Reliability of phase-velocity measurements of tibial bone

被引:20
作者
de Bruin, ED
Rozendal, RH
Stussi, E
机构
[1] Swiss Fed Inst Technol, Biomech Lab, CH-8952 Schlieren, Switzerland
[2] Vrije Univ Amsterdam, Fac Human Movement Sci, Amsterdam, Netherlands
来源
PHYSICAL THERAPY | 1998年 / 78卷 / 11期
关键词
bending stiffness; bone; flexural waves; measurement; reliability; spinal cord injury;
D O I
10.1093/ptj/78.11.1166
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. The Bone Stiffness Measurement Device-Swing is capable of measuring the propagation velocity of flexural waves in human tibial bone, which relates to bending stiffness. If the interrater and intrarater reliability of measurements obtained with the device are established, it can be used with confidence ill assessing changes in bone. The purposes of this study were to detect potential sources Of measurement error and to establish the interrater and intrarater reliability of measurements taken with the device. Subjects and Methods. In the first part of the study, a random-effects design was used to obtain phase-velocity measurements in subjects without known orthopedic or neurological impairments. The second part of the study consisted of possible applications of the device with mixed designs on subjects with spinal cord injuries. By means of generalizability theory, multiple sources of error (eg, occasion, clinician, repetition) were estimated. For the clinical trial, 17 persons with spinal cord injuries not older than 5 weeks were tested. Results. The standard error of measurement (SEM) for intrarater reliability measurements ranged fi-om 7.3 to 9.8 m.s(-1). The SEMs for interrater reliability measurements ranged from 5.7 to 9.5 m.s(-1). The SEMs for measurements obtained by a single clinician in a clinical population ranged from 11.9 to 39.7 m.s(-1). Conclusion and Discussion. The reproducibility of measurements obtained with the device is suitably high for the device to be used for evaluation in clinical and research settings.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 21 条
[1]  
Anderson V.L., 1974, DESIGN EXPT REALISTI, DOI DOI 10.1201/9781315141039
[2]  
BISCHOF H, 1993, THESIS U ZURICH
[3]   CLINICAL DETERMINATION OF BONE QUALITY - IS ULTRASOUND AN ANSWER [J].
BRANDENBURGER, GH ;
PIERCE ;
HEANEY ;
SCHNITZLER .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S151-S156
[4]  
CHENG S, 1994, THESIS U JYVASKYLA
[5]  
CRICK JE, 1984, MANUAL GENOVA GEN PU
[6]  
CRONBACH L J, 1972, P410
[7]   PHASE-VELOCITY MEASUREMENT OF FLEXURAL WAVES IN HUMAN TIBIA [J].
FAH, D ;
STUSSI, E .
JOURNAL OF BIOMECHANICS, 1988, 21 (11) :975-+
[8]   CONSIDERATIONS IN CHOICE OF INTEROBSERVER RELIABILITY ESTIMATES [J].
HARTMANN, DP .
JOURNAL OF APPLIED BEHAVIOR ANALYSIS, 1977, 10 (01) :103-116
[9]   Practical guide for the use of bone mineral measurements in the assessment of treatment of osteoporosis: A position paper of the European Foundation for Osteoporosis and Bone Disease [J].
Kanis, JA ;
Devogelaer, JP ;
Gennari, C .
OSTEOPOROSIS INTERNATIONAL, 1996, 6 (03) :256-261
[10]  
Martin RB., 1989, STRUCTURE FUNCTION A