Validation of Monte Carlo 131I radiopharmaceutical dosimetry workflow using a 3D-printed anthropomorphic head and neck phantom

被引:5
作者
Adam, David P. [1 ]
Grudzinski, Joseph J. [2 ]
Bormett, Ian [3 ]
Cox, Benjamin L. [3 ]
Marsh, Ian R. [1 ]
Bradshaw, Tyler J. [2 ]
Harari, Paul M. [4 ]
Bednarz, Bryan P. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1005 WIMR,1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[3] Univ Wisconsin, Morgridge Inst Res, Madison, WI 53705 USA
[4] Univ Wisconsin, Dept Human Oncol, Madison, WI 53705 USA
关键词
3D printing; anthropomorphic phantom; radiopharmaceutical therapy dosimetry; 2ND PRIMARY HEAD; ATTENUATION COEFFICIENTS; DOSE REIRRADIATION; UNRESECTABLE HEAD; MEDICAL PROGRESS; CANCER; RECURRENT; RADIOTHERAPY; CHEMOTHERAPY; CISPLATIN;
D O I
10.1002/mp.15699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Approximately 50% of head and neck cancer (HNC) patients will experience loco-regional disease recurrence following initial courses of therapy. Retreatment with external beam radiotherapy (EBRT) is technically challenging and may be associated with a significant risk of irreversible damage to normal tissues. Radiopharmaceutical therapy (RPT) is a potential method to treat recurrent HNC in conjunction with EBRT. Phantoms are used to calibrate and add quantification to nuclear medicine images, and anthropomorphic phantoms can account for both the geometrical and material composition of the head and neck. In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom, and its characterization for the validation of a Monte Carlo, SPECT image-based, I-131 RPT dosimetry workflow. Methods 3D-printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three I-131 SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images using a GE Optima NM/CT 640 with a high energy general purpose collimator. The impact of collimator detector response (CDR) modeling and volume-based partial volume corrections (PVCs) upon the absorbed dose was calculated using an image-based, Geant4 Monte Carlo RPT dosimetry workflow and compared against a ground truth scenario. Finally, uncertainties were quantified in accordance with recent EANM guidelines. Results The 3D-printed anthropomorphic phantom was an accurate re-creation of patient anatomy including bone. The extrapolated Jaszczak recovery coefficients were greater than that of the 3D-printed insert (similar to 22.8 ml) for both the CDR and non-CDR cases (with CDR: 0.536 vs. 0.493, non-CDR: 0.445 vs. 0.426, respectively). Utilizing Jaszczak phantom PVCs, the absorbed dose was underpredicted by 0.7% and 4.9% without and with CDR, respectively. Utilizing anthropomorphic phantom recovery coefficient overpredicted the absorbed dose by 3% both with and without CDR. All dosimetry scenarios that incorporated PVC were within the calculated uncertainty of the activity. The uncertainties in the cumulative activity ranged from 23.6% to 106.4% for Jaszczak spheres ranging in volume from 0.5 to 16 ml. Conclusion The accuracy of Monte Carlo-based dosimetry for I-131 RPT in HNC was validated with an anthropomorphic phantom. In this study, it was found that Jaszczak-based PVCs were sufficient. Future applications of the phantom could involve 3D printing and characterizing patient-specific volumes for more personalized RPT dosimetry estimates.
引用
收藏
页码:5491 / 5503
页数:13
相关论文
共 60 条
[1]   Design and implementation of a prototype head and neck phantom for the performance evaluation of gamma imaging systems [J].
Alqahtani, Mohammed S. ;
Lees, John E. ;
Bugby, Sarah L. ;
Samara-Ratna, Piyal ;
Ng, Aik H. ;
Perkins, Alan C. .
EJNMMI PHYSICS, 2017, 4
[2]   Randomized Phase III Trial of Concurrent Accelerated Radiation Plus Cisplatin With or Without Cetuximab for Stage III to IV Head and Neck Carcinoma: RTOG 0522 [J].
Ang, K. Kian ;
Zhang, Qiang ;
Rosenthal, David I. ;
Nguyen-Tan, Phuc Felix ;
Sherman, Eric J. ;
Weber, Randal S. ;
Galvin, James M. ;
Bonner, James A. ;
Harris, Jonathan ;
El-Naggar, Adel K. ;
Gillison, Maura L. ;
Jordan, Richard C. ;
Konski, Andre A. ;
Thorstad, Wade L. ;
Trotti, Andy ;
Beitler, Jonathan J. ;
Garden, Adam S. ;
Spanos, William J. ;
Yom, Sue S. ;
Axelrod, Rita S. .
JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (27) :2940-+
[3]   Monte Carlo modeling of gamma cameras for I-131 imaging in targeted radiotherapy [J].
Autret, D ;
Bitar, A ;
Ferrer, L ;
Lisbona, A ;
Bardiés, M .
CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2005, 20 (01) :77-84
[4]   Development and Validation of RAPID: A Patient-Specific Monte Carlo Three-Dimensional Internal Dosimetry Platform [J].
Besemer, Abigail E. ;
Yang, You Ming ;
Grudzinski, Joseph J. ;
Hall, Lance T. ;
Bednarz, Bryan P. .
CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2018, 33 (04) :155-165
[5]   Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT [J].
Brown, Saxby ;
Bailey, Dale L. ;
Willowson, Kathy ;
Baldock, Clive .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (09) :1206-1212
[6]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[7]   PRACTICAL CONSIDERATIONS IN THE RE-IRRADIATION OF RECURRENT AND SECOND PRIMARY HEAD-AND-NECK CANCER: WHO, WHY, HOW, AND HOW MUCH? [J].
Chen, Allen M. ;
Phillips, Theodore L. ;
Lee, Nancy Y. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05) :1211-1219
[8]  
clinicaltrials.gov, 2020, CLR 131 COMBINED RAD
[9]   Head and neck cancer - An evolving treatment paradigm [J].
Cognetti, David M. ;
Weber, Randal S. ;
Lai, Stephen Y. .
CANCER, 2008, 113 (07) :1911-1932
[10]   Impact of conventional radiotherapy on health-related quality of life and critical functions of the head and neck [J].
Connor, Nadine P. ;
Cohen, Stacy B. ;
Kammer, Rachael E. ;
Sullivan, Paula A. ;
Brewer, Kathryn A. ;
Hong, Theodore S. ;
Chappell, Richard J. ;
Harari, Paul M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :1051-1062