Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results

被引:36
作者
Cooper, Lyndon F. [1 ]
Stanford, Clark [2 ]
Feine, Jocelyne [3 ]
McGuire, Michael
机构
[1] Univ Illinois, Coll Dent, Oral Biol, Chicago, IL USA
[2] Univ Illinois, Sch Dent, Chicago, IL USA
[3] McGill Univ, Fac Dent, Oral Hlth & Soc Res Unit, Montreal, PQ, Canada
关键词
AESTHETICALLY DEMANDING REGIONS; SINGLE-TOOTH RESTORATIONS; MEAN FOLLOW-UP; IMPLANT ABUTMENTS; CLINICAL-EVALUATION; TITANIUM ABUTMENTS; SOFT-TISSUE; ANTERIOR; CONNECTIONS; PERFORMANCE;
D O I
10.1016/j.prosdent.2015.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. Purpose. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. Material and methods. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (Cl; AstraTech OsseoSpeed), flat-to flat interface (Fl; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. Results. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. Conclusions. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2.4 years.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 27 条
  • [1] Altamimi AM, 2014, INT J ESTHET DENT, V9, P98
  • [2] Clinical Outcomes of Implant Abutments in the Anterior Region: A Systematic Review
    Bidra, Avinash S.
    Rungruanganunt, Patchanee
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2013, 25 (03) : 159 - 176
  • [3] Blamphin C N, 1990, Proc Inst Mech Eng H, V204, P129, DOI 10.1243/PIME_PROC_1990_204_242_02
  • [4] EFFECT OF PLATFORM CONNECTION AND ABUTMENT MATERIAL ON STRESS DISTRIBUTION IN SINGLE ANTERIOR IMPLANT-SUPPORTED RESTORATIONS: A NONLINEAR 3-DIMENSIONAL FINITE ELEMENT ANALYSIS
    Carvalho, Marco Aurelio
    Sotto-Maior, Bruno Salles
    Cury, Altair Antoninha Del Bel
    Pessanha Henriques, Guilherme Elias
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (05) : 1096 - 1102
  • [5] Low-temperature degradation of Zirconia and implications for biomedical implants
    Chevalier, Jerome
    Gremillard, Laurent
    Deville, Sylvain
    [J]. ANNUAL REVIEW OF MATERIALS RESEARCH, 2007, 37 (1-32) : 1 - 32
  • [6] A Multicenter Randomized Comparative Trial of Implants with Different Abutment Interfaces to Replace Anterior Maxillary Single Teeth
    Cooper, Lyndon F.
    Reside, Glenn
    Stanford, Clark
    Barwacz, Chris
    Feine, Jocelyne
    Nader, Samer Abi
    Scheyer, E. Todd
    McGuire, Michael
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) : 622 - 632
  • [7] Influence of abutment material and luting cements color on the final color of all ceramics
    Dede, Dogu Omur
    Armaganci, Arzu
    Ceylan, Gozlem
    Cankaya, Soner
    Celik, Ersan
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (06) : 1570 - 1578
  • [8] PRACTICE-BASED CLINICAL EVALUATION OF CERAMIC SINGLE CROWNS AFTER AT LEAST FIVE YEARS
    Dhima, Matilda
    Paulusova, Vladimira
    Carr, Alan B.
    Rieck, Kevin L.
    Lohse, Christine
    Salinas, Thomas J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (02) : 124 - 130
  • [9] Clinical Evaluation of 860 Anterior and Posterior Lithium Disilicate Restorations: Retrospective Study with a Mean Follow-up of 3 Years and a Maximum Observational Period of 6 Years
    Fabbri, Giacomo
    Zarone, Fernando
    Dellificorelli, Gianluca
    Cannistraro, Giorgio
    De Lorenzi, Marco
    Mosca, Alberto
    Sorrentino, Roberto
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (02) : 165 - 177
  • [10] Evaluation of soft tissue around single-tooth implant crowns:: the pink esthetic score
    Fürhauser, R
    Florescu, D
    Benesch, T
    Haas, R
    Mailath, G
    Watzek, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (06) : 639 - 644