Ventilation efficiencies and thermal comfort results of a desk-edge-mounted task ventilation system

被引:38
|
作者
Faulkner, D [1 ]
Fisk, WJ [1 ]
Sullivan, DP [1 ]
Lee, SM [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Indoor Environm Dept, Environm Energy Technol Div, Berkeley, CA 94720 USA
关键词
improved IAQ practices and technologies; ventilation rates and strategies; offices; perceived air quality; thermal comfort;
D O I
10.1111/j.1600-0668.2004.00295.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In chamber experiments, we investigated the ventilation effectiveness and thermal comfort of a task ventilation system with an air supply nozzle located underneath the front edge of a desk and directing air towards a heated mannequin or a human volunteer seated at the desk. The task ventilation system provided outside air, while another ventilation system provided additional space cooling but no outside air. Test variables included the vertical angle of air supply (-15degrees to 45degrees from horizontal), and the supply flow rate of (3.5-6.5 l/s). Using the tracer gas step-up and step-down procedures, the measured air change effectiveness (i.e., exhaust air age divided by age of air in the breathing zone) in experiments with the mannequin ranged from 1.4 to 2.7 (median, 1.8), whereas with human subjects the air change effectiveness ranged from 1.3 to 2.3 (median, 1.6). The majority of the air change effectiveness values with the human subjects were less than values with the mannequin using comparable tests. Similarly, the tests run with supply air temperature equal to the room air temperature had lower air change effectiveness values than comparable tests with the supply air temperature lower (similar to5degreesC) than the room air temperature. The air change effectiveness values are higher than typically reported for commercially-available task ventilation or displacement ventilation systems. Based on surveys completed by the subjects, operation of the task ventilation system did not cause thermal discomfort.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [21] Personal cooling strategies to improve thermal comfort in warm indoor environments: Comparison of a conventional desk fan and air ventilation clothing
    Udayraj
    Li, Ziqi
    Ke, Ying
    Wang, Faming
    Yang, Bin
    ENERGY AND BUILDINGS, 2018, 174 : 439 - 451
  • [22] Desk fans for the control of the convection flow around occupants using ceiling mounted personalized ventilation
    Makhoul, A.
    Ghali, K.
    Ghaddar, N.
    BUILDING AND ENVIRONMENT, 2013, 59 : 336 - 348
  • [23] Comparison of chilled ceiling and mixing ventilation assisted by intermittent personalized ventilation: Thermal comfort and energy savings
    Al Assaad D.
    Ghali K.
    Ghaddar N.
    Renewable Energy and Power Quality Journal, 2020, 18 : 431 - 436
  • [24] Modelling natural ventilation for summer thermal comfort in Mediterranean dwellings
    Spentzou, Eftychia
    Cook, Malcolm J.
    Emmitt, Stephen
    INTERNATIONAL JOURNAL OF VENTILATION, 2019, 18 (01) : 28 - 45
  • [25] Indoor Thermal and Ventilation Indicator on University Students' Overall Comfort
    Jia, Lin-Rui
    Li, Qing-Yun
    Chen, Xi
    Lee, Chi-Chung
    Han, Jie
    BUILDINGS, 2022, 12 (11)
  • [26] Natural ventilation and thermal comfort investigation of a hawker center in Singapore
    Wong, NH
    Song, J
    Tan, GH
    Komari, BT
    Cheong, DKW
    BUILDING AND ENVIRONMENT, 2003, 38 (11) : 1335 - 1343
  • [27] Correlation of energy efficiency and thermal comfort depending on the ventilation strategy
    Baranova, Dania
    Sovetnikov, Daniil
    Semashkina, Dania
    Borodinecs, Anatolijs
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 503 - 510
  • [28] Influence of night natural ventilation on Tunisian summer thermal comfort
    Boukhris, Yosr
    Gharbi, Leila
    Ghrab-Morcos, Nadia
    2014 5TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2014,
  • [29] Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
    Daghigh, R.
    Adam, N. M.
    Sahari, B. B.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 113 - 122
  • [30] Basic study on the evaluation method of thermal comfort by cross ventilation
    Sato H.
    Akabayashi S.-I.
    Sakaguchi J.
    Kuwahara R.
    Journal of Environmental Engineering, 2010, 75 (647) : 59 - 66