Indirect determination of cysteine in pharmaceutical formulations by high-resolution continuum source graphite furnace molecular absorption spectrometry

被引:8
作者
Almeida, Jorge S. [1 ,2 ]
Meira, Lucilia A. [1 ]
Teixeira, Leonardo S. G. [1 ,2 ]
机构
[1] Univ Fed Bahia, Inst Quim, Dept Quim Analit, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
[2] Univ Fed Bahia, INCT Energia & Ambiente, Inst Quim, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
关键词
Cysteine; Carbon monosulfide molecule; Sum of absorption molecular lines; Pharmaceutical formulations; Amino acids; High-resolution continuum source graphite furnace molecular absorption spectrometry; AIR-ACETYLENE FLAME; SEQUENTIAL DETERMINATION; SULFUR DETERMINATION; PALLADIUM NANOPARTICLES; CARBON MONOSULFIDE; CHEMICAL MODIFIER; FUEL SAMPLES; CS MOLECULE; PHOSPHORUS; STRATEGIES;
D O I
10.1016/j.microc.2018.07.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An indirect method for the determination of cysteine in pharmaceutical formulations involving the monitoring of CS (carbon monosulfide) molecular absorption bands using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) is reported. The best conditions for the determination were based on the sum of the absorbance signals of the molecular transition lines for CS at 258.034 and 258.056 nm with a pyrolysis temperature of 1000 degrees C and a volatilization temperature of 2400 degrees C using Pd/Mg as a chemical modifier. The linear range for cysteine was 1.4 to 100 mg kg(-1) with a limit of detection and limit of quantification of 0.4 and 1.3 mg kg(-1), respectively. The precision, evaluated as relative standard deviation (RSD), was 3.7% (n = 10) for a sample containing 25.0 mg kg(-1) of cysteine. The accuracy of sulfur determination was evaluated using a standard reference material (NIST-SRM-1573a tomato leaves) and concordant values were observed within the 95% confidence interval. The method was successfully applied to the analysis of pharmaceutical formulation samples containing cysteine, lysine, and alanine. The concentrations of cysteine found in the samples were between 9.8 and 20.1 mg kg(-1).
引用
收藏
页码:155 / 159
页数:5
相关论文
共 41 条
[1]   Sequential determination of cadmium and lead in organic pharmaceutical formulations using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Aleluia, Augusto C. M. ;
de Santana, Fernanda A. ;
Brandao, Geovani C. ;
Ferreira, Sergio L. C. .
MICROCHEMICAL JOURNAL, 2017, 130 :157-161
[2]   Multivariate optimization of ultrasound-assisted extraction using Doehlert matrix for simultaneous determination of Fe and Ni in vegetable oils by high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Almeida, Jorge S. ;
Santos, Gabriel L. ;
Brandao, Geovani C. ;
Korn, Maria G. A. ;
Teixeira, Leonardo S. G. .
FOOD CHEMISTRY, 2019, 273 :130-135
[3]   Determination of Pb, Cu and Fe in ethanol fuel samples by high-resolution continuum source electrothermal atomic absorption spectrometry by exploring a combination of sequential and simultaneous strategies [J].
Almeida, Jorge S. ;
Souza, Odara C. C. O. ;
Teixeira, Leonardo S. G. .
MICROCHEMICAL JOURNAL, 2018, 137 :22-26
[4]  
Almeida JS, 2016, ANAL METHODS-UK, V8, P3249, DOI [10.1039/C6AY00165C, 10.1039/c6ay00165c]
[5]  
Araujo R. G. O., 2012, MICROCHEM J, V1, P1
[6]   Quantitative determination of sulfur by high-resolution graphite furnace molecular absorption spectrometry [J].
Baumbach, Gisa ;
Limburg, Tobias ;
Einax, Juergen W. .
MICROCHEMICAL JOURNAL, 2013, 106 :295-299
[7]   A practical method for the determination of sulphur in coal samples by high-resolution continuum source flame atomic absorption spectrometry [J].
Baysal, A. ;
Akman, S. .
TALANTA, 2011, 85 (05) :2662-2665
[8]   Diurnal variation in glutathione and cysteine redox states in human plasmas [J].
Blanco, Roberto A. ;
Ziegler, Thomas R. ;
Carlson, Bowe A. ;
Cheng, Po-Yung ;
Park, Youngja ;
Cotsonis, George A. ;
Accardi, Carolyn Jonas ;
Jones, Dean P. .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2007, 86 (04) :1016-1023
[9]   Fluorine in eye shadow: Development of method using high-resolution continuum source graphite furnace molecular absorption spectrometry via calcium mono-fluoride with direct solid sample introduction [J].
Borges, Aline R. ;
Duarte, Alvaro T. ;
Potes, Mariana da L. ;
Silva, Marcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard .
MICROCHEMICAL JOURNAL, 2016, 124 :410-415
[10]   Molecular absorption spectrometry in flames and furnaces: A review [J].
Butcher, David J. .
ANALYTICA CHIMICA ACTA, 2013, 804 :1-15