Biomechanical Evaluation of Proximal Hamstring Repair: All-Suture Anchor Versus Titanium Suture Anchor

被引:5
|
作者
Otto, Alexander [1 ,2 ,3 ]
DiCosmo, Alyssa M. [1 ]
Baldino, Joshua B. [1 ]
Mehl, Julian [1 ,2 ]
Obopilwe, Elifho [1 ]
Cote, Mark P. [1 ]
Imhoff, Andreas B. [1 ,2 ]
Beitzel, Knut [1 ,2 ,4 ]
Mazzocca, Augustus D. [1 ,2 ]
Coyner, Katherine [1 ,2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[2] Tech Univ Munich, Dept Orthopaed Sports Med, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
[4] ATOS Orthoparc Klin Koln, Cologne, Germany
关键词
proximal hamstring avulsion; hip; all-suture anchor; titanium suture anchor; biomechanics; proximal hamstring repair; SURGICAL REPAIR; AVULSION INJURIES; TENDON RUPTURES; OUTCOMES; SPORTS; ORIGIN; TAPE;
D O I
10.1177/2325967119892925
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal hamstring avulsions are severe tendon injuries and are commonly sports-related. Open and endoscopic techniques as well as different anchor configurations have already been described for proximal hamstring repair. Novel all-suture anchors have been developed to provide decreased bone loss during placement and reduced occupied bone volume when compared with titanium suture anchors. Hypothesis: Complete proximal hamstring avulsions repaired with all-suture anchors will demonstrate equal load to failure and comparable displacement under cyclic loading when compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Complete proximal hamstring avulsions were created in 18 paired cadaveric specimens (mean +/- SD age, 63.0 +/- 10.4 years). Either all-suture anchors or titanium suture anchors were used for repair. Cyclic loading from 10 to 125 N at 1 Hz was performed for 1500 cycles with a material testing machine. Displacement was assessed along anterior and posterior aspects of the tendon repair with optical tracking. Specimens were loaded to failure at a rate of 120 mm/min. Displacement, load to failure, and repair construct stiffness were compared between matched pairs with the Wilcoxon signed-rank test. Correlations were determined by Spearman rho analysis. Results: The all-suture anchors showed significantly higher load-to-failure values when compared with the titanium anchor repairs (799.64 +/- 257.1 vs 573.27 +/- 89.9 N; P = .008). There was no significant difference in displacement between all-suture anchors and titanium suture anchors at the anterior aspect (6.60 +/- 2.2 vs 5.49 +/- 1.1 mm; P = .26) or posterior aspect (5.87 +/- 2.08 vs 5.23 +/- 1.37 mm; P = .678) of the repaired hamstring tendons. Conclusion: All-suture anchors demonstrated similar displacement and superior load to failure when compared with titanium suture anchors.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Biomechanical Comparison of Knotless Anchor Repair Versus Simple Suture Repair for Type II SLAP Lesions
    Uggen, Christopher
    Wei, Anthony
    Glousman, Ronald E.
    ElAttrache, Neal
    Tibone, James E.
    McGarry, Michelle H.
    Lee, Thay Q.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (10) : 1085 - 1092
  • [22] Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor
    Dwyer, Tim
    Willett, Thomas L.
    Dold, Andrew P.
    Petrera, Massimo
    Wasserstein, David
    Whelan, Danny B.
    Theodoropoulos, John S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (02) : 357 - 364
  • [23] Biomechanical Characteristics of Suture Anchor Implants for Flexor Digitorum Profundus Repair
    Halat, Gabriel
    Negrin, Lukas
    Koch, Thomas
    Erhart, Jochen
    Platzer, Patrick
    Hajdu, Stefan
    Streicher, Johannes
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (02): : 256 - 261
  • [24] Fixation of the Proximal Hamstring Tendon Using an All-Suture Tensionable Knotless Technique
    Carbone, Andrew D.
    Saeed, Sheema K.
    Perez-Padilla, Paulo A.
    Domb, Benjamin G.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (07): : E1241 - E1246
  • [25] Complete proximal Hamstring Tendon Rupture Anchor based Mechanical Suture Technique for Reduction and Fixation
    Bauer, S.
    Riegger, M.
    Reichert, W.
    Blakeney, W. G.
    Haag, C.
    UNFALLCHIRURG, 2016, 119 (12): : 1043 - 1048
  • [26] Anatomic Suture Anchor Versus the Brostrom Technique for Anterior Talofibular Ligament Repair A Biomechanical Comparison
    Waldrop, Norman E., III
    Wijdicks, Coen A.
    Jansson, Kyle S.
    LaPrade, Robert F.
    Clanton, Thomas O.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (11) : 2590 - 2596
  • [27] THE 2.5 MM PUSHLOCK SUTURE ANCHOR SYSTEM VERSUS A TRADITIONAL SUTURE ANCHOR FOR ULNAR COLLATERAL LIGAMENT INJURIES OF THE THUMB: A BIOMECHANICAL STUDY
    Jarrett, C. D.
    Mcgillivary, G. R.
    Hutton, W. C.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (02) : 139 - 143
  • [28] A Meta-Analysis of Biomechanical Studies for Suture Button Pullout Versus Suture Anchor Repair of Flexor Digitorum Profundus Avulsions
    Imbergamo, Casey M.
    Sequeira, Sean B.
    Miles, Megan R.
    Means Jr, Kenneth R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (04): : 671 - 678
  • [29] Biomechanical Comparison of Coracoclavicular Fixation Using Metallic Versus All-Suture Anchors
    Hong, Chih-Kai
    Kuan, Fa-Chuan
    Hsu, Kai-Lan
    Chen, Yueh
    Chiang, Chen-Hao
    Su, Wei-Ren
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (01)
  • [30] Comparison of Suture Anchor Repair and Suture Tape Augmentation for Reconstruction of the Anterior Talofibular Ligament: A Biomechanical Study
    Shao, Qingfeng
    Hu, Dahai
    Chen, Xinru
    Wang, Huajun
    Xiao, Lei
    Teng, Qiang
    Hong, Jinsong
    Hou, Huige
    Zheng, Xiaofei
    ORTHOPAEDIC SURGERY, 2024, : 244 - 251