A review of electrical impedance tomography in lung applications: Theory and algorithms for absolute images

被引:74
|
作者
Martins, Thiago de Castro [1 ]
Sato, Andre Kubagawa [1 ]
de Moura, Fernando Silva [2 ]
Leon Bueno de Camargo, Erick Dario [2 ]
Silva, Olavo Luppi [2 ]
Rattis Santos, Talles Batista [3 ]
Zhao, Zhanqi [4 ,5 ]
Moeller, Knut [4 ]
Passos Amato, Marcelo Brito [6 ]
Mueller, Jennifer L. [7 ,8 ]
Lima, Raul Gonzalez [3 ]
Guerra Tsuzuki, Marcos de Sales [1 ]
机构
[1] Univ Sao Paulo, Escola Politecn, Computat Geometry Lab, Sao Paulo, SP, Brazil
[2] Univ Fed ABC, Ctr Engn Modeling & Appl Social Sci, Santo Andre, SP, Brazil
[3] Univ Sao Paulo, Escola Politecn, Dept Mech Engn, Sao Paulo, SP, Brazil
[4] Furtwangen Univ, Inst Tech Med, Furtwangen, Germany
[5] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Shaanxi, Peoples R China
[6] Univ Sao Paulo, Hosp Clin, Div Pulm, Resp Intens Care Unit, Sao Paulo, SP, Brazil
[7] Colorado State Univ, Dept Math, Ft Collins, CO 80523 USA
[8] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
基金
巴西圣保罗研究基金会;
关键词
Electrical impedance tomography; Anatomical atlas; Bayesian inference; Massive parallel computing; Approximation error; ARDS; Lung diseases; D-BAR METHOD; END-EXPIRATORY PRESSURE; RESPIRATORY-DISTRESS-SYNDROME; ARTIFICIAL BOUNDARY-CONDITIONS; OPTIMAL CURRENT PATTERNS; ELECTRODE MODELS; SPATIAL PRIOR; RECONSTRUCTION ALGORITHM; DIELECTRIC-PROPERTIES; REGIONAL VENTILATION;
D O I
10.1016/j.arcontrol.2019.05.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) is under fast development. The present paper is a review of some procedures that have contributed to improve spatial resolution and material properties accuracy, admitivity or impeditivity accuracy. A review of EIT medical applications is presented and they were classified into three broad categories: ARDS patients, obstructive lung diseases and perioperative patients. The use of absolute EIT image may enable the assessment of absolute lung volume, which may significantly improve clinical acceptance of EIT. The Control Theory, State Observers more specifically, have a developed theory that can be used for designing and operating EIT devices. Electrode placement, current injection strategy and electrode electric potential measurements strategy should maximize the number of observable and controllable directions of the state vector space. A non-linear stochastic state observer, the Unscented Kalman Filter, is used directly for reconstructing absolute EIT images. Historically, difference images were explored first since they are more stable in the presence of modelling errors. Absolute images require more detailed models of contact impedance, stray capacitance and properly refined finite element mesh, where the electric potential gradient is high. Parallelization of the forward program computation is necessary since the solution of the inverse problem often requires frequent solutions of the forward problem. Several reconstruction algorithms benefit from the Bayesian inverse problem approach and the concept of prior information. Anatomic and physiological information are used to form the prior information. An already tested methodology is presented to build the prior probability density function using an ensemble of CT scans and in vivo impedance measurements. Eight absolute EIT image algorithms are presented. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:442 / 471
页数:30
相关论文
共 50 条
  • [31] Electrical impedance tomography in acute lung injury
    Riera, J.
    Riu, P. J.
    Casan, P.
    Masclans, J. R.
    MEDICINA INTENSIVA, 2011, 35 (08) : 509 - 517
  • [32] Data errors and reconstruction algorithms in electrical impedance tomography
    Breckon, W.R.
    Pidcock, M.K.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 105 - 109
  • [33] COMPARING RECONSTRUCTION ALGORITHMS FOR ELECTRICAL IMPEDANCE TOMOGRAPHY.
    Yorkey, Thomas J.
    Webster, John G.
    Tompkins, Willis J.
    IEEE Transactions on Biomedical Engineering, 1987, BME-34 (11) : 843 - 852
  • [34] COMPARING RECONSTRUCTION ALGORITHMS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    YORKEY, TJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (11) : 843 - 852
  • [35] Application of New Algorithms of Electrical Impedance Tomography in Biomedicine
    Kriz, T.
    Dedkova, J.
    Gescheidtova, E.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 1737 - 1740
  • [36] Electrical Impedance Tomography Methods and Algorithms Processed with a GPU
    Dusek, J.
    Hladky, D.
    Mikulka, J.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 1710 - 1714
  • [37] Comparison of total variation algorithms for electrical impedance tomography
    Zhou, Zhou
    dos Santos, Gustavo Sato
    Dowrick, Thomas
    Avery, James
    Sun, Zhaolin
    Xu, Hui
    Holder, David S.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1193 - 1209
  • [40] Theory and development of electrical impedance tomography technology
    Cheng, Jikuan
    Sun, Jinping
    Du, Yan
    Liu, Zhongkan
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 1998, 24 (02): : 137 - 140