A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging

被引:0
|
作者
Sahbaee, Pooyan [1 ,2 ]
Abadi, Ehsan [2 ,4 ]
Sanders, Jeremiah [2 ,3 ]
Becchetti, Marc [2 ,3 ]
Zhang, Yakun [2 ]
Agasthya, Greeshma [2 ]
Segars, Paul [2 ,3 ]
Samei, Ehsan [2 ,3 ,4 ]
机构
[1] N Carolina State Univ, Dept Phys, Raleigh, NC 27695 USA
[2] Duke Univ, Dept Radiol, Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[4] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27705 USA
关键词
Computed Tomography; Contrast Material; Compartmental Model; Contrast Enhanced; Patient Specific; Iodine; Radiation dose; CTDI; Image Quality; DOUBLE-STRAND BREAKS; REPAIR;
D O I
10.1117/12.2216516
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study was to substantiate the interdependency of image quality, radiation dose, and contrast material dose in CT towards the patient-specific optimization of the imaging protocols. The study deployed two phantom platfouns. First, a variable sized phantom containing an iodinated insert was imaged on a representative CT scanner at multiple CTDI values. The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast to noise ratio (CNR), was calculated for different iodine-concentration levels. Second, the analysis was extended to a recently developed suit of 58 virtual human models (5D-XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was "imaged" using a CT simulation platfoun. 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The Sensitivity of Ratio (SR), defined as ratio of change in iodine-concentration versus dose to yield a constant change in CNR was calculated and compared at high and low radiation dose for both phantom platfouns. The results show that sensitivity of CNR to iodine concentration is larger at high radiation dose (up to 73%). The SR results were highly affected by radiation dose metric; CTDI or organ dose. Furthermore, results showed that the presence of contrast material could have a profound impact on optimization results (up to 45%).
引用
收藏
页数:8
相关论文
共 50 条
  • [21] RADIATION DOSE AND IMAGE QUALITY IN PEDIATRIC HEAD CT
    Spampinato, Maria Vittoria
    Stalcup, Seth
    Matheus, Maria Gisele
    Byington, Kathleen
    Tyler, Michael
    Bickley, Stetson
    Tipnis, Sameer
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 310 - 316
  • [22] Radiation dose reduction in extremity multi-detector CT: A comparison of image quality with a standard dose protocol
    Kim, Ji Na
    Park, Hee Jin
    Kim, Myung Sub
    Kook, Shin Ho
    Ham, Soo Youn
    Kim, Eugene
    Park, Se Jin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [23] Radiation dose and image quality optimisation in medical imaging
    Hogg, Peter
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (03) : 236 - 237
  • [24] Radiation dose and image quality in pediatric bitewing imaging
    Rajalingam, Raheis
    Brage, Karen
    Nielsen, Louise Kjaerby
    Eriksen, Freja Bogh
    Jorgensen, Helene Hviid
    Mikkelsen, Anne Sofie
    Scholer, Gitte
    Mekis, Nejc
    Bruvo, Maja
    Precht, Helle
    RADIATION PROTECTION DOSIMETRY, 2024, 201 (02) : 113 - 121
  • [25] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [26] Image quality and radiation dose of low-tube-voltage CT with reduced contrast media for right adrenal vein imaging
    Takahashi, Yuki
    Ota, Hideki
    Omura, Kensuke
    Dendo, Yutaka
    Otani, Katharina
    Matsuura, Tomonori
    Kitami, Masahiro
    Seiji, Kazumasa
    Tezuka, Yuta
    Nezu, Masahiro
    Ono, Yoshikiyo
    Morimoto, Ryo
    Satoh, Fumitoshi
    Takase, Kei
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 150 - 157
  • [27] Pilot Study on Image Quality and Radiation Dose of CT Colonography with Adaptive Iterative Dose Reduction Three-Dimensional
    Shen, Hesong
    Liang, Dan
    Luo, Mingyue
    Duan, Chaijie
    Cai, Wenli
    Zhu, Shanshan
    Qiu, Jianping
    Li, Wenru
    PLOS ONE, 2015, 10 (01):
  • [28] A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
    Crawley, MT
    Booth, A
    Wainwright, A
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883): : 607 - 614
  • [29] Image optimization and reduction of radiation dose in CT of the paranasal sinuses
    Davoudi, Mohammad
    Lotfian Ahangarkolaei, Shaghayegh
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [30] Reduction of radiation dose in PET-CT: Low dose protocols and image quality
    Kim, Hyeon Sik
    Sheen, Heesoon
    Jung, Sung Pil
    Hong, Seon Pyo
    Byun, Byung-Hyun
    Min, Jung-Joon
    Lee, Byeong-il
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52