Single-shot T2 mapping via multi-echo-train multiple overlapping-echo detachment planar imaging and multitask deep learning

被引:8
|
作者
Ouyang, Binyu [1 ]
Yang, Qizhi [1 ]
Wang, Xiaoyin [2 ]
He, Hongjian [2 ]
Ma, Lingceng [1 ]
Yang, Qinqin [1 ]
Zhou, Zihan [2 ]
Cai, Shuhui [1 ]
Chen, Zhong [1 ]
Wu, Zhigang [3 ]
Zhong, Jianhui [2 ,4 ]
Cai, Congbo [1 ]
机构
[1] Xiamen Univ, Dept Elect Sci, Fujian Prov Key Lab Plasma & Magnet Resonance, Xiamen 361005, Fujian, Peoples R China
[2] Zhejiang Univ, Coll Biomed Engn & Instrumental Sci, Ctr Brain Imaging Sci & Technol, Hangzhou 310058, Zhejiang, Peoples R China
[3] Philips Healthcare, MSC Clin & Tech Solut, Shenzhen 518005, Guangdong, Peoples R China
[4] Univ Rochester, Dept Imaging Sci, Rochester, NY 14642 USA
基金
中国国家自然科学基金;
关键词
multitask deep learning; multiple overlapping-echo detachment; parametric map reconstruction; quantitative magnetic resonance imaging; T-2; mapping; CONVOLUTIONAL NEURAL-NETWORKS; T2; RELAXATION-TIME; RECONSTRUCTION; MRI; RF; ACQUISITION; ACCURATE; PHANTOMS;
D O I
10.1002/mp.15820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Quantitative magnetic resonance imaging provides robust biomarkers in clinics. Nevertheless, the lengthy scan time reduces imaging throughput and increases the susceptibility of imaging results to motion. In this context, a single-shot T-2 mapping method based on multiple overlapping-echo detachment (MOLED) planar imaging was presented, but the relatively small echo time range limits its accuracy, especially in tissues with large T-2. Purpose In this work we proposed a novel single-shot method, Multi-Echo-Train Multiple OverLapping-Echo Detachment (METMOLED) planar imaging, to accommodate a large range of T-2 quantification without additional measurements to rectify signal degeneration arisen from refocusing pulse imperfection. Methods Multiple echo-train techniques were integrated into the MOLED sequence to capture larger TE information. Maps of T-2, B-1, and spin density were reconstructed synchronously from acquired METMOLED data via multitask deep learning. A typical U-Net was trained with 3000/600 synthetic data with geometric/brain patterns to learn the mapping relationship between METMOLED signals and quantitative maps. The refocusing pulse imperfection was settled through the inherent information of METMOLED data and auxiliary tasks. Results Experimental results on the digital brain (structural similarity (SSIM) index = 0.975/0.991/0.988 for MOLED/METMOLED-2/METMOLED-3, hyphenated number denotes the number of echo-trains), physical phantom (the slope of linear fitting with reference T-2 map = 1.047/1.017/1.006 for MOLED/METMOLED-2/METMOLED-3), and human brain (Pearson's correlation coefficient (PCC) = 0.9581/0.9760/0.9900 for MOLED/METMOLED-2/METMOLED-3) demonstrated that the METMOLED improved the quantitative accuracy and the tissue details in contrast to the MOLED. These improvements were more pronounced in tissues with large T-2 and in application scenarios with high temporal resolution (PCC = 0.8692/0.9465/0.9743 for MOLED/METMOLED-2/METMOLED-3). Moreover, the METMOLED could rectify the signal deviations induced by the non-ideal slice profiles of refocusing pulses without additional measurements. A preliminary measurement also demonstrated that the METMOLED is highly repeatable (mean coefficient of variation (CV) = 1.65%). Conclusions METMOLED breaks the restriction of echo-train length to TE and implements unbiased T-2 estimates in an extensive range. Furthermore, it corrects the effect of refocusing pulse inaccuracy without additional measurements or signal post-processing, thus retaining its single-shot characteristic. This technique would be beneficial for accurate T-2 quantification.
引用
收藏
页码:7095 / 7107
页数:13
相关论文
共 44 条
  • [21] Optimized protocol for high resolution functional magnetic resonance imaging at 3 T using single-shot echo planar imaging
    Domsch, Sebastian
    Zapp, Jascha
    Schad, Lothar R.
    Nees, Frauke
    Hill, Holger
    Hermann, Derik
    Mann, Karl
    Vollstaedt-Klein, Sabine
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 239 : 170 - 182
  • [22] T2 mapping and readout segmentation of long variable echo-train diffusion-weighted imaging for the differentiation of parotid gland tumors
    Wen, Baohong
    Jing, Zhu
    Zhang, Zanxia
    Kun, Fu
    Liang, Liu
    Gao, Eryuan
    Yong, Zhang
    Fei, Han
    Cheng, Jingliang
    Zhu, Jinxia
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [23] Simultaneous pure T2 and varying T2′ -weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
    Wang, Fuyixue
    Dong, Zijing
    Wald, Lawrence L.
    Polimeni, Jonathan R.
    Setsompop, Kawin
    NEUROIMAGE, 2021, 245
  • [24] Single-Shot T1 Mapping Using Simultaneous Acquisitions of Spin- and Stimulated-Echo-Planar Imaging (2D ss-SESTEPI)
    Shi, Xianfeng
    Kim, Seong-Eun
    Jeong, Eun-Kee
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 734 - 742
  • [25] Advanced diffusion weighted imaging of the prostate: Comparison of readout-segmented multi-shot, parallel-transmit and single-shot echo-planar imaging
    Klingebiel, M.
    Ullrich, T.
    Quentin, M.
    Bonekamp, D.
    Aissa, J.
    Mally, D.
    Arsov, C.
    Albers, P.
    Antoch, G.
    Schimmoeller, L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [26] Feasibility Study of 3-T DWI of the Prostate: Readout-Segmented Versus Single-Shot Echo-Planar Imaging
    Li, Liang
    Wang, Liang
    Deng, Ming
    Liu, Hui
    Cai, Jie
    Sah, Vivek Kumar
    Liu, Jihong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 70 - 76
  • [27] Impact of Deep Learning Reconstruction Combined With a Sharpening Filter on Single-Shot Fast Spin-Echo T2-Weighted Magnetic Resonance Imaging of the Uterus
    Tsuboyama, Takahiro
    Onishi, Hiromitsu
    Nakamoto, Atsushi
    Ogawa, Kazuya
    Koyama, Yoshihiro
    Tarewaki, Hiroyuki
    Tomiyama, Noriyuki
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 379 - 386
  • [28] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [29] Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging
    Coenegrachts, Kenneth
    Matos, Celso
    ter Beek, Leon
    Metens, Thierry
    Haspeslagh, Marc
    Bipat, Shandra
    Stoker, Jaap
    Rigauts, Hans
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 432 - 439
  • [30] High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T
    Ma, Chao
    Li, Yan-jun
    Pan, Chun-shu
    Wang, He
    Wang, Jian
    Chen, Shi-yue
    Lu, Jian-ping
    MAGNETIC RESONANCE IMAGING, 2014, 32 (02) : 125 - 131