Biomechanical Evaluation of Proximal Hamstring Repair: All-Suture Anchor Versus Titanium Suture Anchor

被引:5
|
作者
Otto, Alexander [1 ,2 ,3 ]
DiCosmo, Alyssa M. [1 ]
Baldino, Joshua B. [1 ]
Mehl, Julian [1 ,2 ]
Obopilwe, Elifho [1 ]
Cote, Mark P. [1 ]
Imhoff, Andreas B. [1 ,2 ]
Beitzel, Knut [1 ,2 ,4 ]
Mazzocca, Augustus D. [1 ,2 ]
Coyner, Katherine [1 ,2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[2] Tech Univ Munich, Dept Orthopaed Sports Med, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
[4] ATOS Orthoparc Klin Koln, Cologne, Germany
关键词
proximal hamstring avulsion; hip; all-suture anchor; titanium suture anchor; biomechanics; proximal hamstring repair; SURGICAL REPAIR; AVULSION INJURIES; TENDON RUPTURES; OUTCOMES; SPORTS; ORIGIN; TAPE;
D O I
10.1177/2325967119892925
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal hamstring avulsions are severe tendon injuries and are commonly sports-related. Open and endoscopic techniques as well as different anchor configurations have already been described for proximal hamstring repair. Novel all-suture anchors have been developed to provide decreased bone loss during placement and reduced occupied bone volume when compared with titanium suture anchors. Hypothesis: Complete proximal hamstring avulsions repaired with all-suture anchors will demonstrate equal load to failure and comparable displacement under cyclic loading when compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Complete proximal hamstring avulsions were created in 18 paired cadaveric specimens (mean +/- SD age, 63.0 +/- 10.4 years). Either all-suture anchors or titanium suture anchors were used for repair. Cyclic loading from 10 to 125 N at 1 Hz was performed for 1500 cycles with a material testing machine. Displacement was assessed along anterior and posterior aspects of the tendon repair with optical tracking. Specimens were loaded to failure at a rate of 120 mm/min. Displacement, load to failure, and repair construct stiffness were compared between matched pairs with the Wilcoxon signed-rank test. Correlations were determined by Spearman rho analysis. Results: The all-suture anchors showed significantly higher load-to-failure values when compared with the titanium anchor repairs (799.64 +/- 257.1 vs 573.27 +/- 89.9 N; P = .008). There was no significant difference in displacement between all-suture anchors and titanium suture anchors at the anterior aspect (6.60 +/- 2.2 vs 5.49 +/- 1.1 mm; P = .26) or posterior aspect (5.87 +/- 2.08 vs 5.23 +/- 1.37 mm; P = .678) of the repaired hamstring tendons. Conclusion: All-suture anchors demonstrated similar displacement and superior load to failure when compared with titanium suture anchors.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Use of an All-Suture Anchor for Re-Creation of the Anterior Talofibular Ligament: A Case Report
    Piraino, Jason A.
    Busch, Elliot L.
    Sansosti, Laura E.
    Pettineo, Steven J.
    Creech, Corine
    JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (01) : 126 - 129
  • [42] Biomechanical Analysis of an Arthroscopic Brostrom Ankle Ligament Repair and a Suture Anchor-Augmented Repair
    Giza, Eric
    Whitlow, Scott R.
    Williams, Brady T.
    Acevedo, Jorge I.
    Mangone, Peter G.
    Haytmanek, C. Thomas
    Curry, Eugene E.
    Turnbull, Travis Lee
    LaPrade, Robert F.
    Wijdicks, Coen A.
    Clanton, Thomas O.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (07) : 836 - 841
  • [43] Biomechanical comparison of 3 suture anchor configurations for repair of type II SLAP lesions
    Domb, Benjamin G.
    Ehteshami, John R.
    Shindle, Michael K.
    Gulotta, Lawrence
    Zoghi-Moghadam, Mohamad
    MacGillivray, John D.
    Altchek, David W.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (02) : 135 - 140
  • [44] Superior load-to-failure in an all-suture anchor system for all-inside meniscal repair compared to a PEEK-cage anchor system in an experimental cadaveric test setting
    Pichler, Lorenz
    Kiss, Gyula
    Sator, Thomas
    Schuller, Andrea
    Kandathil, Sam A.
    Hofbauer, Marcus
    Koch, Thomas
    Hirtler, Lena
    Tiefenboeck, Thomas
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [45] Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons
    Petri, M.
    Dratzidis, A.
    Brand, S.
    Calliess, T.
    Hurschler, C.
    Krettek, C.
    Jagodzinski, M.
    Ettinger, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (04) : 1039 - 1045
  • [46] Suture anchor versus screw fixation for greater tuberosity fractures of the humerusua biomechanical study
    Lin, Cheng-Li
    Hong, Chih-Kai
    Jou, I-Ming
    Lin, Chii-Jeng
    Su, Fong-Chin
    Su, Wei-Ren
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (03) : 423 - 428
  • [47] Evaluation of a New Knotless Suture Anchor Repair in Acute Achilles Tendon Ruptures: A Biomechanical Comparison of Three Techniques
    Cottom, James M.
    Baker, Joseph S.
    Richardson, Phillip E.
    Maker, Jared M.
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (03) : 423 - 427
  • [48] Knotless Suture Anchor With Suture Tape Quadriceps Tendon Repair Is Biomechanically Superior to Transosseous and Traditional Suture Anchor-Based Repairs in a Cadaveric Model
    Kindya, Michael C.
    Konicek, John
    Rizzi, Angelo
    Komatsu, David E.
    Paci, James M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (01) : 190 - 198
  • [49] An additively manufactured titanium tilting suture anchor: a biomechanical assessment on human and ovine bone specimens
    Abedi, Ali
    Pourghazi, Farzad
    Eslami, Maysa
    Nabian, Mohammad Hossein
    Mohammadi, Ali Mohammad Ali
    Zanjani, Leila Oryadi
    Farahmand, Farzam
    FRONTIERS IN SURGERY, 2023, 10
  • [50] Arthroscopic glenoid labral lesion repair using all-suture anchor for traumatic anterior shoulder instability: short-term results
    Gul, Orkun
    Okutan, Ahmet Emin
    Ayas, Muhammet Salih
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (10) : 1991 - 1997