to the long pulse duration, high neutron flux, and elevated temperatures. The long duration of the plasma pulse makes standard techniques, such as inductive coils, prone to errors. At the same time, the hostile environment, with repairs possible only on blanket exchange, if at all, requires a robust magnetic sensor. This contribution presents the final design of novel, steady-state, magnetic sensors for ITER. A poloidal array of 60 sensors mounted on the vacuum vessel outer shell contributes to the measurement of the plasma current, plasma-wall clearance, low-frequency MHD modes and will allow for crosscheck with the outer-vessel inductive coils. Each sensor hosts a pair of bismuth Hall probes, themselves an outcome of extensive R&D, including neutron irradiations (to 10(23) n/m(2)), temperature cycling tests (73-473 K) and tests at high magnetic field (to 12 T). A significant effort has been devoted to optimize the sensor housing by design and prototyping. The production version features an indium-filled cell for in situ recalibration of the onboard thermocouple, vital for the interpretation of the Hall sensor measurement.
引用
收藏
页数:6
相关论文
共 12 条
  • [1] MELTING CURVES AND HEAT OF FUSION OF INDIUM
    ANCSIN, J
    [J]. METROLOGIA, 1985, 21 (01) : 7 - 9
  • [2] ASHCROFT NW, 1976, SOLID STATE PHYS, pCH28
  • [3] High magnetic field test of bismuth Hall sensors for ITER steady state magnetic diagnostic
    Duran, I.
    Entler, S.
    Kohout, M.
    Kocan, M.
    Vayakis, G.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11)
  • [4] Development of Bismuth Hall sensors for ITER steady state magnetic diagnostics
    Duran, Ivan
    Entler, Slavomir
    Kocan, Martin
    Kohout, Michal
    Viererbl, Ladislav
    Musalek, Radomir
    Chraska, Tomas
    Vayakis, George
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 123 : 690 - 694
  • [5] High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
    Entler, S.
    Sebek, J.
    Duran, I.
    Vyborny, K.
    Grover, O.
    Kocan, M.
    Vayakis, G.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10)
  • [6] Recent Improvement of the Design of the ITER Steady-State Magnetic Sensors
    Entler, S.
    Kocan, M.
    Duran, I.
    Vayakis, G.
    Lucca, F.
    Vigano, F.
    Cantu, R.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) : 1276 - 1280
  • [7] Signal conditioning and processing for metallic Hall sensors
    Entler, S.
    Duran, I.
    Sladek, P.
    Vayakis, G.
    Kocan, M.
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 123 : 783 - 786
  • [8] Kyynarainen J., 2010, VTT REPORT MEMS MAGN
  • [9] Three-axis teslameter with integrated hall probe
    Popovic, Dragana R.
    Dimitrijevic, Sasa
    Blagojevic, Marjan
    Kejik, Pavel
    Schurig, Enrico
    Popovic, Radivoje S.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (04) : 1396 - 1402
  • [10] Popovic R. S., 2004, Hall Effect Devices, V2nd