Dynamic imaging of skeletal muscle contraction in three orthogonal directions

被引:62
作者
Lopata, Richard G. P. [1 ,3 ]
van Dijk, Johannes P. [2 ]
Pillen, Sigrid [2 ]
Nillesen, Maartje M. [1 ]
Maas, Huub [4 ]
Thijssen, Johan M. [1 ]
Stegeman, Dick F. [2 ,4 ]
de Korte, Chris L. [1 ]
机构
[1] Radboud Univ Nijmegen, Clin Phys Lab, Dept Pediat, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Ctr Neurosci, Dept Neurol,Med Ctr, NL-6500 HB Nijmegen, Netherlands
[3] Eindhoven Univ Technol, Cardiovasc Mech Grp, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[4] Vrije Univ Amsterdam, Fac Human Movement Sci, Res Inst, MOVE, Amsterdam, Netherlands
关键词
ultrasound; RF data; two-dimensional strain; biceps; nerve stimulation; ELASTOGRAPHY; ULTRASOUND; ELASTICITY; REVEALS; STRAINS; TENDON; MODEL;
D O I
10.1152/japplphysiol.00092.2010
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Lopata RG, van Dijk JP, Pillen S, Nillesen MM, Maas H, Thijssen JM, Stegeman DF, de Korte CL. Dynamic imaging of skeletal muscle contraction in three orthogonal directions. J Appl Physiol 109: 906-915, 2010. First published July 8, 2010; doi:10.1152/japplphysiol.00092.2010.-In this study, a multidimensional strain estimation method using biplane ultrasound is presented to assess local relative deformation (i.e., local strain) in three orthogonal directions in skeletal muscles during induced and voluntary contractions. The method was tested in the musculus biceps brachii of five healthy subjects for three different types of muscle contraction: 1) excitation of the muscle with a single electrical pulse via the musculocutaneous nerve, resulting in a so-called "twitch" contraction; 2) a train of five pulses at 10 Hz and 20 Hz, respectively, to obtain a submaximum tetanic contraction; and 3) voluntary contractions at 30, 60, and 100% of maximum contraction force. Results show that biplane ultrasound strain imaging is feasible. The method yielded adequate performance using the radio frequency data in tracking the tissue motion and enabled the measurement of local deformation in both the vertical direction (orthogonal to the arm) and in the horizontal directions (parallel and perpendicular to direction of the arm) in two orthogonal cross sections of the muscle. The twitch experiments appeared to be reproducible in all three directions, and high strains in vertical (25 to 30%) and horizontal (-20% to -10%) directions were measured. Visual inspection of both the ultrasound data, as well as the strain data, revealed a relaxation that was significantly slower than the force decay. The pulse train experiments nicely illustrated the performance of our technique: 1) similar patterns of force and strain waveforms were found; and 2) each stimulation frequency yielded a different strain pattern, e. g., peak vertical strain was 40% during 10-Hz stimulation and 60% during 20-Hz stimulation. The voluntary contraction patterns were found to be both practically feasible and reproducible, which will enable muscles and more natural contraction patterns to be examined without the need of electrical stimulation.
引用
收藏
页码:906 / 915
页数:10
相关论文
共 36 条
[1]  
Al-Chalabi Ammar, 2000, Current Opinion in Neurology, V13, P397, DOI 10.1097/00019052-200008000-00006
[2]   A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii [J].
Blemker, SS ;
Pinsky, PM ;
Delp, SL .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :657-665
[3]   Echo decorrelation from displacement gradients in elasticity and velocity estimation [J].
Céspedes, EI ;
de Korte, CL ;
van der Steen, AFW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (04) :791-801
[4]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[5]   Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle [J].
Chi, Sheng-Wei ;
Hodgson, John ;
Chen, Jiun-Shyan ;
Edgerton, V. Reggie ;
Shin, David D. ;
Roiz, Ronald A. ;
Sinha, Shantanu .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1243-1250
[6]  
D'hooge J, 2000, Eur J Echocardiogr, V1, P154, DOI 10.1053/euje.2000.0031
[7]   Assessment of the mechanical properties of the musculoskeletal system using 2-D and 3-D very high frame rate ultrasound [J].
Deffieux, Thomas ;
Gennisson, Jean-Luc ;
Tanter, Mickael ;
Fink, Mathias .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (10) :2177-2190
[8]  
Dresner MA, 2001, J MAGN RESON IMAGING, V13, P269, DOI 10.1002/1522-2586(200102)13:2<269::AID-JMRI1039>3.0.CO
[9]  
2-1
[10]   SKELETAL-MUSCLE CONTRACTION IN HEALTHY-VOLUNTEERS - ASSESSMENT WITH DOPPLER TISSUE IMAGING [J].
GRUBB, NR ;
FLEMING, A ;
SUTHERLAND, GR ;
FOX, KAA .
RADIOLOGY, 1995, 194 (03) :837-842