Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging

被引:162
作者
Papavassiliu, T
Kühl, HP
Schröder, M
Süselbeck, T
Bondarenko, O
Böhm, CK
Beek, A
Hofman, MMB
van Rossum, AC
机构
[1] Univ Hosp Mannheim, Med Clin 1, D-68167 Mannheim, Germany
[2] Univ Hosp Mannheim, Dept Radiol, D-68167 Mannheim, Germany
[3] Vrije Univ Amsterdam, Ctr Med, Dept Cardiol, Amsterdam, Netherlands
关键词
D O I
10.1148/radiol.2353040601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP). MATERIALS AND METHODS: The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and endsystolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis. RESULTS: Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL +/- 11 [standard deviation] and 19 mL +/- 33, respectively; P <.001) and lower EFs (mean difference, -2% +/- 2; P <.001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, -21 g +/- 12; P <.001), All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume. CONCLUSION: Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use. ((c)) RSNA, 2005.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 20 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]  
ANDERSON RH, 1980, CARDIAC ANATOMY, P10
[3]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   VALUE OF ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR MASS IN PREDICTING CARDIOVASCULAR MORBID EVENTS IN HYPERTENSIVE MEN [J].
CASALE, PN ;
DEVEREUX, RB ;
MILNER, M ;
ZULLO, G ;
HARSHFIELD, GA ;
PICKERING, TG ;
LARAGH, JH .
ANNALS OF INTERNAL MEDICINE, 1986, 105 (02) :173-178
[6]  
FANG W, 2000, P 8 ANN M ISMRM DENV, P308
[7]  
IBRAHIM T, 1999, J CARDIOVASC MAGN R, V1, P319
[8]   RELATION OF LEFT-VENTRICULAR MASS AND GEOMETRY TO MORBIDITY AND MORTALITY IN UNCOMPLICATED ESSENTIAL-HYPERTENSION [J].
KOREN, MJ ;
DEVEREUX, RB ;
CASALE, PN ;
SAVAGE, DD ;
LARAGH, JH .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (05) :345-352
[9]   PROGNOSTIC IMPLICATIONS OF ECHOCARDIOGRAPHICALLY DETERMINED LEFT-VENTRICULAR MASS IN THE FRAMINGHAM-HEART-STUDY [J].
LEVY, D ;
GARRISON, RJ ;
SAVAGE, DD ;
KANNEL, WB ;
CASTELLI, WP .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (22) :1561-1566
[10]   Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging [J].
Lorenz, CH ;
Walker, ES ;
Morgan, VL ;
Klein, SS ;
Graham, TP .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :7-21