Single-shot T2 mapping via multi-echo-train multiple overlapping-echo detachment planar imaging and multitask deep learning

被引:8
|
作者
Ouyang, Binyu [1 ]
Yang, Qizhi [1 ]
Wang, Xiaoyin [2 ]
He, Hongjian [2 ]
Ma, Lingceng [1 ]
Yang, Qinqin [1 ]
Zhou, Zihan [2 ]
Cai, Shuhui [1 ]
Chen, Zhong [1 ]
Wu, Zhigang [3 ]
Zhong, Jianhui [2 ,4 ]
Cai, Congbo [1 ]
机构
[1] Xiamen Univ, Dept Elect Sci, Fujian Prov Key Lab Plasma & Magnet Resonance, Xiamen 361005, Fujian, Peoples R China
[2] Zhejiang Univ, Coll Biomed Engn & Instrumental Sci, Ctr Brain Imaging Sci & Technol, Hangzhou 310058, Zhejiang, Peoples R China
[3] Philips Healthcare, MSC Clin & Tech Solut, Shenzhen 518005, Guangdong, Peoples R China
[4] Univ Rochester, Dept Imaging Sci, Rochester, NY 14642 USA
基金
中国国家自然科学基金;
关键词
multitask deep learning; multiple overlapping-echo detachment; parametric map reconstruction; quantitative magnetic resonance imaging; T-2; mapping; CONVOLUTIONAL NEURAL-NETWORKS; T2; RELAXATION-TIME; RECONSTRUCTION; MRI; RF; ACQUISITION; ACCURATE; PHANTOMS;
D O I
10.1002/mp.15820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Quantitative magnetic resonance imaging provides robust biomarkers in clinics. Nevertheless, the lengthy scan time reduces imaging throughput and increases the susceptibility of imaging results to motion. In this context, a single-shot T-2 mapping method based on multiple overlapping-echo detachment (MOLED) planar imaging was presented, but the relatively small echo time range limits its accuracy, especially in tissues with large T-2. Purpose In this work we proposed a novel single-shot method, Multi-Echo-Train Multiple OverLapping-Echo Detachment (METMOLED) planar imaging, to accommodate a large range of T-2 quantification without additional measurements to rectify signal degeneration arisen from refocusing pulse imperfection. Methods Multiple echo-train techniques were integrated into the MOLED sequence to capture larger TE information. Maps of T-2, B-1, and spin density were reconstructed synchronously from acquired METMOLED data via multitask deep learning. A typical U-Net was trained with 3000/600 synthetic data with geometric/brain patterns to learn the mapping relationship between METMOLED signals and quantitative maps. The refocusing pulse imperfection was settled through the inherent information of METMOLED data and auxiliary tasks. Results Experimental results on the digital brain (structural similarity (SSIM) index = 0.975/0.991/0.988 for MOLED/METMOLED-2/METMOLED-3, hyphenated number denotes the number of echo-trains), physical phantom (the slope of linear fitting with reference T-2 map = 1.047/1.017/1.006 for MOLED/METMOLED-2/METMOLED-3), and human brain (Pearson's correlation coefficient (PCC) = 0.9581/0.9760/0.9900 for MOLED/METMOLED-2/METMOLED-3) demonstrated that the METMOLED improved the quantitative accuracy and the tissue details in contrast to the MOLED. These improvements were more pronounced in tissues with large T-2 and in application scenarios with high temporal resolution (PCC = 0.8692/0.9465/0.9743 for MOLED/METMOLED-2/METMOLED-3). Moreover, the METMOLED could rectify the signal deviations induced by the non-ideal slice profiles of refocusing pulses without additional measurements. A preliminary measurement also demonstrated that the METMOLED is highly repeatable (mean coefficient of variation (CV) = 1.65%). Conclusions METMOLED breaks the restriction of echo-train length to TE and implements unbiased T-2 estimates in an extensive range. Furthermore, it corrects the effect of refocusing pulse inaccuracy without additional measurements or signal post-processing, thus retaining its single-shot characteristic. This technique would be beneficial for accurate T-2 quantification.
