A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery

被引:161
|
作者
Kim, Ho-Joong [1 ,2 ,3 ]
Jung, Whan-Ik [1 ,2 ,3 ]
Chang, Bong-Soon [4 ,5 ]
Lee, Choon-Ki [4 ,5 ]
Kang, Kyoung-Tak [6 ]
Yeom, Jin S. [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Med, Spine Ctr, 166 Gumiro, Sungnam 463707, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, 166 Gumiro, Sungnam 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, 166 Gumiro, Sungnam 463707, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[5] Seoul Natl Univ Hosp, Seoul, South Korea
[6] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
关键词
free-hand technique; posterior lumbar interbody fusion; proximal facet joint violation; randomized controlled trial; robot-assisted pedicle screw fixation; FACET JOINT VIOLATIONS; LUMBAR SPINE; PLACEMENT; ACCURACY; FUSION; ECONOMICS; ADJACENT; STENOSIS;
D O I
10.1002/rcs.1779
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThe purpose of this study was to compare the accuracy and safety of an instrumented posterior lumbar interbody fusion (PLIF) using a robot-assisted minimally invasive (Robot-PLIF) or a conventional open approach (Freehand-PLIF). MethodsPatients undergoing an instrumented PLIF were randomly assigned to be treated using a Robot-PLIF (37 patients) and a Freehand-PLIF (41 patients). ResultsFor intrapedicular accuracy, there was no significant difference between the groups (P = 0.534). For proximal facet joint accuracy, none of the 74 screws in the Robot-PLIF group violated the proximal facet joint, while 13 of 82 in the Freehand-PLIF group violated the proximal facet joint (P < 0.001). The average distance of the screws from the facets was 5.2 2.1 mm and 2.7 +/- 1.6 mm in the Robot-PLIF and Freehand-PLIF groups, respectively (P < 0.001). ConclusionRobotic-assisted pedicle screw placement was associated with fewer proximal facet joint violations and better convergence orientations.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Robot-assisted percutaneous pars-pedicle screw fixation for treating Hangman's fracture
    Zhao, Jingwei
    Liu, Yajun
    Zhang, Qi
    Fan, Mingxing
    Han, Xiaoguang
    He, Da
    Liu, Bo
    Tian, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [32] Robot-assisted vs freehand cannulated screw placement in femoral neck fractures surgery A systematic review and meta-analysis
    Zheng, Yongshun
    Yang, Jiazhao
    Zhang, Fan
    Lu, Jinsen
    Qian, Yeben
    MEDICINE, 2021, 100 (20) : E25926
  • [33] Impact of landmark crater creation on improving accuracy of pedicle screw insertion in robot-assisted scoliosis surgery
    Oba, Hiroki
    Ikegami, Shota
    Uehara, Masashi
    Hatakenaka, Terue
    Miyaoka, Yoshinari
    Kurogochi, Daisuke
    Fukuzawa, Takuma
    Sasao, Shinji
    Shigenobu, Keisuke
    Makiyama, Fumiaki
    Koseki, Michihiko
    Neo, Masashi
    Takahashi, Jun
    EUROPEAN SPINE JOURNAL, 2024, 33 (12) : 4730 - 4739
  • [34] Sensorless Based Haptic Feedback Integration In Robot-assisted Pedicle Screw Insertion For Lumbar Spine Surgery: A preliminary cadaveric study
    Nakdhamabhorn, Sakol
    Pillai, Branesh M.
    Chotivichit, Areesak
    Suthakorn, Jackrit
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2024, 24 : 420 - 433
  • [35] Robot-assisted pedicle screw insertion versus navigation-based and freehand techniques for posterior spinal fusion in scoliosis: a systematic review and meta-analysis
    Al-Naseem, Abdulrahman O.
    Al-Muhannadi, Abdullah
    Ramadhan, Mohammad
    Alfadhli, Alwaleed
    Marwan, Yousef
    Shafafy, Roozbeh
    Abd-El-Barr, Muhammad M.
    SPINE DEFORMITY, 2024, 12 (05) : 1203 - 1215
  • [36] Current status and prospects of robot-assisted spine surgery
    Zhang, Qi
    He, Da
    Fang, Yanming
    Fan, Mingxing
    EXPERT REVIEW OF MEDICAL DEVICES, 2025, 22 (03) : 187 - 192
  • [37] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Hao Liu
    Weikai Chen
    Zongyi Wang
    Jun Lin
    Bin Meng
    Huilin Yang
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 2273 - 2281
  • [38] A Comparison Between Robotic-Assisted Scaphoid Screw Fixation and a Freehand Technique for Acute Scaphoid Fracture: A Randomized, Controlled Trial
    Guo, Yang
    Ma, Wei
    Zlotolow, Dan
    Wang, Chao
    Tong, Dedi
    Liu, Kun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (12): : 1172 - 1179
  • [39] A preliminary study of a novel robotic system for pedicle screw fixation: A randomised controlled trial
    Li, Zongze
    Chen, Jianting
    Zhu, Qing-An
    Zheng, Shaoli
    Zhong, Zhaoming
    Yang, Jincheng
    Yang, Dehong
    Jiang, Hui
    Jiang, Wangsheng
    Zhu, Yongjian
    Sun, Donghui
    Huang, Wei
    Chen, Jiarui
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 20 : 73 - 79
  • [40] A novel fluoroscopy-based robot system for pedicle screw fixation surgery
    Luo, Yanzhong
    Li, Zhuofu
    Jiang, Shuai
    Hu, Lei
    Liu, Wenyong
    Li, Weishi
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (06) : 1 - 8