Contrast media extravasation during dynamic CT: Detection with an extravasation detection accessory

被引:15
作者
Nelson, RC
Anderson, FA
Birnbaum, BA
Chezmar, JL
Glick, SN
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Univ Massachusetts, Ctr Med, Dept Surg, Worchester, MA USA
[3] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[4] Emory Univ Hosp, Dept Radiol, Atlanta, GA 30322 USA
[5] Hahneman Univ, Dept Radiol, Ctr Med, Philadelphia, PA USA
关键词
computed tomography (CT); contrast media; complications; interventional procedures;
D O I
10.1148/radiology.209.3.9844684
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To detect extravasation of contrast media during mechanical power injection at dynamic computed tomography x 8-cm pliable adhesive was applied to the skin over the intravenous cannula and connected to the power injector with a cable to monitor electrical skin impedance. If the rate of change or the slope of impedance over time indicated an extravasation event, the power injector was set into a pause mode, In animal and human studies, monitoring with the device was successful. Extravasation of ionic contrast agents decreased impedance and that of nonionic agents increased impedance.
引用
收藏
页码:837 / 843
页数:7
相关论文
共 33 条
[1]   IMPEDANCE PLETHYSMOGRAPHY IN THE DIAGNOSIS OF ARTERIAL AND VENOUS DISEASE [J].
ANDERSON, FA .
ANNALS OF BIOMEDICAL ENGINEERING, 1984, 12 (01) :79-102
[2]  
AYRESMITH G, 1982, J CAN ASSOC RADIOL, V33, P104
[3]   Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[4]   LOCAL COMPLICATIONS OF ASCENDING PHLEBOGRAPHY [J].
BERGE, T ;
BERGQVIST, D ;
EFSING, HO ;
HALLBOOK, T .
CLINICAL RADIOLOGY, 1978, 29 (06) :691-696
[5]   SEVERE EXTRAVASATION INJURY - AN AVOIDABLE IATROGENIC DISASTER [J].
BURD, DAR ;
SANTIS, G ;
MILWARD, TM .
BRITISH MEDICAL JOURNAL, 1985, 290 (6481) :1579-1580
[6]   IATROGENIC HAND INJURIES IN OUTPATIENTS [J].
BURRIS, JF ;
FAIRCHILD, PG .
SOUTHERN MEDICAL JOURNAL, 1986, 79 (12) :1515-1516
[7]   EXTRAVASATION OF NONIONIC RADIOLOGIC CONTRAST-MEDIA - EFFICACY OF CONSERVATIVE TREATMENT [J].
COHAN, RH ;
DUNNICK, NR ;
LEDER, RA ;
BAKER, ME .
RADIOLOGY, 1990, 176 (01) :65-67
[8]   EXTRAVASCULAR EXTRAVASATION OF RADIOGRAPHIC CONTRAST-MEDIA - EFFECTS OF CONVENTIONAL AND LOW-OSMOLAR AGENTS IN THE RAT THIGH [J].
COHAN, RH ;
LEDER, RA ;
BOLICK, D ;
HERZBERG, AJ ;
HEDLUND, LW ;
WHEELER, CT ;
HELMS, MJ ;
DUNNICK, NR .
INVESTIGATIVE RADIOLOGY, 1990, 25 (05) :504-510
[9]   Local reactions after injection of iodinated contrast material: Detection, management, and outcome [J].
Cohan, RH ;
Bullard, MA ;
Ellis, JH ;
Jan, SC ;
Francis, IR ;
Garner, WL ;
Dunnick, NR .
ACADEMIC RADIOLOGY, 1997, 4 (11) :711-718
[10]   Extravasation of radiographic contrast material: Recognition, prevention, and treatment [J].
Cohan, RH ;
Ellis, JH ;
Garner, WL .
RADIOLOGY, 1996, 200 (03) :593-604