引用
收藏
页码:7095 / 7107
页数:13
相关论文
共 44 条
  • [1] Single-Shot T2 Mapping Through OverLapping-Echo Detachment (OLED) Planar Imaging
    Cai, Congbo
    Zeng, Yiqing
    Zhuang, Yuchuan
    Cai, Shuhui
    Chen, Lin
    Ding, Xinghao
    Bao, Lijun
    Zhong, Jianhui
    Chen, Zhong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (10) : 2450 - 2461
  • [2] Robust Single-Shot T2 Mapping via Multiple Overlapping-Echo Acquisition and Deep Neural Network
    Zhang, Jun
    Wu, Jian
    Chen, Shaojian
    Zhang, Zhiyong
    Cai, Shuhui
    Cai, Congbo
    Chen, Zhong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (08) : 1801 - 1811
  • [3] Single-shot T2 mapping using overlapping-echo detachment planar imaging and a deep convolutional neural network
    Cai, Congbo
    Wang, Chao
    Zeng, Yiqing
    Cai, Shuhui
    Liang, Dong
    Wu, Yawen
    Chen, Zhong
    Ding, Xinghao
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2202 - 2214
  • [4] A simultaneous multi-slice T2 mapping framework based on overlapping-echo detachment planar imaging and deep learning reconstruction
    Li, Simin
    Wu, Jian
    Ma, Lingceng
    Cai, Shuhui
    Cai, Congbo
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2239 - 2253
  • [5] Free-breathing and instantaneous abdominal T2 mapping via single-shot multiple overlapping-echo acquisition and deep learning reconstruction
    Lin, Xi
    Dai, Lixing
    Yang, Qinqin
    Yang, Qizhi
    He, Hongjian
    Ma, Lingceng
    Liu, Jingjing
    Cheng, Jingliang
    Cai, Congbo
    Bao, Jianfeng
    Chen, Zhong
    Cai, Shuhui
    Zhong, Jianhui
    EUROPEAN RADIOLOGY, 2023, 33 (07) : 4938 - 4948
  • [6] Single-shot multi-parametric mapping based on multiple overlapping-echo detachment (MOLED) imaging
    Ma, Lingceng
    Wu, Jian
    Yang, Qinqin
    Zhou, Zihan
    He, Hongjian
    Bao, Jianfeng
    Bao, Lijun
    Wang, Xiaoyin
    Zhang, Pujie
    Zhong, Jianhui
    Cai, Congbo
    Cai, Shuhui
    Chen, Zhong
    NEUROIMAGE, 2022, 263
  • [7] Sub-second whole brain T2 mapping via multiband SENSE multiple overlapping-echo detachment imaging and deep learning
    Li, Simin
    Kang, Taishan
    Wu, Jian
    Chen, Weikun
    Lin, Qing
    Wu, Zhigang
    Wang, Jiazheng
    Cai, Congbo
    Cai, Shuhui
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19)
  • [8] Single-shot T2 mapping via multi-slice information sharing based on switching modulation patterns multiple overlapping-echo detachment imaging
    Dai, Chenyang
    Yang, Qinqin
    Zhou, Jianjun
    Zhu, Liuhong
    Lin, Liangjie
    Wang, Jiazheng
    Cai, Congbo
    Cai, Shuhui
    MEDICAL PHYSICS, 2025,
  • [9] Free-breathing and instantaneous abdominal T2 mapping via single-shot multiple overlapping-echo acquisition and deep learning reconstruction
    Xi Lin
    Lixing Dai
    Qinqin Yang
    Qizhi Yang
    Hongjian He
    Lingceng Ma
    Jingjing Liu
    Jingliang Cheng
    Congbo Cai
    Jianfeng Bao
    Zhong Chen
    Shuhui Cai
    Jianhui Zhong
    European Radiology, 2023, 33 : 4938 - 4948
  • [10] High Efficient Reconstruction of Single-Shot Magnetic Resonance T2 Mapping Through Overlapping Echo Detachment and DenseNet
    Wang, Chao
    Wu, Yawen
    Ding, Xinghao
    Huang, Yue
    Cai, Congbo
    NEURAL INFORMATION PROCESSING (ICONIP 2018), PT VI, 2018, 11306 : 408 - 418